background image

8

901301 REV D 10/27/14, SLIMLINE HC PG 8 OF 12

FOR A PROPER SEAL 

OF FITTINGS 

INSTALL SUPPLIED 

O'RINGS AS SHOWN 

AND LUBRICATE 

WITH SUPPLIED OIL.

FIGURE 3

ROUTE HEATER HOSES (REFER TO HEATER HOSE ROUTING INSTRUCTIONS, PG. 9).
MAKE ELECTRICAL AND/OR VACUUM CONNECTIONS, ACCORDING TO THE DIAGRAM FURNISHED

ON PG. 10.  
NOTE:  THE RED 12GA. WIRE WITH THE 30 AMP CIRCUIT BREAKER SHOULD BE CONNECTED TO A 12

VOLT POWER SOURCE OF AT LEAST 12GA. WIRE.  CONNECT MOLDED PLUG WITH THE (RED, YELLOW,

ORANGE) WIRES TO THE CORRESPONDING PLUG FROM THE BLOWER MOTOR.  THE SINGLE BLACK WIRE

FROM THE BLOWER MOTOR  MUST BE GROUNDED. THE BLUE CLUTCH WIRE RUNS FROM THE THERMOSTAT 

TO THE COMPRESSOR SAFETY SWITCH AND FROM THE SAFETY SWITCH TO THE COMPRESSOR. 

 

BE CAREFUL TO ENSURE THAT THIS WIRE IS NOT PINCHED OR IN A POSITION TO RUB ON A SHARP

EDGE AS IT GOES THRU THE FIREWALL.   AN OPTIONAL VACUUM RESERVOIR WITH CHECK VALVE 

WILL HELP SYSTEM WORK UNDER A VARIETY OF CONDITIONS.  

(VINTAGE AIR PART #31200-VUS 

VACUUM RESERVOIR).

#6 O-RING

#8 O-RING

#10 O-RING

SUPPLIED OIL

FOR O-RINGS

O-RING,

SLIDE OVER

MALE INSERT

TO SWAGED LIP

FIGURE 3A

O-RING/FITTING INSTRUCTIONS

HOLD

 TO 

RESIST 

TWISTING

LUBRICATE

O-RINGS

#6 LIQUID

HOSE

#10 SUCTION

HOSE

TIGHTEN

#6 HOSE

#10 HOSE

PRESS TAPE

Summary of Contents for 11301-VUX-A

Page 1: ...SLIMLINE HEAT COOL 11301 VUX A 11401 VUX A 901301 REV D 10 27 14 SLIMLINE HC PG 1 OF 12 an ISO 9001 2008 Registered Company OFF LO MED HI ENCO A C HEAT DEF C...

Page 2: ...tents PAGES 1 COVER 2 TABLE OF CONTENTS 3 PACKING LIST 4 INFORMATION PAGE 5 INSTALLATION 6 INSTALLATION CONTINUED 7 HOSE ROUTING 8 O RING FITTING INSTRUCTIONS 9 HEATER HOSE INSTALLATION 10 WIRING DIAG...

Page 3: ...FOR MISSING OR DAMAGED ITEMS EVAPORATOR KIT PACKING LIST EVAPORATOR KIT 11301 VUX A 11401 VUX A No QTY PART No DESCRIPTION 1 2 3 1 1 1 55328 VUE A 55428 VUE A 64143 VUE 63300 VUE NOTE IMAGES MAY NOT...

Page 4: ...HEATER HOSE YOU MUST PURCHASE 8 FEET OF 5 8 DIA HEATER HOSE FROM VINTAGE AIR 31800 VUD OR FROM YOU LOCAL PARTS RETAILER VINTAGE AIR SYSTEMS ARE DESIGNED TO OPERATE WITH R134a REFRIGERANT ONLY USE OF A...

Page 5: ...9 32 HOLE IN DASH LIP DRILL 9 32 HOLE IN DASH LIP 8 x 1 2 SHEET METAL SCREWS POSITION EVAPORATOR WITH BRACKETS UNDER DASH MARK AND DRILL 2 9 32 DIAMETER HOLES UNDER THE LIP OF THE DASH ATTACH THE FRON...

Page 6: ...WITH A GREASE PENCIL DETERMINE THE BEST LOCATION FOR THE DRIER THAT WILL ALLOW ADEQUATE ROOM FOR THE HOSE AND FITTINGS THAT CONNECT THE DRIER TO THE BULKHEAD FITTING MOUNT THE DRIER KEEP THE DRIER CAP...

Page 7: ...ICAL HOSE ROUTING DIAGRAM DIRECTION OF REFRIGERANT FLOW INDICATED BY ARROWS RECEIVER DRIER NOTE FLOW DIRECTION 6 LIQUID LINE SAFETY SWITCH BINARY ENGINE DRIVEN FAN TRINARY ELECTRIC FAN COMPRESSOR COND...

Page 8: ...ROM THE BLOWER MOTOR THE SINGLE BLACK WIRE FROM THE BLOWER MOTOR MUST BE GROUNDED THE BLUE CLUTCH WIRE RUNS FROM THE THERMOSTAT TO THE COMPRESSOR SAFETY SWITCH AND FROM THE SAFETY SWITCH TO THE COMPRE...

Page 9: ...KEEP THE FREEZE PROTECTION AT THE PROPER LEVEL FOR THE CLIMATE IN WHICH THE VEHICLE IS OPERATING FAILURE TO FOLLOW ANTIFREEZE RECOMMENDATIONS WILL CAUSE HEATER CORE TO CORRODE PREMATURLEY AND POSSIBL...

Page 10: ...NITION SOURCE 5 AMP FUSE FAN SPEED SWITCH BLACK GROUND 30 AMP CIRCUIT BREAKER TO BATTERY OR BATTERY TERMINAL ON REGULATOR ALTERNATOR OR STARTER SOLENOID HEATER CONTROL VALVE ENGINE VACUUM TO INTAKE MA...

Page 11: ...O COLD AND THE EVAPORATOR IS ICING UP AND RESTRICTING AIRFLOW ALLOW THE ICE TO MELT AND SET THE THERMOSTAT WARMER COUNTERCLOCKWISE 1 8 OF A TURN EACH ADJUSTMENT UNTIL THE SYMPTOMS DIMINISH 2 SYMPTOM A...

Page 12: ...D QUANTITIES EVAPORATOR KIT PACKING LIST EVAPORATOR KIT 11301 VUX A 11401 VUX A No QTY PART No DESCRIPTION 1 2 3 1 1 1 55328 VUE A 55428 VUE A 64143 VUE 63300 VUE EVAPORATOR SUBCASE H C w STD LOUVERS...