figura - figure 4
Programming with 950C
Connect the 950C programmer to the programming connector (see Fig.1) and wait for a few seconds until the following message appears on the display:
“Select Function: Program Config”.
- Press the
button. The message on the display becomes:
”Select Function: Terminal Mode”
- Press the
button, a text appears indicating the set message language (Italian by default). To select the language, press
for Italian or
for English.
Press the
button. The following message appears:
“Installation”.
With
you enter the Installation menu and you can view the configuration. To keep the current position press
. To change the configuration, press the
button. In this way it varies
from one bus type to another. If the configuration is changed (e.g. from Vert you to change to Horiz) via
, and confirm with
. If the ID number is the one you want, press
, otherwise
enter the number and confirm with
, the DONE confirmation message will be displayed.
NOTE: If 0 is entered, the "New ID DipSw" message will be displayed, confirm with
,
the DONE confirmation message will be displayed.
Confirm with
, you are prompted for the ID number to assign to 69PH. You can confirm the identification number displayed with
or modify it by entering the number on the programmer
keypad and confirm with
. Press
to return to the position in the INSTALLATION menu to continue with the configuration.
From INSTALLATION press
Relay 1 or 2 will appear.
By pressing
, only if the relay 69PH is in the Vertical Bus configuration, you can the procedure for entering data referred to the IDs for the appliances to be enabled if internal, panels (elec-
tronic units), auxiliary units or switchboards. On ENABLING MAP TYPE with button
you can choose between SINGLE or WINDOW ID. Depending on this configuration, on ENABLING
MAP (see programming diagram) you can enter the identifiers by identification number or a window of operation indicating the starting ID and the end ID. For example, by entering 10 and 30, the
enabled identifiers will be IDs from 10 to 30.
To continue with the configuration, press the
button to return to RELAY 1 or 2.
Enter 1 or 2 to choose whether to configure relay 1 or 2 and confirm with
, you can continue with the configuration of the GROUP, REPEATER CALL TYPE, OPERATING MODES, etc. To
configure one of the menu items (e.g. operating modes), press
and scroll through the submenu with the
button. To confirm the function, confirm with
. Upon confirmation DONE
is displayed. To exit the submenu, press the
button.
950C programmer keypad:
- Button:
to confirm (upon confirmation the message displayed reads “Done!”)
- Button:
returns up a level or cancels typing
- Button:
to quit programming
- Arrows button
: to navigate from one menu to another and through the submenus.
- Numbers button
,
: used to indicate the number
of the Group and the ID, to select the language and to activate the flags.
NOTE: ON/OFF is not active.
11
EN
69PH