Chapter 4 Configuration with Siemens TIA Portal
Manual VIPA System 200V
4-6
HB97E - CPU - RE_21x-1Bx06 - Rev. 13/20
To be compatible with the Siemens TIA Portal the VIPA CPU is to be
configured as
CPU 315-2DP (6ES7 315-2AG10-0AB0 V2.6)
from
Siemens.
The evolvement of the CPU 21x takes place as a virtual PROFIBUS master
system with the following proceeding:
•
Start the Siemens TIA Portal.
•
Create a new project in the
Portal view
with
Create new project
.
•
Change to the
Project view.
•
Click in the
Project tree
at
Add new device
.
•
Select the following CPU in the input dialog:
SIMATIC S7-300 > CPU 315-2DP > 6ES7 315-2AG10-0AB0 V2.6.
Then the CPU is inserted with a profile rail.
Project area:
1
2
4
5
6
7
Device overview:
Module ...
Slot
...
Type
...
PLC...
2
CPU
315-2DP
MPI interface...
2 0
MPI interface..
DP interface...
2 X2
DP interface...
...
Since the CPU from VIPA is configured as Siemens CPU, so the
parameterization takes place via the Siemens CPU.
For parameterization click in the
Project area
respectively in the
Device
overview
at the CPU part. Then the parameters of the CPU part are shown
in the
Properties
dialog. Here you can make your parameter settings.
Note!
The parameters are described in chapter "Deployment CPU..." at "CPU
parameterization".
Proceeding
Parameterization
Summary of Contents for CPU 214
Page 1: ...VIPA System 200V CPU Manual HB97E_CPU RE_21x 1Bx06 Rev 13 20 May 2013...
Page 4: ...Contents Manual VIPA System 200V ii HB97E CPU RE_21x 1Bx06 Rev 13 20...
Page 8: ...Safety information Manual VIPA System 200V 4 HB97E CPU RE_21x 1Bx03 Rev 13 20...
Page 26: ...Chapter 1 Basics and Assembly Manual VIPA System 200V 1 18 HB97E CPU RE_21x 1Bx06 Rev 13 20...