Example
: (Group 1 – indoor station ID = 8)
1) Set dip switch 4 in ON position to indicate programming.
2) Set dip switches 1, 2 and 3 on OFF to select GROUP 1.
3) Press and hold down P1 until the LED illuminates steadily.
4) Release P1.
5) Press door lock button on indoor station ID 8 (example ID for the instructions); the LED will begin to flash
6) Press and hold down P1 again until the LED goes off.
7) Release P1.
The ID is now assigned.
8) Set dip-switch 4 back onto OFF.
The relay has 8 independent groups for RL1 and RL2. During programming, the ID is assigned automatically to both RL1 and RL2. The cancellation procedure, however, must be
preformed separately for RL1 and RL2.
ID cancellation
Relay RL1 ID cancellation table
Group
Dip 1
Dip 2
Dip 3
Dip 4
Group 1 Relay 1
OFF
OFF
OFF
OFF
Group 2 Relay 1
ON
OFF
OFF
OFF
Group 3 Relay 1
OFF
ON
OFF
OFF
Group 4 Relay 1
ON
ON
OFF
OFF
Table 2
Relay RL2 ID cancellation table
Group
Dip 1
Dip 2
Dip 3
Dip 4
Group 1 Relay 2
OFF
OFF
ON
OFF
Group 2 Relay 2
ON
OFF
ON
OFF
Group 3 Relay 2
OFF
ON
ON
OFF
Group 4 Relay 2
ON
ON
ON
OFF
Table 3
Example
: cancelling the ID that has just been assigned (Group 1 – Relay 1 and Group 1 – Relay 2)
1) Set dip switch 4 in OFF position to indicate cancellation.
2) Select GROUP 1 of RL1 by setting dip switches 1, 2 and 3 in the OFF position.
3) Press and hold down P1 until the LED lights up.
4) When the LED goes off, release button P1.
RL1 programming has now been reset.
5) For RL2, select GROUP 1 of RL2 by setting dip switches 1 and 2 in the OFF position and dip switch 3 in the ON position.
6) Press and hold down P1 until the LED lights up.
7) When the LED goes off, release button P1.
RL2 programming has now also been reset.
8) Set all the dip-switches back onto OFF.
NOTE
: All programming on 69PH can be cancelled simultaneously using the “RESET DEFAULT DATA” procedure.
NOTE: The ID with 69PH installed over Horizontal Bus can only be assigned with programmer 950C or SaveProg.
4) ID ATTRIBUTION FOR RELAY OPERATION IF MORE THAN ONE 69PH IS PRESENT IN THE SYSTEM
The default ID of device 69PH is 1
When operating as RELAYS, there may be up to eight 69PH modules in the system, to a total of 16 actuators. In this case the dip switches must be used to assign an ID to each 69PH module.
The indoor station must have multiple suitably programmed buttons to activate auxiliary relays.
NOTE:
More than one relay can be programmed with the same ID if simultaneous activations controlled by the same button are required.
NOTE:
RL1 and RL2 are activated in the DEFAULT configuration by buttons P2 and P3 on the indoor station, corresponding to AUX 1 and AUX 2 of each configured GROUP.
The ID of the relay module 69PH is manually assigned by setting the "Dip-switch for assigning ID." For the configuration please refer to Figure 1 and Table 4.
69PH
Operation
Dip 1 Dip 2 Dip 3 Dip 4
1 (ID 1)
RL1=Auxiliary 1 and RL2=Auxiliary 2
OFF OFF OFF OFF
2 (ID 2)
RL1=Auxiliary 3 and RL2=Auxiliary 4
ON
OFF OFF OFF
3 (ID 3)
RL1=Auxiliary 5 and RL2=Auxiliary 6
OFF
ON
OFF OFF
4 (ID 4)
RL1=Auxiliary 7 and RL2=Auxiliary 8
ON
ON
OFF OFF
5 (ID 5)
RL1=Auxiliary 9 and RL2=Auxiliary 10
OFF OFF
ON
OFF
6 (ID 6)
RL1=Auxiliary 11 and RL2=Auxiliary 12
ON
OFF
ON
OFF
7 (ID 7)
RL1=Auxiliary 13 and RL2=Auxiliary 14
OFF
ON
ON
OFF
8 (ID 8)
RL1=Auxiliary 15 and RL2=Auxiliary 16
ON
ON
ON
OFF
Table 4
4
EN
69PH