19
RS10
3 . 1 W iring f or pow er line, f lash ing ligh t and electric motor:
3 . 2 W iring f or 2 4 V outputs:
N umb er D escription
F unction
1-2 -3
P ow er supply line
Power line 230 V ac (1 = phase / 2 = ground wire / 3= neutral)
4 -5
O utput f or f lash ing ligh t
Output for flashing light (230 V a.c. max 40 W)
6 -7 -8
O utput f or pow ering th e electric motor
Output powering the motor (6 = common / 7 = opens / 8 = closes) the capacitor is con-
nected in terminal 7 and 8 in parallel with the electric motor
9 -11
Second radio ch annel or ph oto-test
output
Second radio channel or photo-test output (selectable with parameter P08, max. 65 mA)
10-11
G ate mov ement w arning output
Gate movement warning output (selectable with parameter P07, max. 65 mA)
11-12
2 4 V dc output to pow er accessories
24 V dc output to power photocells and accessories (11 = GND / 12 = +24 Vdc max 300
mA)
230 Vac
Fig. 4
Fig. 5
Second radio channel or photo-test output
The control unit can work with or without an encoder. When switching on, the control unit checks for the presence of the encoder on connector CN6. For
operation without an encoder it is necessary to insert the jumper in connector CN6 as shown in the image fig.4 and power up the control unit. With this
configuration, the obstacle detection function and parameter P16 are not active. For operation with an encoder, it is necessary to insert the cable of the
encoder circuit in the connector CN6 and power the control unit.
CN6
Output for viewing gate movement
24Vdc output to power photocells and accessories
EN
M
COM
AP
CH
COM
AP
CH
LAMP
LAMP
N
PE
L
ELA3
-
-
-
+
2CA
N
AUX
+24V
GND