![Viqua Adenovirus PRO24-186 User Manual Download Page 4](http://html.mh-extra.com/html/viqua/adenovirus-pro24-186/adenovirus-pro24-186_user-manual_1029847004.webp)
1
1.0 P
ROJECT
&
S
YSTEM
D
ESCRIPTION
1.1
Project Description
Project Name
Guidelines
Maximum flow rate
24 GPM (91 l/min) at 95% UVT
Design dose
186 mJ/cm
2
Operating pressure
15 psi (103 kPa) - 125 psi (862 kPa)
Ambient air temp.
0°C (32°F) - 40°C (104°F)
Ambient water temp.
1°C (35.6°F) - 45°C (104°F)
Hardness
120 ppm (7 grains / gallon) max.*
Manganese content
0.05 ppm max.*
Iron content
0.3 ppm max.*
UVT
75% min.*
*
after pretreatment
1.2
System Description
Model
PRO24-186
Spare Parts
Quantity
Quantity
Lamps
Sleeves
Chamber
Material
316L SST
UV sensors
Dimensions
41” x 4” (103 x 10 cm)
Flow Meters
Inlet & outlet ports
Combo 1-1/4" MNPT, 1"
FNPT
CoolTouch
™
Fans
UL Certified burst
pressure
300 psi (2,067 kPa)
COMMcenters
™
Orientation
Vertical
Electrical
Optional Accessories
Quantity
Power Supply
13” x 6.5” (33 x 16.5 cm)
Solenoid valve
Voltage
100 - 240 V AC
4-20 mA Interface
Frequency
50 - 60 Hz
Max. current
5 Amps
Max. power
consumption
460 Watts
Lamp power
400 Watts