background image

Vinteck  

TB10MKII – TB5  –True-bypass MIDI pedalboard

                               pag.10

  

 

Edizione 02 rev.1 

 

 

 

DIRECT ACTIVATION OF THE 4 SWITCH 

On factory preset switches are not active for direc access. 
To active the switches it is necessary to programm them or to select the bottom in that way. 

 
ACTIVATION OF A SWITCH  WITHIN A PROGRAM CHANGE 

When in programming mode (dots of display are on) press the buttons of a switch (1, 2,  3 or 4) and keep it 
pressed for 3 seconds. The corrisponding green led will switch on (S1, S2,  S3 or S4) and red led will switch off, 
and loop as well.  
If the loop must be active as well, shortly press button again. 
Then close the programming mode with defined program button (ex 12). 
 

PROGRAMMING OF A/B SWITCH 

When in programming mode (dots of display are on) press the buttons 5 and keep it pressed for 3 seconds, The 
yellow led of OUT designed will be ON. When red led of loop is ON and not necessary press again the button to 
switch it off.  
Press again the same program button and the memorization is completed. 
If any ather buttom is pressed instead of the program used to began the programming sequence the program 
will be not memorized. 

 
S-P (SWITCHS PROGRAMMING

To activate the direct selection of switches with buttons press DOWN for3 seconds. 
Display will show  S1L. 
Now is possible to select the desired switch pressing pressing the button (1, 2, 3 or 4) 
Diplay will show S1L or S2L or S3L or S4L, following the selection made by switch. 
Options are: 

S1L  during operative function red led will be on. Button active loop only. 

S1S during operative function Green led  on. Button active  switch only 

S1G during operative function Green and red leds on. Button active loop and switch together. 

S1t during operative function Both leds off. Button does not active loop and switch works in one-shot 
function. A very short shot on, to be used in example for  tap-time or for stand-by function of instrument 
whom needs this kind of segnal. Time of  one-shot è di 1/10 of second. One shot function is not 
memorizable in program change. 

 

When finished the selection press again  DOWN to exit. 
 
When assign of function is done, thereis possibility to change while programming the loops combination: 

If active function is “led red” the priorityis on loop. 

If active function is “green red” the priorityis on loop swicth 

If active function is both leds on no variations are allowed. 

If active function is both leds off ( one-shot ) itis possibile to assign the loop to aprogram ch’ange, but 
taptime is usable only from button, not from program ch’ange. 

 
 

MIDI CHANNELS SELECTION 

 
Selection of IN channels, out channels and set of start programchange (1-119 or 1-120) may be defined 
pressing for 3 seconds button UP 
The 3 parameter come following the steps of button press. 
The exit of session is at fourth pression of UP button.  
 
IN CHANNELS 

 

Press UP for 3 seconds. 
 
After 3 seconds will appare on display a little  “i” followed by numbers: 
 
0 = all 
1-16 = channel 1 -16  
 
Press DOWN to change in sequence the channel frrm “all” to 1 to 16. 
 

Summary of Contents for TB10 LT-TB5

Page 1: ...so Vittorio Emanuele II 123 Laboratorio 10141 Torino via Limone 22 Tel 39 339 7626891 fax 39 011 547712 RAEE Nr IT08020000002500 web http www vinteck com e mail info vinteck com TB10 MKII TB10 LT TB5 True bypass MIDI switching Pedalboard User manual Ed 02 rev 2 ...

Page 2: ..._______________ 1 instrument marking TB10MKII TB10LT and TB5 got in back side a little tape non removable with serial and years of building It is very important to report this information in case of need of technical supply Thank you very much for purchase of TB10MKII LT or TB5 pedalboard We really hope that it will be good friend for several ours of music We ask you to write us by email at suppor...

Page 3: ...events Remaining risk Definition of remaining risk A danger not completely reducible from the designing and the safety devices i e potential and not evident danger Since the productive aiming the mechanical qualities and the presupposed proper usage we didn t find any remaining risks both during the design and the tests Anyway we recommend to let only trained staff using the machine to check that ...

Page 4: ...lly single filtered Allow to manage the non midi amps channel change in the same time Allow to manage MIDI multieffects in the same time By driver by an external midi device as a sequencer in ex TB10MKII TB10LT TECHNICAL FEATURES 10 loop True bypass send return made by silver gold plated contact relays 4 switch per p es for amps channel change chained to pulsants 1 4 Extra Send return loop betwwen...

Page 5: ...op with IN true bypass OUT buffer Direct OUT dicet connection with amps A B OUT programmable 5buttons for direct activation of loops with status leds 5 programm change butons 1 5 6 10 Drive the combination of loops and MIDI Program Change With status led 2 buttons UP DOWN MIDI banks 1 5 6 10 11 15 16 20 21 25 etc For channel midi change end switch function selection Display interface three digits ...

Page 6: ...tomp box EXT LOOP Serial loop To be used for always on stomp box es reverb or to connect the amps serial loopand use loop 10 for premaplified signal SND Out signal RTN IN back signal OUT A Out signal to amp or to return in case EXTLOOP with amp send return OUT B Second amp out Or tuner out To be programmed MIDI IN MIDI in signal form external pedalboard or sequencer MIDI OUT MIDI send SWITCH 1 4 N...

Page 7: ...d led indicate status Button 6 Activation of loop 6 Red led indicate status Button 7 Activation of loop 7 Red led indicate status Button 8 Activation of loop 8 Red led indicate status Button 9 Activation of loop 9 Red led indicate status Button 10 Activation of loop 10 Red led indicate status Button P1 6 Activation programming of program change 1 6 11 15 etc Button P2 7 Activation programming of p...

Page 8: ... connectend to 220 plug Vinteck sas do not have any responsibility in case of damage to people animals or objects in caseof non respectof this point No worranty will be applied if power supply unit is disassembled or modified Never disassembly the power switch of TB10MKII No worranty will be applied ifswitch power supply group is disassembled or modified TB10 allow several way to connect to system...

Page 9: ...T No factory preset are programmed DIRECT ACTIVATION OF LOOPS Each loop is activeted by his corrisponded button When a button is pressed the loop is activated When pressed again the loopi is deactivated PROGRAMMING LOOPS COMBINATION To program a combination of loops and switches corresponding to a MIDI program change choose with UP or DOWN the desired bank ex 1 5 or 10 15 Then press the program bu...

Page 10: ... following the selection made by switch Options are S1L during operative function red led will be on Button active loop only S1S during operative function Green led on Button active switch only S1G during operative function Green and red leds on Button active loop and switch together S1t during operative function Both leds off Button does not active loop and switch works in one shot function A ver...

Page 11: ...d on a channel not setted on TB10 7 Spare parts Codice descrizione TB10S7 Pulsant TB10BF Buffer integrated circuit TB10MKIIFT MIDI line protection TB10MKIIMICRO Main program processor TB5PWSY Alimentatore esterno TB5 TB10MKIICOM Boards communications micro 8 warranty terms and conditions TB10KMII TB10LT and TB5 are covered of total warranty of 2 two years from purchase Warranty operation will be p...

Page 12: ...clared EN 55103 1 EN 55103 2 and 60062 1998 Manufacturer Vinteck SAS di Guido Michetti C Corso Vittorio Emanuele II 123 10128 Torino ITALY The equipment identified here conforms to the Directive s and Standards specifed above Type of equipment Effects swithcing system Model TB10MKII TB10LT TB5 Data september 2007 Vinteck sas di Guido Michetti C corso Vittorio Emanulele II 123 10128 Torino Italy ...

Reviews: