22
RS10
3 . 9 Stop b utton connection:
Normally closed contact, opening the contact causes the gate to stop and suspends the automatic closing
time (when the button is not engaged, the STOP LED should be lit), if not used then jumper between COM and STOP:
3 . 10 C onnecting th e aerial:
The 17 cm rod is supplied pre-wired, to increase the range connect the aerial, as shown in the figure:
4 . D escription of th e L E D S in th e circuit
N ormally closed b utton
Fig. 12
A b b rev iation C olour L E D status
T erminal status
O P E N
Red
Off
APRI input (terminal 16) not engaged
On
APRI input (terminal 16) engaged
A P C H
Red
Off
APCH input (terminal 18) not engaged
On
APCH input (terminal 18) engaged
A P E D
Red
Off
APED input (terminal 19) not engaged
On
APED input (terminal 19) engaged
ST O P
Green
Off
STOP input (terminal 21) engaged
On
STOP input (terminal 21) not engaged, if not used then jumper between COM and STOP terminals
P H O T O
Green
Off
PHOTO input (terminal 22) engaged (photocell beam interrupted)
On
PHOTO input (terminal 22) not engaged, if not used then jumper between COM and PHOTO ter-
minals
ST P A
Green
Off
STPA input (terminal 23) engaged (sensitive edge pressed)
On
STPA input (terminal 23) not engaged, if not used then jumper between COM and PHOTO termi-
nals
F C A P
Green
Off
"FCAP input (terminal 13) engaged. The gate is in the position of:
Opening limit switch if parameter P18 = R (opening to right)
Closing limit switch if parameter P18 = L (opening to left)"
On
FCAP input (terminal 13) not engaged.
F C C H
Green
Off
"FCCH input (terminal 15) engaged. The gate is in the position of:
Closing limit switch if parameter P18 = R (opening to right)
Opening limit switch if parameter P18 = L (opening to left)"
On
FCAP input (terminal 15) not engaged.
D L 1
Red
"Fast blink"
Flashes quickly if one of the inputs is engaged
Fig. 13
EN
COM
ST
OP
17 18 19 20 21 22 23
5