- 13 -
c. Not stopping due to air leak, high
ambient temperature or low
temperature setting
d. Defective controller or probe
e. Low ambient temperature
f. Initially working then stopping,
moisture in the system
g. Refrigerant low or leaking
h. Expansion valve blockage
c. Check for seal, door opening,
ambient
temperature
and
temperature setting
d. Check for controller and probe
e. Change defrost settings
f. Call service
g. Call service
h. Call service
15.Water leak
a. Air leak in the wine cellar causing
excessive condensate
b. High humidity causing excessive
condensate
c. Evaporator air flow restriction
d. Drain restricted or unit not level,
and water overflowing
e. Drip tray leak (No overflow but
leak)
a. Check for air leak
b. Use drain line
c. Check supply air flow or air TD
d. Clean the drip tray and drain line
e. Seal the leak using silicone sealant
16.Excessive
condensate in
wine cellar
a. Air leak in the wine cellar causing
excessive condensate
b. High humidity causing excessive
condensate
c. Drain restricted
a. Check for any air leak
b. Use drain line
c. Clean the drip tray and drain line
17.Condensate
inside ducts
a. Drain line restricted
b. Continually running not stopping
c. Too cold supply air
a. Check for drain
b. raise
temperature
setting
or
increase defrost
c. Increase
air
flow
or
raise
temperature setting
18.Condensate
outside ducts
a. Duct not insulated
b. High humidity
c. Too cold supply air
a. Check for insulation
b. Use dehumidifier
c. Increase
air
flow
or
raise
temperature setting
19.Circuit tripping
a. Incorrect fuse or breaker
b. Incorrect wirings
c. Failed components
a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service
20.Noisy
operation
a. Mounting area not firm
b. Loose parts
c. Compressor overloaded due to
high ambient temperatures or
airflow restriction
d. Defective components
a. Add support to improve installation
b. Check
fan
blades,
bearings,
washers, tubing contact and loose
screws.
c. Check for airflow
d. Call service for checking internal
loose, inadequate lubrication and
incorrect wirings
Summary of Contents for WINE-MATE WM-2500SSV
Page 2: ...1 Important Safety Information...
Page 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 25 65SFCV Evaporator Unit...
Page 18: ...17 Fig 5 WM 250 450SCUR Condensing Unit Fig 6 WM 650SCUR Condensing Unit...
Page 29: ...28 Fig 19 WM 6500SSV LA Electrical Wiring Diagram...