Example

: (Group 1 – indoor station ID = 8)

1)  Set dip switch 4 in ON position to indicate programming.

2)  Set dip switches 1, 2 and 3 on OFF to select GROUP 1.

3)  Press and hold down P1 until the LED illuminates steadily.

4)  Release P1.

5)  Press door lock button on indoor station ID 8 (example ID for the instructions); the LED will begin to flash

6)  Press and hold down P1 again until the LED goes off.

7)  Release P1.

 

The ID is now assigned.

8)  Set dip-switch 4 back onto OFF.

The relay has 8 independent groups for RL1 and RL2. During programming, the ID is assigned automatically to both RL1 and RL2.  The cancellation procedure, however, must be 

preformed separately for RL1 and RL2.

ID cancellation

 

Relay RL1 ID cancellation table
Group

Dip 1

Dip 2

Dip 3

Dip 4

Group 1 Relay 1

OFF

OFF

OFF

OFF

Group 2 Relay 1

ON

OFF

OFF

OFF

Group 3 Relay 1

OFF

ON

OFF

OFF

Group 4 Relay 1

ON

ON

OFF

OFF

Table 2

Relay RL2 ID cancellation table
Group

Dip 1

Dip 2

Dip 3

Dip 4

Group 1 Relay 2

OFF

OFF

ON

OFF

Group 2 Relay 2

ON

OFF

ON

OFF

Group 3 Relay 2

OFF

ON

ON

OFF

Group 4 Relay 2

ON

ON

ON

OFF

Table 3

Example

: cancelling the ID that has just been assigned (Group 1 – Relay 1 and Group 1 – Relay 2)

1)  Set dip switch 4 in OFF position to indicate cancellation.

2)  Select GROUP 1 of RL1 by setting dip switches 1, 2 and 3 in the OFF position.

3)  Press and hold down P1 until the LED lights up.

4)  When the LED goes off, release button P1.

 

RL1 programming has now been reset.

5)  For RL2, select GROUP 1 of RL2 by setting dip switches 1 and 2 in the OFF position and dip switch 3 in the ON position.

6)  Press and hold down P1 until the LED lights up.

7)  When the LED goes off, release button P1.

 

RL2 programming has now also been reset.

8)  Set all the dip-switches back onto OFF.

NOTE

: All programming on 69PH can be cancelled simultaneously using the “RESET DEFAULT DATA” procedure.

NOTE: The ID with 69PH installed over Horizontal Bus can only be assigned with programmer 950C or SaveProg. 

4) ID ATTRIBUTION FOR RELAY OPERATION IF MORE THAN ONE 69PH IS PRESENT IN THE SYSTEM

The default ID of device 69PH is 1

When operating as RELAYS, there may be up to eight 69PH modules in the system, to a total of 16 actuators. In this case the dip switches must be used to assign an ID to each 69PH module. 

The indoor station must have multiple suitably programmed buttons to activate auxiliary relays.

NOTE: 

More than one relay can be programmed with the same ID if simultaneous activations controlled by the same button are required.

NOTE: 

RL1 and RL2 are activated in the DEFAULT configuration by buttons P2 and P3 on the indoor station, corresponding to AUX 1 and AUX 2 of each configured GROUP. 

The ID of the relay module 69PH is manually assigned by setting the "Dip-switch for assigning ID." For the configuration please refer to Figure 1 and Table 4. 

69PH

Operation

Dip 1 Dip 2 Dip 3 Dip 4

1 (ID 1)

RL1=Auxiliary 1 and RL2=Auxiliary 2

OFF OFF OFF OFF

2 (ID 2)

RL1=Auxiliary 3 and RL2=Auxiliary 4

ON

OFF OFF OFF

3 (ID 3)

RL1=Auxiliary 5 and RL2=Auxiliary 6

OFF

ON

OFF OFF

4 (ID 4)

RL1=Auxiliary 7 and RL2=Auxiliary 8

ON

ON

OFF OFF

5 (ID 5)

RL1=Auxiliary 9 and RL2=Auxiliary 10

OFF OFF

ON

OFF

6 (ID 6)

RL1=Auxiliary 11 and RL2=Auxiliary 12

ON

OFF

ON

OFF

7 (ID 7)

RL1=Auxiliary 13 and RL2=Auxiliary 14

OFF

ON

ON

OFF

8 (ID 8)

RL1=Auxiliary 15 and RL2=Auxiliary 16

ON

ON

ON

OFF

Table 4

4

EN

69PH

Summary of Contents for ELVOX 69PH

Page 1: ...69PH Programmable device with 2 relays Installer manual...

Page 2: ...ossible MANUAL programming is to RESET the configurations made resetting the entered data and returning to the default configuration Note The relay module 69PH is marketed with a default configuration...

Page 3: ...eaches the end of the number of programmed cycles default 5 On answering CHIAMATA DA ESTERNO CHIAMATA INTERNA 1s ON 2s OFF 1s ON 4s OFF 1s ON 2s OFF 1s ON 4s OFF Call from outside Call from inside Fig...

Page 4: ...and hold down P1 until the LED lights up 7 When the LED goes off release button P1 RL2 programming has now also been reset 8 Set all the dip switches back onto OFF NOTE All programming on 69PH can be...

Page 5: ...or station that receives the call must be programmed in the GROUP parameter It is possible to have up to 8 different indoor stations 10 BISTABLE RELAY WITH ACTIVATION BY INDOOR STATION BUTTONS The rel...

Page 6: ...hen programming the indoor station The 6120 modules that send the call and the recipient devices are enabled according to the Enabling map By default all devices are enabled 15 Roller shutter mode Ope...

Page 7: ...aragraph 4 ID assignment Operating modes Bistable T1 activation delay time def 1s T2 deactivation delay time def 1s FLAG State Not YES sends status with each switch NO does not send Bistable relay act...

Page 8: ...120 Roller Shutter Mode Call Progress DEFAULT CALL REPEATER ON ENABLING MAP BISTABLE ATTEMPTED CALL TO GROUP ATTEMPTED CALL ON ENABLING MAP MONOSTABLE ON ACCEPTED CALL BISTABLE ON ACCEPTED CALL MONOST...

Page 9: ...configuration In this mode relays RL1 and RL2 can also operate individually 4 CALL ACTIVATED MONOSTABLE RELAY The relay is activated when a call is sent to an indoor station present in the system whi...

Page 10: ...lectronic units auxiliary units and switchboards subject to an operating window where the start and end ID numbers are to be entered From the INTERNAL ENTRANCE PANEL AUXILIARY SWITCHBOARD submenus the...

Page 11: ...nue with the configuration From INSTALLATION press Relay 1 or 2 will appear By pressing only if the relay 69PH is in the Vertical Bus configuration you can the procedure for entering data referred to...

Page 12: ...f Figure 5 is displayed NOTE When the relay is connected to the HORIZONTAL BUS check off the Flag HORIZONTAL BUS as indicated by the arrow Select the icon highlighted by the arrow in Figure 6 the wind...

Page 13: ...ts ENABLE SINGLE DEVICE checked for configuration by checking off the check box to define which devices are enabled or not If the flag is not checked off a starting and an ending ID need to be entered...

Page 14: ...eats calls from 6120 5 Repeats EXTERNAL calls and calls from 6120 6 Repeats INTERCOM calls and calls from 6120 7 Repeats EXTERNAL and INTERCOM calls and calls from 6120 To change operating mode Select...

Page 15: ...tchboard and confirm with OK to access the category to configure In window 1 WIN 1 indicate the ID of the first device confirm with OK specify the ID of the last device of the window of devices to be...

Page 16: ...e Montante Montante Montante B1 1 2 B2 PRI C B A NC B2 B1 1C 1 2 NO ID 1 NC 2C NO OUT IN PRI 4 7 5 8 IN OUT 5 7 4 PRI C B A NC B2 B1 1C 1 2 NO NC 2C NO C B A NC B2 B1 1C 1 2 NO NC 2C NO L 1C NO NC 2C...

Page 17: ...368 1 EN 55032 EN55035 REACH EU Regulation no 1907 2006 Art 33 The product may contain traces of lead The power supply units constitute a SELV source in observance of the requirements set out in Artic...

Page 18: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com 49400649C0_MI_IT 00 2111...

Reviews: