background image

10

Limited Parts Warranty

 – Villara Corporation warrants this product to be free from defects. If a defect is found within 5 years from the 

date of original installation of the product (whether or not actual use begins on that date) Villara Corporation will provide a new or remanu-

factured part, at the Company’s sole option, to replace any defective part, without charge for the part itself. Other costs incurred for diagnos-

ing, repairing, removing, installing, shipping, servicing or handling of defective parts, replacement parts, or new unit is not covered. 

Compressor Warranty

 – Villara Corporation warrants the Compressor to be free from defects. If a defect is found within 10 years from 

the date of original installation of the product (whether or not actual use begins on that date) Villara Corporation will provide a new 

or remanufactured compressor, at the Company’s sole option, without charge for the part itself. Other costs incurred for diagnosing, 

repairing, removing, installing, shipping, servicing or handling of defective compressor, or new unit is not covered.  
This warranty extends only to the original consumer purchaser and is non-transferable. For this warranty to apply, the product must be 

installed according to AquaChill recommendations and specifications, and in accordance with all local, state, and national codes; and 

the product must not be removed from its place of original installation. 

Warranty Conditions: 

1.  Warranties apply only to products in their original installation location.

2.  Installation, use, care, and maintenance must be normal and in accordance with instructions contained in the Owner’s Manual and 

the service information. 

3.  Defective parts must be returned to the distributor through a registered servicing dealer for credit.

LIMITATION OF WARRANTIES

 – ALL IMPLIED WARRANTIES AND OR CONDITIONS (INCLUDING IMPLIED WARRANTIES 

OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) ARE HEREBY LIMITED IN DURA-

TION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY OR CONDITION IS GIVEN AND APPLIES. Some states or prov-

inces do not allow limitations on how long an implied warranty or condition last, so the above may not apply to you. The expressed warran-

ties made in this warranty are exclusive and may not be altered, enlarged, or changed by any distributor, dealer, or other person, whatsoever

Villara Corporation will not be responsible for:

1.  Damage or repair required as a consequence of faulty installation or application by others. 

2.  Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption of 

electrical service. 

3.  Damage or repair needed as a consequence of any misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 

4.  Damage as a result of flood, wind, fire, lighting, freezing, or other conditions beyond the control of Villara Corp.

5.  Damages resulting from operation with inadequate supply of air or water. 

6.  Change in the appearance of the unit that does not affect its performance. 

7.  Parts not supplied or designated by Villara Corporation. 

8.  Villara Corporation product installed outside the U.S.A.

9.  Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever.

10.  Any special, indirect, or consequential property or commercial damage of any nature whatsoever.

Components considered consumables and not covered under warranty are:

Anode

EvapTreat

Components covered under warranty are: 

 

*Case is warrantable for cracks in casing. Claims for damage from brazing, fading, or warping will not be considered for warranty.  

**Propeller is covered under warranty for damage caused by the condenser fan motor.   

***Compressor wiring harness is covered in cases where damage is caused by compressor failure.

Some states do not allow the exclusion of incidental or consequential damage, so the above limitation may not apply to you.

Villara Building Systems / 4700 Lang Ave. , McClellan,  Ca 95652 / 916-646-2700 / www.Aqua-Chill.com

Runs less. Cools more.

LIMITED PARTS AND COMPRESSOR WARRANTY

Model – AQV

Pump Basket

Pump

Condenser Fan Motor

Compressor

Contactor 

Capacitor

Short Cycle Protection Relay

Low Pressure Switch

Sprinkler Assembly

High Pressure Switch

Float Switch

Refill valve

Condenser Coil

*Case

**Propeller

***Compressor Wiring Harness

Summary of Contents for AquaChill AQV

Page 1: ......

Page 2: ...manufactured by villara corporation REV 4 5 18 AQV homeowner s operation manual Now You re Cooler ...

Page 3: ... by 25 40 We are passionate about our customers and assisting in the environmental concerns of today The AquaChill is an important step towards our goal of complete customer satisfaction and doing our part to conserve energy Villara Building Systems is honored and delighted to provide this energy efficient technology to you Please contact us if you have any questions or concerns regarding your new...

Page 4: ......

Page 5: ......

Page 6: ...owner quick tips 7 Electrical wiring diagram 8 System diagram 8 Parts Diagram 9 Warranty information 10 Villara Corporation works continually to improve its products As a result the design and specifications of the AquaChill unit may vary slightly Please contact Villara s Manufacturing Department at 916 646 2700 for specific information on current product design and specifications Statements and o...

Page 7: ... Custom Polyethylene cabinet with UV resistance Sound absorbing construction materials Easy access door for servicing Water Requirements Unit requires a water shut off valve and 1 4 water line Safety Considerations WARNING or DANGER denotes safety alerts regarding hazards that will result in severe injury or death CAUTION denotes alerts to unsafe practices that can result in minor personal injury ...

Page 8: ...or prov inces do not allow limitations on how long an implied warranty or condition last so the above may not apply to you The expressed warran ties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor dealer or other person whatsoever Villara Corporation will not be responsible for 1 Damage or repair required as a consequence of faulty installation or ...

Page 9: ... COIL ASSEMBLY 5 T 8 ROW 8 TOP OF MAIN BODY OF CASING PARTS DESCRIPTION ITEM AQUACHILL PARTS DIAGRAM PARTS BREAKDOWN FRONT VIEW 1 ELECTRICAL CONTROL BOX 2 CONTACTOR 3 TIME DELAY 4 CAPACITOR COMPRESSOR FAN 5 COMPRESSOR SIZE PER MODEL 6 VALVE CARRIER LIQUID LINE 7 VALVE CARRIER SUCTION LINE 8 BALL VALVE FLOAT ASSEMBLY 9 NU CALGON PURGE VAP WATER TREATMENT 10 DRIP DRAIN PURGE ASSEMBLY 11 LOW LEVEL PR...

Page 10: ...ves performance Following is a step by step procedure for normal sump cleaning Regular maintenance and or service is the key to long trouble free performance from your unit The following schedule will help you maintain an efficient unit with good appearance Adhering to the suggested schedule of component replacement at the start of the season will reduce in season maintenance requirements CAUTION ...

Page 11: ...ake sure to turn off the electrical disconnect on the wall before working on the unit When you put your hands in the unit you run the risk of injury if the unit is accidentally turned on from inside the house Never wear slick soled shoes when working on a roof You may slip when you least expect it PERIODIC SERVICE OR MAINTENANCE Service Needs Semi Annual Start up Semi Annual Shut down Rinse off fa...

Page 12: ...AIR WIRING DIAGRAM DANGER of serious injury or death Disconnect all electricity before servicing WARNING There may be multiple disconnects on each unit and all disconnects must be turned off Check local codes for wiring Wiring connections and adjustments should be made ONLY by qualified persons Amperage must not exceed total nameplate ratings of the electrical equipment SYSTEM DIAGRAM Ultra effici...

Page 13: ...e a water valve on the copper water line it is critical that this valve is on during the air conditioning season The base pan has a brass drain plug The drain cap is unscrewed to drain the reservoir during servicing or to drain the reservoir during winter During the summer the drain cap should be in place and tightened properly Preparing your AquaChill for Winter At the end of the cooling season w...

Page 14: ... up connection to non softened water 4 Add EVAPTreat water treatment EVAPTreat product lasts one season 1 Drain flush and clean reservoir Check purge flow operation Refer to unit water treatment bulletin 1 Flush or rinse out base until soap residue is removed TROUBLE SHOOTING Possible Causes 1 Thermostat setting 2 No electrical power 3 Fuse blown 4 Circuit breaker tripped 5 Faulty wiring or shorts...

Page 15: ...15 20minutes forthewatertemperaturetoreach a stable temperature when the unit is operating AQV30X0101 piston size 65 AQV41X0101 piston size 73 WATER TREATMENT Chemical water treatment is usually not required The chlorine and other treatments added to city water are generally more than adequate biocide treatments for residential applications The purge control is provided to reduce the buildup of mi...

Page 16: ...rgevalveadjustmentsshouldbe done slowly as it will take 30secondsfortheinternal water level to adjust to the new setting After several minutes measure the purge rate using the plug elbow as a convenientlocation It is recommended to take several 1 minute measurementsandaveragetheresults Agoodtechniqueistotake3one minutemeasurements over5 10minutesofoperation Ifadjustmentisrequired makesmalladjustme...

Reviews: