Unpack the Griddle immediately after receipt. Remove the Gas Griddle from the crate; remove all packaging 

on and surrounding the unit and be certain to remove all protective plastics and residues from all surfaces. 

Make sure that all parts provided are located. Equipment must have the legs properly installed before use. 

Before using this equipment it must be cleaned and dried thoroughly. 

INSTALLATION 

NOTE: it is vital that the purchaser of this equipment post in a prominent location instructions to be followed in 

the event that the user smells gas. This information shall be obtained by consulting the local gas supplier. The 

purchaser of this equipment must post in a prominent location. 

1.

Read this manual thoroughly before installation and operation. DO NOT proceed with installation and

operation if you have any questions or do not understand anything in this manual. Contact your local

representative or 

VIONET

 first.

2.

Select a location for the Griddle that has a level, solid, nonskid surface that is nonflammable and

 

away

from water hazards or sinks, and is in a well-lighted work area away from children and visitors.

3.

This equipment but be installed under a proper ventilation as required by local code.

Local codes regarding installation and ventilation vary greatly by area. The National

 

Fire

Protection Association states in its NFPA 96 latest edition (see NFPA page at the

 

beginning of

this manual) that local codes are “authority having jurisdiction” when it comes to

requirements for installation of equipment. Therefore, installation should comply with all local

codes.

4.

Screw legs into (A) the permanently fastened nuts on the four corners of the unit and tighten by hand.

Legs must be installed to adequately provide proper ventilation to the unit.

5.

Level unit by adjusting the four feet and tighten securely. The adjustable feet have an adjustment of

one inch. Do not slide unit with legs mounted. Lift if necessary to move unit.

6.

The supplied gas pressure regulator is factory set at 4” Natural Gas W.C. or 10” Propane Gas.

7.

THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACE ONLY.

Noncombustible clearances: 6” sides (152 mm), 6” rear (152 mm), 4” floor (102 mm).

8.

Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the unit

by the flue. Do not place objects between the bottom of the unit and the counter top.

9.

There must be adequate clearance for removal of the front panel. All major parts except the burners

are removable through the front if the gas is disconnected.

10.

It may be necessary to adjust the balance of gas volume and air supply to each burner. This must be

done by and authorized service technician.

11.

Pipe threading compound must be resistant to the action of liquefied petroleum gas. DO NOT USE

TEFLON TAPE.

The installation of this appliance must conform to local codes, or In the absence of local codes, the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA 

B149.1, as applicable. 

The appliance and its individual shut off valve must be disconnected from the gas supply piping

system during any pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual

shut off valve during any pressure testing of the gas supply piping system at test pressures equal to

less than ½ PSI (3.5kPa).

 

DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap 

and water solution before operating the unit.

 

As continued product improvement is a policy of Vionet, specifications are subject to change.

8830 Siempre Viva Road Suite 100  |  San Diego CA 92154  |  

https://www.vionetequipment.com

Summary of Contents for GAS COUNTER SERIES

Page 1: ...nance Failure to comply with regular maintenance guidelines out lined in the manual may void the warranty Improper installation adjustment alteration service or maintenance can cause property damage i...

Page 2: ...he vicinity of this or any other appliance Keep area around appliances free and clear of combustibles Purchaser of equipment must post in a prominent location detailed instructions to be followed in t...

Page 3: ...as by a licensed and certified gas technician Documentation may be necessary for warranty issues Failure to comply with this instruction will void warranty Unit installation must conform to the Nation...

Page 4: ...Description BTU hr Number of Burners Gas Type VIOGR24 VIOGR24T Gas Griddle 24 60 000 2 Natural Gas or Propane VIOGR36 VIOGR36T Gas Griddle 36 90 000 3 Natural Gas or Propane VIOGR48 VIOGR48T Gas Gridd...

Page 5: ...ilation to the unit 5 Level unit by adjusting the four feet and tighten securely The adjustable feet have an adjustment of one inch Do not slide unit with legs mounted Lift if necessary to move unit 6...

Page 6: ...or vice versa may only be performed by the factory or its authorized service agent In the case of troubleshooting endure that the correct orifice sizes of the spuds have been provided Natural Gas Ori...

Page 7: ...the pilot flames as small as possible but high enough to light the burner immediately when burner valve is turned to the HIGH setting Access to the pilot flame adjustment screw is obtained by removin...

Page 8: ...utting procedures used to manufacture these items result in sharp edges These sharp edges are removed to the best of our ability however we insist the operator take care when in contact with this piec...

Page 9: ...sired flame height is all that is required to put the unit in service Igniting the Burner To ignite the burner turn knob to the ON position then back off to the desired flame level The range of adjust...

Page 10: ...Operated Griddles there is NO TEMPERATURE CONTROL you the operator must maintain temperature by increasing or decreasing the flame height as required Each valve controls the gas flow to the burner to...

Page 11: ...ce with a grill pad or metal spatula Clean the griddle surface thoroughly If necessary use a griddle stone or grill pad If a griddle stone is not used correctly it will damage the Griddle surface Rub...

Page 12: ...gnite anything or turn switch on anything electrical Call Fire department if needed and call for service Check to see if burners and pilots are lit If not turn off all burner valves and main gas valve...

Page 13: ...Description Ref Part Description 1 GC10001 U SHAPED BURNER 8 GC10008 ADJUSTABLE LEG 2 GC10002 FIXED PLATE PILOT 9 GC10009 ORIFICE 3 GC10003 PILOT 10 GC10010 KNOB 4 GC10004 GAS VALVE 11 GC10011 PILOT...

Page 14: ...ement parts and occasional professional service may be necessary to extend the useful life of this unit When service is needed contact a VIONET Authorized Service Agency or your dealer To avoid confus...

Reviews: