26 - ENGLISH
8. MAIN CHARACTERISTICS.
• Supply voltage: 120-230V~ 50-60Hz.
• Output: relay with 6(2) A 250 V~ clean change-over contact.
• Max input: 1 VA.
• Adjustment type: ON/OFF.
• Displayed temperature update: every 30 s.
• Room temperature display: 0 °C +40 °C.
• Reading accuracy:
- ≤ ±0,5 °C b15 °C and +30 °C;
- ≤ ±0,8 °C at the extremes.
• Adjustment range:
- +0 °C - +15 °C on antifreeze;
- +5 °C - +35 °C on heating or air conditioning .
• Temperature differential: adjustable from 0.1 °C to 1 °C.
• Reading resolution: 0.1 °C.
• Settings resolution: 0.1 °C.
• Main functions:
- selection from 3 temperature levels: comfort, reduced, anti-
freeze;
- possibility of selecting timed reduced temperature;
- possibility of turning off or turning off with timer;
- remote control of the heating/air-conditioning function;
- remote control of the reduction function;
- display in degrees Celsius or Fahrenheit;
- saving all the settings;
- possibility of entering password with 3-digit PIN to block access
to the configuration menu .
• Protection rating: IP40.
• Appliances of class II:
.
• Nominal pulse voltage: 4000V.
• Number of manual cycles: 3,000.
• Number of automatic cycles: 100,000.
• Type of contact opening: micro-disconnection.
• Type of action: 1B.
• Tracking index: PTI175.
• Pollution rating: 2 (normal).
• Ambient temperature during transport: -25 °C +60 °C.
• Operating temperature: T40 (0 °C +40 °C).
• Software class: A.