Viqua S2Q-PV Owner'S Manual Download Page 4

Safety Information

4

1.3 Water Chemistry

Water quality is extremely important for the optimum performance of your UV system. The following levels are 

recommended for installation:

* Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned 

periodically. If total hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess 

of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of 

WA R N I N G

  •

During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is 
recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To 
eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.

  •

Do not pass water through the UV system for a minimum of 5 minutes after applying power (including after power interruptions) to avoid passing 
under-treated water that may, in rare instances, pose health hazards.

  •

This system contains a UV Lamp. Do not operate the UV Lamp when it is removed from the chamber. Unintended use or damage of the system 
may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin.

  •

Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void 
the manufacturer's warranty.

WARNING:

 This product can expose you to chemicals including phthalates, which is known to the state of California to cause cancer, and mercury, 

which is known to the State of California to cause birth defects or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov

.

C A U T I O N

Failure to follow these instructions could result in minor or moderate injury.

  •

Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the 
controller or lamp connector.

  •

Due to thermal expansion concerns and potential material degradation due to UV exposure, it is recommended to use metal fittings and at least 
10" of copper pipe on the outlet of your UV chamber.

  •

Hg EXPOSURE

: The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes 

and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for 
the removal and disposal of mercury waste.

N O T I C E

  •

The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the 
UV lamp annually.

  •

The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience 
and knowledge, are also not to handle the UV system unless they have been given supervision or instruction. 

  •

This system is intended to be permanently connected to the water lines.

  •

This system is not intended to be used in or above water or outdoors or used in swimming pools when persons are in the pool.

  •

EXTENSION CORDS

: If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord 

connectors that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an 
electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat. Exercise 
caution when arranging the cord so that it will not be tripped over or pulled. DO NOT use damaged extension cords. Examine extension cord 
before using and replace if damaged. DO NOT abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect 
the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always 
grasp the plug and pull to disconnect.

  •

If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

  •

SYSTEM PROTECTION

: To protect your Controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is strongly 

recommended.

  •

The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title 21, 
Chapter 1, Subchapter J, Radiological Health. 

  •

Read and understand the Owner’s Manual before operating and performing any maintenance on this equipment.

Water Quality and Minerals

Level

Iron

< 0.3 ppm (0.3 mg/L)

Hardness*

< 7 gpg (120 mg/L)

Turbidity

< 1 NTU

Manganese

< 0.05 ppm (0.05 mg/L)

Tannins

< 0.1 ppm (0.1 mg/L)

UV Transmittance

> 75% (call factory for recommendations on applications where UVT < 75%)

UV

Hg

Summary of Contents for S2Q-PV

Page 1: ...ario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models S2Q PV S5Q PV S5Q PV ASPL Owner s Manual Powered by 520026_RevM ...

Page 2: ...hy should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equipment An increasing number of calls to VIQUA Technical Support are connected with non genuine lamps being used unknowingly as replacements Damage arising from the use of non genuine lamps poses a safe...

Page 3: ...GFCI This symbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electric shock special care should be taken since water is present near the electrical equipment Unless a situation is encountered that is explicitly addressed by the provided maintenance and trou...

Page 4: ...ry If the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guidelines for the removal and disposal of mercury waste NOTICE The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours To ensur...

Page 5: ...tems 2 Spring SP008 Used on all systems 3 Chamber Used on all systems 4 Connector base 270276 Used on all systems 5 Open Ended 214 fused quartz sleeves with fire polished ends QS 330 S2Q PV QS 463 S5Q PV ASPL S5Q PV 6 O ring 410867 R Used on all systems 7 Retaining nut RN 001 Used on all systems 8 Hard glass coated Sterilume EX UV lamps for long consistent life 9000 hours S330RL S2Q PV S463RL S5Q ...

Page 6: ...l fire hazard Drip loops in all cordage connected to controller is highly recommended The complete water system including any pressure or hot water tanks must be sterilized before start up by flushing with chlorine household bleach to destroy any residual contamination The disinfection system is intended for indoor use only Do not install disinfection system where it may be exposed to the weather ...

Page 7: ...n power must be removed for 30 seconds to allow ballast to reset 2 As the system requires time to reach its full operating capacity please allow the disinfection system to operate 3 5 minutes prior to using the water from the unit In addition to clear any air or debris from the system allow water to run through the disinfection system for 2 3 minutes when using an RO application run the water for ...

Page 8: ... allow the unit to cool for 10 minutes 3 1 2 Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector 4 Hg UV Remove the UV lamp in upward direction from the chamber and lamp connector base Hold the UV lamp at the ceramic ends 5 Hg UV 1 2 Insert the new lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber 6 Attach the conn...

Page 9: ...using the drain port 2 1 2 3 Remove the bottom retaining nut floating spring and O ring 3 1 2 Remove the top retaining nut and O ring 4 Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water 6 Reinstall the quartz sleeve in the UV chamber allowing the sleeve to protrude an equal distance at both ends of the ...

Page 10: ...rews and plug the connector back onto the ballast Alarm side Section 5 Specifications C A U T I O N Ensure Alarm connector is connected to the Alarm side of the Ballast Model S2Q PV S5Q PV S5Q PV ASPL Flow Rate 1 US Public Health 16mJ cm2 5 gpm 19 lpm 0 9 m3 hr 11 gpm 42 lpm 2 5 m3 hr 11 gpm 42 lpm 2 5 m3 hr Standard 30 mJ cm2 3 gpm 11 lpm 0 7 m3 hr 6 gpm 23 lpm 1 4 m3 hr 6 gpm 23 lpm 1 4 m3 hr NS...

Page 11: ...r Electrical and Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year L...

Page 12: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com ...

Reviews: