VSP 12 Way Batteryless Telephone System

Technical Manual

A100K10873

Figure 3: 

Cabling diagram based on system configuration example

WHEELHOUSE

ENGINE ROOM

EHS-24

EHS-24

EHS-24

EHS-220

VSP-36-PELP

VSP-36-PELP

STEERING GEAR

CAPTAIN’S CABIN

OPEN DECK

CORRIDOR

Ext. no. 1

Ext. no. 2

Ext. no. 4

Ext. no. 6

Ext. no. 5

Ext. no. 3

Ext. no. 2

24 VDC

+

_

CD-4

10 11 12 13 14 15 16

10 11 12 13 14 15 16

10 11 12 13 14 15 16

10 11 12 13 14 15 16

10 11 12 13 14 15 16

+

+

+

_

_

_

VSP-223-L

VSP-223-L

Ext.

Alarm

stop

Ext.

Alarm

stop

Ext.

Alarm

stop

10 11 12 13 14 15 16

Alternative power 

for common 

battery use

VSP-211-L

24 VDC

24 VDC

24 VDC

220 VAC

+

+

+

_

_

_

External Power

External Power

External Power

External Power

VSP-213-L + VSPK

VSP-213-L + VSPK

IRR-24

IRR-220

VSP-122P

CD-16

Ex

t. n

o.

ENGINE CONTROL ROOM

CHIEF ENGINEER CABIN

Summary of Contents for A100K10873

Page 1: ...TECHNICAL MANUAL Amplified Batteryless Telephone System VSP 12 Way A100K10873 ...

Page 2: ...or configuration are also described The following station models version 6 0 are available for the VSP 12 Way system Product Part Number Main Station panel mounted VSP 211 L Main Station panel mounted with relay circuit VSP 223 L Main Station watertight VSP 122 Main Station portable watertight VSP 122P Main Station panel mounted indoor unit VSP 213 L Publication Log Rev Date Author Comments 4 0 20...

Page 3: ...4 Setting Extension Number 10 4 Operation 11 5 Troubleshooting 12 5 1 Conversation Lines 12 5 2 Call Tone 12 6 Specifications 13 6 1 Electrical Specifications 13 6 2 Certificates 13 7 DIP Switch Settings for Extension Numbers 15 8 Station Mounting Dimensions 16 8 1 VSP 122 16 8 2 VSP 122P 17 8 3 VSP 211 L 18 8 4 VSP 213 L 18 8 5 VSP 223 L 19 Figures Figure 1 System Configuration Example 4 Figure 2...

Page 4: ...independent of the vessel s power supply and fulfills the demands for emergency communication between vital locations onboard The VSP system described in this manual is a system comprising up to 12 main stations with selector switches for selective calling between all connected stations The VSP system can also be connected to a 24V DC power supply and work as a Common Battery Telephone System Figu...

Page 5: ... for weelhouse and control room VSP 223 L Main Station panel mounted with relay Alarm stop button Noise compensated microphone LED call indicator Bulkhead mount in on wall back box MBOKS Suitable for control room and noisy areas VSP 122 Main Station watertight Main station in watertight housing Water resistant mil spec handset Bulkhead mount Suitable for bridge wings and open deck areas VSP 122P M...

Page 6: ...f the board with the old inductor When a call is being made the actual line will carry a generated voltage This voltage is fed through the active line via the corresponding diode D11 and D12 to the amplifier A permanent amplifier 24 VDC power can be supplied on the connection block terminal 23 and 24 L L To avoid noise problems the 24 VDC power supply must be connected via a DC DC converter L L No...

Page 7: ...calling tone frequency is 2500 Hz It is not recommended to change the call tone frequency because it is adjusted to the mechanical resonance of the handset The call tone has a fluttering frequency at about 15 Hz because of the crank speed Depending on environmental noise it is possible to choose a high or low level for the call tone by strapping P7 on the station PCB 2 4 2 Stations for Use in Haza...

Page 8: ... latch relay circuit for activating external audible and or visible signal units Additional terminals 17 22 are added for this feature Local 24 VDC for signal unit 17 24 V and 20 0 V Signal unit connection 18 24 V and 19 0 V Alarm stop button 21 and 22 VSP 211 L station The VSP system can also work as a common battery telephone system when an external 24 VDC power supply is connected to the system...

Page 9: ... Ext no 4 Ext no 6 Ext no 5 Ext no 3 Ext no 2 24 VDC _ CD 4 10111213141516 10111213141516 10111213141516 10111213141516 10111213141516 _ _ _ VSP 223 L VSP 223 L Ext Alarm stop Ext Alarm stop Ext Alarm stop 10111213141516 Alternative power for common battery use VSP 211 L 24 VDC 24 VDC 24 VDC 220 VAC _ _ _ External Power External Power External Power External Power VSP 213 L VSPK VSP 213 L VSPK IRR...

Page 10: ...n number 1 Insert jumpers into pins J2 and J3 2 Activate the DIP switch on the PCB corresponding to the selected number by sliding it to the ON position Figure 4 DIP switch setting for extension no 2 For information on all extension number settings see section 7 DIP Switch Settings for Extension Numbers A label strip with numbers 1 to 12 is shipped with each station Fix the label with the relevant...

Page 11: ...wer and without distortion for a guaranteed period of 20 minutes After 20 minutes the conversation period can be extended by turning the crank again By calling a station with a built in relay circuit for operating external signal units the relay is activated for about 20 seconds The signal may be muted earlier than 20 seconds by pressing the ALARM STOP button located at the front of the station Th...

Page 12: ...rder 5 2 Call Tone Extension numbers 11 and 12 do not work No call tone Jumpers on pins J2 and J3 are not inserted Insert jumpers on pins J2 and J3 located on the right side of the DIP switch Station receives calls from two or more lines Several extension numbers are set Verify that the station has the correct extension number set on the DIP switch No call tone in own station Check the P8 P9 conne...

Page 13: ...bust and corrosion resistant construction and conform to the following Product Specifications IEC 533 2nd edition June 1996 EMC of Electrical and Electronic Installation in Ships and of Mobile and Fixed Offshore Units Det Norske Veritas DNV Certification Notes no 2 4 Environment test Specification for Instrumentation and Automation Equipment Optional EMC requirements IEC 945 February 1995 Maritime...

Page 14: ...d until 2012 06 30 Issued by DET NORSKE VERITAS AS DNV Certificate no ELE 436605CS1 Valid until 2011 03 15 Issued by Registro Italiano Navale RINA Certificate no 03 00041 E1 Valid until 2013 04 07 Issued by Lioyd s Register EMEA Certificate no 09 00033 262 Valid until 2014 01 15 Issued by Russian Maritime Register of Shipping ...

Page 15: ...tension No 6 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 7 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 8 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 9 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 10 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 12 OFF ON 9 1 DIP ...

Page 16: ...16 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 Station Mounting Dimensions 8 1 VSP 122 ...

Page 17: ...17 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 2 VSP 122P ...

Page 18: ...18 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 3 VSP 211 L 8 4 VSP 213 L ...

Page 19: ...19 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 5 VSP 223 L ...

Page 20: ... The company s Quality Assurance System is certified to meet the requirements in NS EN ISO 9001 2008 Zenitel Norway AS reserves the right to modify designs and alter specifications without prior notice in pursuance of a policy of continuous improvement 2010 Zenitel Norway AS support vingtor com DOC NO A100K10873 ...

Reviews: