2- generale wornings 

 

o

 

please read the operator manual before starting the use of TB10 and follow 
the informations. 

o

 

Maintenance must be operated  ALWAYS with the instrument not connected 
to power supply 

TB5 AND TB10LT are powered by an external  12 VAC. In no any case external power 
supply must be opened or dissasembled.  
TB10MKII is power with 230 VAC cable. It is equipped with power switch and fuses 
protection.  In no any case the power plug and switch must be disassembled. 
Vinteck declines all responsibility for damages to persons, animals and things caused 
by the non-observance of such a provision

 Warning 

- Use of the machine by not properly trained staff. 
- Improper use of the machine. 
- Electric energy defects 
- Repairing and changes made without authorisation. 
- Use of not original or not specific for the model parts. 
- Partial or total non-observance of the instructions. 
- Use of the machine against national specific laws. 
- Calamity and unusual events. 

 
Remaining risk 

Definition of remaining risk: “A danger not completely reducible from the designing and the 
safety devices, i.e. potential and not evident danger”.  
Since the productive aiming, the mechanical qualities and the presupposed proper usage we 
didn’t find any remaining risks, both during the design and the tests. 
Anyway, we recommend: 
- to let only trained staff using the machine;

 

- to check that the machine is supplied by an grounded single-phase electrical cable and  the 
plug has an effective earth terminal. 

 

 

3- instructions manual  
 

3.1 This manual is addressed to following subjects: 
-  Owner; 
-  Operators. 
-  Technical builder 
 

3.2 

Aiming of details in I.M. 

The manual contains a clear description of all technical specifications of the machine aimed 
at the transport, adjusting, maintenance, caution, location of remaining risks. 
 
 
3.3 

Using limits of I.M. 

This manual can never replace an adequate experience of an operator and so it can only be 
a memorandum of the main operations. We specify, moreover. That I.M. mirrors the technical 
data at the moment of the purchase of the machine and that the manufacturer has the right to 
bring up-to-date I.M. and machines without conform I.M. and previous models. 
 
3.4 

How to keep this I.M. 

Summary of Contents for TB10 LT-TB5

Page 1: ...so Vittorio Emanuele II 123 Laboratorio 10141 Torino via Limone 22 Tel 39 339 7626891 fax 39 011 547712 RAEE Nr IT08020000002500 web http www vinteck com e mail info vinteck com TB10 MKII TB10 LT TB5 True bypass MIDI switching Pedalboard User manual Ed 02 rev 2 ...

Page 2: ..._______________ 1 instrument marking TB10MKII TB10LT and TB5 got in back side a little tape non removable with serial and years of building It is very important to report this information in case of need of technical supply Thank you very much for purchase of TB10MKII LT or TB5 pedalboard We really hope that it will be good friend for several ours of music We ask you to write us by email at suppor...

Page 3: ...events Remaining risk Definition of remaining risk A danger not completely reducible from the designing and the safety devices i e potential and not evident danger Since the productive aiming the mechanical qualities and the presupposed proper usage we didn t find any remaining risks both during the design and the tests Anyway we recommend to let only trained staff using the machine to check that ...

Page 4: ...lly single filtered Allow to manage the non midi amps channel change in the same time Allow to manage MIDI multieffects in the same time By driver by an external midi device as a sequencer in ex TB10MKII TB10LT TECHNICAL FEATURES 10 loop True bypass send return made by silver gold plated contact relays 4 switch per p es for amps channel change chained to pulsants 1 4 Extra Send return loop betwwen...

Page 5: ...op with IN true bypass OUT buffer Direct OUT dicet connection with amps A B OUT programmable 5buttons for direct activation of loops with status leds 5 programm change butons 1 5 6 10 Drive the combination of loops and MIDI Program Change With status led 2 buttons UP DOWN MIDI banks 1 5 6 10 11 15 16 20 21 25 etc For channel midi change end switch function selection Display interface three digits ...

Page 6: ...tomp box EXT LOOP Serial loop To be used for always on stomp box es reverb or to connect the amps serial loopand use loop 10 for premaplified signal SND Out signal RTN IN back signal OUT A Out signal to amp or to return in case EXTLOOP with amp send return OUT B Second amp out Or tuner out To be programmed MIDI IN MIDI in signal form external pedalboard or sequencer MIDI OUT MIDI send SWITCH 1 4 N...

Page 7: ...d led indicate status Button 6 Activation of loop 6 Red led indicate status Button 7 Activation of loop 7 Red led indicate status Button 8 Activation of loop 8 Red led indicate status Button 9 Activation of loop 9 Red led indicate status Button 10 Activation of loop 10 Red led indicate status Button P1 6 Activation programming of program change 1 6 11 15 etc Button P2 7 Activation programming of p...

Page 8: ... connectend to 220 plug Vinteck sas do not have any responsibility in case of damage to people animals or objects in caseof non respectof this point No worranty will be applied if power supply unit is disassembled or modified Never disassembly the power switch of TB10MKII No worranty will be applied ifswitch power supply group is disassembled or modified TB10 allow several way to connect to system...

Page 9: ...T No factory preset are programmed DIRECT ACTIVATION OF LOOPS Each loop is activeted by his corrisponded button When a button is pressed the loop is activated When pressed again the loopi is deactivated PROGRAMMING LOOPS COMBINATION To program a combination of loops and switches corresponding to a MIDI program change choose with UP or DOWN the desired bank ex 1 5 or 10 15 Then press the program bu...

Page 10: ... following the selection made by switch Options are S1L during operative function red led will be on Button active loop only S1S during operative function Green led on Button active switch only S1G during operative function Green and red leds on Button active loop and switch together S1t during operative function Both leds off Button does not active loop and switch works in one shot function A ver...

Page 11: ...d on a channel not setted on TB10 7 Spare parts Codice descrizione TB10S7 Pulsant TB10BF Buffer integrated circuit TB10MKIIFT MIDI line protection TB10MKIIMICRO Main program processor TB5PWSY Alimentatore esterno TB5 TB10MKIICOM Boards communications micro 8 warranty terms and conditions TB10KMII TB10LT and TB5 are covered of total warranty of 2 two years from purchase Warranty operation will be p...

Page 12: ...clared EN 55103 1 EN 55103 2 and 60062 1998 Manufacturer Vinteck SAS di Guido Michetti C Corso Vittorio Emanuele II 123 10128 Torino ITALY The equipment identified here conforms to the Directive s and Standards specifed above Type of equipment Effects swithcing system Model TB10MKII TB10LT TB5 Data september 2007 Vinteck sas di Guido Michetti C corso Vittorio Emanulele II 123 10128 Torino Italy ...

Reviews: