5
3.0 S
YSTEM
O
VERVIEW
3.1
4-Log Virus Reduction
The PRO24-186 system provides over 186 mJ/cm
2
UV dose for 4-log reduction of
viruses, including the Adenovirus. The system consists of two chambers in series
utilizing amalgam UV lamps, CoolTouch
TM
, and LightWise
TM
technology. The
Adenovirus system is fully third-party validated to USEPA UV Disinfection Guidance
Manual (UVDGM) protocol for 4-log Adenovirus reduction. In addition to the virus
reduction, each of the chambers has been validated to provide 4-log reduction of
Cryptosporidium and Giardia.
Benefits
•
Ultra-high output amalgam lamp technology allows for compact installation.
•
Intense disinfection dose reduces or removes the need for chemical treatment.
•
Real-time UV intensity and flow rate sensor activate visual and audible controller
alarm.
3.2
Pressure Drop
The pressure drop across the system is proportional to the flow through the system.
0
5
10
15
20
25
30
35
0
5
10
15
20
25
P
ressu
re
D
ro
p
(
p
si
)
Flow rate (gpm)