- 15 -
Parts not included:
Liquid line copper tubing
Suction line copper tubing
Insulated ducts
CAUTION
Liquid and suction line locations may differ from that they are
shown below, please check on the units for proper installations.
NOTE
To prepare rough-in, leave minimum 4” clearances for electrical
wiring and refrigeration piping.
Model No.
Evap Unit
W” x D” x H”
Cond Unit
L” x W” x H”
Electrical Rating
Evap Unit / Cond Unit
Min Circuit Ampacity
Weight (lb)
Evap Unit / Cond Unit
WM-2500SSV
WM-25SFCV
11-3/8 x 11-3/16 x
41-1/2
WM-250SCUR
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-5A
20A
45 / 40
WM-2500SSV-
LA
WM-25SFCV
11-3/8 x 11-3/16 x
41-1/2
WM-
250SCUR-LA
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-6A
20A
45 / 40
WM-4500SSV
WM-45SFCV
11-3/8 x 11-3/16 x
47-1/2
WM-450SCUR
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-6A
20A
55 / 60
WM-4500SSV-
LA
WM-45SFCV
11-3/8 x 11-3/16 x
47-1/2
WM-
450SCUR-LA
18 x 14 x 12
115V-60HZ-1A
115V-60HZ-7A
20A
55 / 60
WM-6500SSV
WM-65SFCV
11-3/8 x 11-3/16 x
51-1/2
WM-650SCUR
24 x 18 x 18
115V-60HZ-2A
115V-60HZ-12A
30A
60 / 90
WM-6500SSV-
LA
WM-65SFCV
11-3/8 x 11-3/16 x
51-1/2
WM-
650SCUR-LA
24 x 18 x 18
115V-60HZ-2A
115V-60HZ-13A
30A
60 / 90
Evap Unit
A
B
C
D
WM-25SFCV
41-1/2”
13”
8-13/16”
8-7/16”
WM-45SFCV
47-1/2”
16”
9-5/16”
13-15/16”
WM-65SFCV
51-1/2”
18”
N/A
N/A