background image

SAFETY PRECAUTIONS 

Before installing and operating this equipment, be sure everyone involved in its operation is fully trained 

and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules 

and precautions. 

The following symbols, found throughout this manual, alert you to potentially dangerous conditions to 

the operator, service personnel, or to the equipment. 

This symbol refers to a potential hazard or unsafe practice that could result 

in injury or death. 

This symbol refers to a potential hazard or unsafe practice that could result 

in injury, product damage, or property damage. 

NOTICE 

This symbol refers to information that needs special attention or must be 

fully understood, even though not dangerous. 

FOR YOUR SAFETY TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE: 

ALWAYS 

install equipment in a work area with adequate light and space.

ONLY 

operate on a solid, level, nonskid surface that is nonflammable and away from sinks and

water hazards.

NEVER

 bypass, alter, or modify this equipment in any way from its original condition. Doing so

may create hazards and will void warranty.

FIRE HAZARD FOR YOUR SAFETY 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 

Keep area around appliances free and clear of combustibles. 

Purchaser of equipment must post in a prominent location, detailed instructions to be followed in the event 

the operator smells gas. Obtain the instructions from the local gas supplier 

VIONET

 

Griddles are intended for commercial use only. Not for household use. 

Warranty will be void if service work is performed by other than an authorized technician, or if other than 

genuine 

VIONET

 replacement parts are installed. 

Be sure this Operator’s/Installer’s Manual and important papers are given to the proper authority to retain for 

future reference. 

Congratulations! You have purchased one of the finest pieces of commercial cooking equipment on the 

market. You will find that your new equipment, like all 

VIONET

 equipment, has been designed and 

manufactured to meet the toughest standards in the industry. Each piece of 

VIONET

 equipment is carefully 

engineered and designs are verified through laboratory tests and field installations. With proper care and field 

maintenance, you will experience years of reliable, trouble-free operation. For best results, read this manual 

carefully. 

RETAIN THIS MANUAL FOR FURTURE REFERECE 

Owner’s/Installer Manual Rev 1E 

As continued product improvement is a policy of Vionet, specifications are subject to change.

8830 Siempre Viva Road Suite 100  |  San Diego CA 92154  |  

https://www.vionetequipment.com

Summary of Contents for GAS COUNTER SERIES

Page 1: ...nance Failure to comply with regular maintenance guidelines out lined in the manual may void the warranty Improper installation adjustment alteration service or maintenance can cause property damage i...

Page 2: ...he vicinity of this or any other appliance Keep area around appliances free and clear of combustibles Purchaser of equipment must post in a prominent location detailed instructions to be followed in t...

Page 3: ...as by a licensed and certified gas technician Documentation may be necessary for warranty issues Failure to comply with this instruction will void warranty Unit installation must conform to the Nation...

Page 4: ...Description BTU hr Number of Burners Gas Type VIOGR24 VIOGR24T Gas Griddle 24 60 000 2 Natural Gas or Propane VIOGR36 VIOGR36T Gas Griddle 36 90 000 3 Natural Gas or Propane VIOGR48 VIOGR48T Gas Gridd...

Page 5: ...ilation to the unit 5 Level unit by adjusting the four feet and tighten securely The adjustable feet have an adjustment of one inch Do not slide unit with legs mounted Lift if necessary to move unit 6...

Page 6: ...or vice versa may only be performed by the factory or its authorized service agent In the case of troubleshooting endure that the correct orifice sizes of the spuds have been provided Natural Gas Ori...

Page 7: ...the pilot flames as small as possible but high enough to light the burner immediately when burner valve is turned to the HIGH setting Access to the pilot flame adjustment screw is obtained by removin...

Page 8: ...utting procedures used to manufacture these items result in sharp edges These sharp edges are removed to the best of our ability however we insist the operator take care when in contact with this piec...

Page 9: ...sired flame height is all that is required to put the unit in service Igniting the Burner To ignite the burner turn knob to the ON position then back off to the desired flame level The range of adjust...

Page 10: ...Operated Griddles there is NO TEMPERATURE CONTROL you the operator must maintain temperature by increasing or decreasing the flame height as required Each valve controls the gas flow to the burner to...

Page 11: ...ce with a grill pad or metal spatula Clean the griddle surface thoroughly If necessary use a griddle stone or grill pad If a griddle stone is not used correctly it will damage the Griddle surface Rub...

Page 12: ...gnite anything or turn switch on anything electrical Call Fire department if needed and call for service Check to see if burners and pilots are lit If not turn off all burner valves and main gas valve...

Page 13: ...Description Ref Part Description 1 GC10001 U SHAPED BURNER 8 GC10008 ADJUSTABLE LEG 2 GC10002 FIXED PLATE PILOT 9 GC10009 ORIFICE 3 GC10003 PILOT 10 GC10010 KNOB 4 GC10004 GAS VALVE 11 GC10011 PILOT...

Page 14: ...ement parts and occasional professional service may be necessary to extend the useful life of this unit When service is needed contact a VIONET Authorized Service Agency or your dealer To avoid confus...

Reviews: