Viqua S2Q-PV Owner'S Manual Download Page 3

Safety Information

3

Section 1

Safety Information

These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all 

danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to 

the equipment.
Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any 

manner other than that specified in the installation manual.

1.1 Potential Hazards:

Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.

1.2 Safety Precautions:

Waste electrical and electronic equipment (WEEE). This symbol 
indicates that you should not discard wasted electrical or electronic 
equipment (WEEE) in the trash. For proper disposal, contact your local 
recycling/reuse or hazardous waste center.

This symbol indicates not to store any combustible or flammable 
material close to the system.

This symbol indicates there is Mercury present.

This symbol indicates that the contents of the transport package are 
fragile and the package should be handled with care.

This is the safety alert symbol. Obey all safety messages that follow this 
symbol to avoid potential injury. When on the equipment, refer to the 
Operational and Maintenance manual for additional safety information.

This symbol indicates safety glasses with side protection is required 
for protection against UV exposure.

This symbol indicates a risk of electrical shock and/or electrocution 
exists.

This symbol indicates gloves must be worn.

This symbol indicates the marked equipment may contain a component 
that can eject forcibly. Obey all procedures to safely depressurize.

This symbol indicates safety boots must be worn.

This symbol indicates the marked item could inject fluid into the skin.

This symbol indicates the operator must read all available 
documentation to perform required procedures.

This symbol indicates there is a potential UV hazard. Proper protection 
must be worn.

This symbol indicates the plumber must use copper piping.

This symbol indicates the marked item could be hot and should not be 
touched without care.

This symbol indicates that the system should only be connected to a 
properly grounded, grounding-type controller receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI).

This symbol indicates there is a potential for VERY hot water when flow 
is started.

D A N G E R

Failure to follow these instructions will result in serious injury or death.

  •

Electric Shock:

 To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a 

situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself, 

refer to an authorized service facility.

  •

GROUNDING: 

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric 

current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. 

The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. 

Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service 

personnel if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system – if it does not fit in 

the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system.

  •

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

: To comply with the National Electrical Code (NFPA 70) and to provide additional 

protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is 

protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 

30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule.

  •

DO NOT operate the disinfection system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner.

  •

DO NOT use this disinfection system for other than intended use (potable water applications). The use of attachments not recommended or sold by 

the manufacturer / distributor may cause an unsafe condition.

  •

DO NOT install this disinfection system where it will be exposed to the weather or to temperatures below freezing.

  •

DO NOT store this disinfection system where it will be exposed to the weather.

  •

DO NOT store this disinfection system where it will be exposed to temperatures below freezing unless all water has been drained from it and the 
water supply has been disconnected.

Hg

UV

Cu

Summary of Contents for S2Q-PV

Page 1: ...ario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models S2Q PV S5Q PV S5Q PV ASPL Owner s Manual Powered by 520026_RevM ...

Page 2: ...hy should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equipment An increasing number of calls to VIQUA Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safe...

Page 3: ...GFCI This symbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situation is encountered that is explicitly addressed by the provided maintenance and trou...

Page 4: ...ry If the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guidelines for the removal and disposal of mercury waste NOTICE The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours To ensur...

Page 5: ...tems 2 Spring SP008 Used on all systems 3 Chamber Used on all systems 4 Connector base 270276 Used on all systems 5 Open Ended 214 fused quartz sleeves with fire polished ends QS 330 S2Q PV QS 463 S5Q PV ASPL S5Q PV 6 O ring 410867 R Used on all systems 7 Retaining nut RN 001 Used on all systems 8 Hard glass coated Sterilume EX UV lamps for long consistent life 9000 hours S330RL S2Q PV S463RL S5Q ...

Page 6: ...l fire hazard Drip loops in all cordage connected to controller is highly recommended The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination The disinfection system is intended for indoor use only Do not install disinfection system where it may be exposed to the weather ...

Page 7: ...n power must be removed for 30 seconds to allow ballast to reset 2 As the system requires time to reach its full operating capacity please allow the disinfection system to operate 3 5 minutes prior to using the water from the unit In addition to clear any air or debris from the system allow water to run through the disinfection system for 2 3 minutes when using an RO application run the water for ...

Page 8: ... allow the unit to cool for 10 minutes 3 1 2 Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector 4 Hg UV Remove the UV lamp in upward direction from the chamber and lamp connector base Hold the UV lamp at the ceramic ends 5 Hg UV 1 2 Insert the new lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber 6 Attach the conn...

Page 9: ...using the drain port 2 1 2 3 Remove the bottom retaining nut floating spring and O ring 3 1 2 Remove the top retaining nut and O ring 4 Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water 6 Reinstall the quartz sleeve in the UV chamber allowing the sleeve to protrude an equal distance at both ends of the ...

Page 10: ...rews and plug the connector back onto the ballast Alarm side Section 5 Specifications C A U T I O N Ensure Alarm connector is connected to the Alarm side of the Ballast Model S2Q PV S5Q PV S5Q PV ASPL Flow Rate 1 US Public Health 16mJ cm2 5 gpm 19 lpm 0 9 m3 hr 11 gpm 42 lpm 2 5 m3 hr 11 gpm 42 lpm 2 5 m3 hr Standard 30 mJ cm2 3 gpm 11 lpm 0 7 m3 hr 6 gpm 23 lpm 1 4 m3 hr 6 gpm 23 lpm 1 4 m3 hr NS...

Page 11: ...r Electrical and Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year L...

Page 12: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com ...

Reviews: