36
9.13 Info about the device
This menu lets you view information related to the thermostat and reset the device.
Via
and
you can select:
•
: displays the software version of the device.
• : displays the number of hours that the timer-thermostat relay has been on (the same as the number
of hours of operation of the system).
The counter can be reset, for example at changes in season to differentiate between heating and
air-conditioning, by pressing and holding the
icon.
•
FWuP
: enables starting the procedure for updating the device software. This service requires a Vimar
cloud connection.
- Tap
to learn about the latest software version available for your device; if your device can be
upgraded the
icon will be blinking alongside the new SW version.
- Tap
to start the update from the Vimar cloud and wait until the next time the timer-thermostat
is restarted.
Caution: While updating the SW do not turn off the device, nor access the timer-thermostat with
the By-clima app.
9.14 Lock/unlock PIN setting
This menu lets you add/change the password to inhibit use of the timer-thermostat.
Using
and
set the three digits of the PIN one at a time and then confirm each set digit
with
.
If you wish to have free access to the thermostat (so without it prompting you for a password) it is suf-
ficient to set the PIN to “
000
”.
If you forget the value you entered, proceed as follows to reset the PIN:
1. Cut off power to the timer-thermostat and then restore it again.
2. Within the first 30 s, i.e. before going into Standby mode, go to the PIN menu and enter the new value.
10. Parameters table
Function
Parameters
Value range
Reso-
lution
Default value
Temperature control mode
Selection
TempCtrl
[Heat., Air-con.]
-
Heating
Control algorithm
Algorithm
[ON/OFF, PID]
-
ON/OFF
Hysteresis (ON/OFF)
δ
T
(Differential)
[0.1,..,1]°C
0.1°C
0.2°C
Proportional band (PID)
Band
[0.5,..,5]°C
0.1°C
1°C
Adjustment period (PID)
Period
[10,..,30] minutes
1 min
20 min
External temperature probe
External probe mode
[Off, View,
Temperature Con-
trol, Limitation]
-
OFF