background image

 

 

 

 

16 

IP Desktop Touchscreen Configuration & Operation

 

A100K11664

 

 

 

Passcode 

Passcode: 

Enter an up to 10 digit long numeric passcode to restrict access to the 

cameras via the Camera Select screen on the station.

 

Camera Types 

 

Camera Types 

Baudisch

 and 

AXIS

 are already predefined. 

Name: 

The input fields on the left panel are for the camera names (e.g. 

TCIV

 for 

Turbine Video). The name entered here will be added to the 

Camera Type

 select 

box in the 

Camera Allocation

 section. 

Path:  

The input fields on the right panel are for the path to the MJPG stream of the 

camera in the form of [:<Port>][Path].  
For TCIV-x Turbine Video stations the path is   

:8090/mjpg/video.mjpg

 

Camera Allocation 

Name : 

Enter the name for the allocated camera (optional). This camera name is 

displayed in the text overlay.

 

AlphaCom Node Number : 

Enter the Node Number of the Alphacom Server on 

which the IP Desktop is registered (AlphaCom mode). 

Enter the value ‘0’ for both 

Pulse and SIP mode. 

AlphaCom Directory Number : 

Enter the Directory Number of the IP station with 

the video camera (AlphaCom mode). 

Enter the value ‘0’ for both Pulse and SIP 

mode. 

SIP ID : 

Enter the Directory Number of the intercom unit which the camera is 

associated with. (SIP/Pulse mode)

 

Camera IP : 

Enter the IP address of the station with the video camera. 

Camera Type : 

Select the camera type based on the available camera types from 

the dropdown box (e.g. TCIV, Baudisch, AXIS). 

Camera User : 

Enter the username to access the camera stream (optional). 

Camera Password : 

Enter the password to access the camera stream (optional). 

Passcode Required : 

Check the box to

 

enable or disable passcode authentication 

to access this camera via the Camera Select screen on the station. 

Allocation active? : 

Check the box to

 

enable or disable the camera. 

This must be 

enabled to be able to stream video from the camera.

 

 

  Click 

Submit settings

 to apply the settings 

 

Summary of Contents for 1408001635

Page 1: ...TECHNICAL MANUAL NR XXXXXXXXXXXX IP Desktop Video Station with Touchscreen Display A100K11664 TECHNICAL MANUAL...

Page 2: ...nterface 6 3 2 1 General Workflow 6 3 2 2 Touchscreen Calibration 10 3 2 3 Factory Reset 10 3 3 Video Screen Web Interface 11 3 3 1 Login Procedure 11 3 3 2 User Settings 12 3 3 3 User Interface 12 3...

Page 3: ...ate for Fw 1 10 1 5 17 12 2014 Eb MTBF and response time of display added 1 6 09 05 2016 Pl Update 2 0 22 06 2016 HKL Revised with Turbine Video 1 3 Firmware Versions Date SubstationKit VideoKit Descr...

Page 4: ...0200 It features a large high contrast touchscreen with backlight which allows critical information about connections to be shown clearly The handset allows the user to switch from private to open con...

Page 5: ...nt readability 2 Level screen saver High Low lighted Touchscreen off Video Touchscreen Firmware VideoKit Internal communication with IP desktop station via DIP protocol 1 1 Text display of the origina...

Page 6: ...Video station to the network Connect the LAN port of the IP Desktop Video station to a PoE network switch using a network cable 3 2 Video Touchscreen Interface 3 2 1 General Workflow During startup th...

Page 7: ...e configured correctly the connection will be established automatically during startup This may take some time Yellow indicates that the video screen is connected to the server Green indicates an acti...

Page 8: ...e configured on the AlphaCom server Tap anywhere on the screen and the Option Screen will be displayed for 10 seconds Option Screen On the Option Screen there are four touch icons for executing the fo...

Page 9: ...o require passcode authentication see section 3 3 4 the following passcode entry screen will be displayed Passcode Entry Screen Enable Disable Camera Switching If more than one camera has been allocat...

Page 10: ...3 6 Touch Calibration Screen When the calibration screen is shown tap the displayed cross and another cross will be displayed After tapping the second cross the calibration process will be completed...

Page 11: ...e LAN port of the IP Desktop to the network switch 3 Make sure your PC is set in the same IP address range as the video screen on the station The default IP address range is 169 254 1 xxx Assign your...

Page 12: ...ord for access to the web interface Click User User name Enter a user name Password Enter a password Repeat password Type in the password again Click Send settings Click Submit settings to apply the s...

Page 13: ...A100K11664 IP Desktop Touchscreen Configuration Operation 13...

Page 14: ...Coordinate x Starting position on the x axis for the Background image Coordinate y Starting position on the y axis for the Background image Width Width of the background image Height Height of the ba...

Page 15: ...A100K11664 IP Desktop Touchscreen Configuration Operation 15 3 3 4 Camera Settings Here you can configure the camera settings for up to 80 cameras Click Cameras...

Page 16: ...e Alphacom Server on which the IP Desktop is registered AlphaCom mode Enter the value 0 for both Pulse and SIP mode AlphaCom Directory Number Enter the Directory Number of the IP station with the vide...

Page 17: ...ettings from a DHCP server DHCP with fallback The IP Desktop Video Station automatically obtains its IP settings from a DHCP server If no DHCP server is available the IP Desktop Video Station falls ba...

Page 18: ...tion Operation A100K11664 3 3 6 System Here you can calibrate the touchscreen do a factory reset update the Desktop Video Station with the latest firmware etc Click System Camera Allocation Upload or...

Page 19: ...pdate click the Choose File button 4 Select the firmware file The file has the extension bin e g 20160216PL_v11_FW_v21_StentofonIPDesktopVideo bin 5 Click the Upload button 6 When the upload is done t...

Page 20: ...3 5 IP Desktop Station Configuration For more detailed information on the configuration of the IP Desktop Station see the manual A100K10788 IP Master Stations Installation Configuration 3 5 1 Logging...

Page 21: ...254 1 100 in the address bar 6 Select whether an encoded connection HTTPS or a non encoded connection HTTP is to be used 7 Enter username admin 8 Enter password alphaadmin The Station Information wil...

Page 22: ...s a subscriber in the field Directory Number Enter the directory number of the station If a directory number is not entered the station will register with its MAC address Use SIP Use Pulse Server IP S...

Page 23: ...he environmental and health risks associated with sending electrical goods to landfill Under the WEEE Regulations all new electrical goods should now be marked with the crossed out wheeled bin symbol...

Reviews: