background image

NT00000584-PILOT-PARC-ESCLAVE-AN-200723

INSTRUCTION MANUAL
INSTALLATION |  WIRING |  COMMISSIONING |  MAINTENANCE |

AFNOR CERTIFICATION

ISO 14001

Environnement

AFNOR CERTIFICATION

I S O   9 0 0 1

Q u a l i t é

PILOT PARC SLAVE UNIT

Unit for indoor parking facilities for use with a PILOT PARC 

MASTER

Summary of Contents for PILOT PARC E 1 BI

Page 1: ...INSTRUCTION MANUAL INSTALLATION WIRING COMMISSIONING MAINTENANCE AFNOR CERTIFICATION ISO 14001 Environnement AFNOR CERTIFICATION ISO 9001 Q u a l i t PILOT PARC SLAVE UNIT Unit for indoor parking faci...

Page 2: ...before connecting 5 3 2 Selection of cables and their protection according to NF C 15 100 6 3 3 Maximum connection capacity and tightening torque 6 3 4 Cable gland 7 3 5 Wiring diagrams see 7 ANNEXES...

Page 3: ...ularly check the labels and markings on the product These are required to be replaced if they become illegible Once installation is complete ensure this manual is available to the final user for any l...

Page 4: ...ations established at the time of delivery If the equipment is received without express reservation the purchaser has no recourse against VIM The product must be stored protected from weather shocks a...

Page 5: ...B C Ratings 9 to 80A Polycarbonate Colour RAL7035 IP55 Use 20 C to 40 C 30 to 95 without condensation Conform IEC 695 2 1 test to 960 C Built in switch disconnector 3 points padlockable in OFF positi...

Page 6: ...ing A Type Rating A 2 6 aM 10x38 4 ABB MO325 4 3 5 6 4 5 5 10 6 3 11 5 16 12 5 18 5 25 25 25 32 ABB MO450 32 32 aM 22x58 40 50 63 65 100 80 125 95 125 115 aM 22x58 125 150 aM T0 160 185 aM T0 200 225...

Page 7: ...63 1 ISO M63 2 185 ISO M63 1 ISO M63 2 225 ISO M63 1 ISO M63 2 3 5 Wiring diagrams see 7 ANNEXES page 8 4 COMMISSIONING Product operation refer to the instructions of PILOT PARC MASTER 5 MAINTENANCE A...

Page 8: ...pv1 Rtgv1 A1 A1 A1 22 21 21 22 13 14 PE PE L3 L2 L1 ISOLATOR SWITCH INTZ 1L1 3L2 5L3 2T1 4T2 6T3 1L1 3L2 5L3 1L1 3L2 5L3 1L1 3L2 5L3 2T1 4T2 6T3 2T1 4T2 6T3 2T1 4T2 6T3 M 3 7 1 2 Version with 1 motor...

Page 9: ...ARC MASTER 1 MOTOR TERMINAL N PILOT PARC SLAVE N 3 TERMINAL N PILOT PARC SLAVE N 2 TERMINAL N 1 2 54 53 5 6 6 5 6 5 1 KMgv1 KMgv1 KMgv1 KMpv1 KMpv1 KMpv1 4 3 4 2 1 4 2 1 3 13 14 6 PILOT PARC MASTER 1...

Page 10: ...ER 2 MOTORS TERMINAL N PILOT PARC SLAVE N 3 TERMINAL N PILOT PARC SLAVE N 2 TERMINAL N 64 64 64 64 63 63 63 63 74 74 74 74 73 73 73 73 24V 54 54 54 54 53 53 53 53 1 2 3 1 1 1 1 1 2 2 2 2 2 3 AUXILIARY...

Page 11: ...E N 6 TERMINAL N onto terminal 24V 13 13 14 14 6 Auxiliary contact isolator switch INTZ Auxiliary contact isolator switch INTZ Auxiliary contact isolator switch INTZ Auxiliary contact isolator switch...

Page 12: ...continuously improving equipment the manufacturer reserves the right to make any technical modifications without giving prior notice VIM Les pr s de M gy Sud SOUDAN CS 60120 79401 ST MAIXENT L ECOLE C...

Reviews: