CAUTION
Water depth in base will rise over 5” when water flow stops. Check float level setting while the pump is running.
Failure to properly set the float level will cause premature scale buildup, loss in performance, and overflow.
Check float operation by draining water out of the UNIT and then watching the float refill the sump to the proper
level.
Figure 1. Water Connection
Figure 2. Connect supply water line
! WARNING !
Make sure to turn off the electrical disconnect on the wall before working on the unit. When you put your hands in the
unit you run the risk of injury if the unit is accidentally turned on from inside the house.
Never wear slick-soled shoes when working on a roof. You may slip when you least expect it.
PERIODIC SERVICE OR MAINTENANCE
Service Needs
Semi-Annual “Start-up”
Semi-Annual “Shut-down”
Rinse off face of unit louver screen
√
√
Clean water pump screen
√
√
Rinse out base
√
√
Indoor furnace/air handler filter
√
√
3