![Viking VIPR102 Instruction Manual Download Page 6](http://html1.mh-extra.com/html/viking/vipr102/vipr102_instruction-manual_1024215006.webp)
6
Downdraft Ventilators
VIKING RANGE, LLC
PREPARE THE DOWNDRAFT
Exterior Blower Installation
The downdraft is shipped without a blower. Purchase a Model
VEDV900 or VEDV1200 Exterior Blower and mount the
10"
discharge plate
to the downdraft as follows:
1. Place the downdraft on its back on a table of fl at work surface.
2. Remove the
4 nuts
and
2 clamp channels
.
3. Remove
2 screws
and the
gear motor cover
.
4. Carefully position the10" discharge plate under the
bottom
fl ange
of the downdraft.
5. Connect
motor plug
.
6. Replace the gear motor cover and 2 sheet metal screws.
7. Replace the 2 clamp channels and start the 4 nuts, do not
tighten.
8. Slide blower left of right to desired position. Use
cover plate
(supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use
additional screws
(supplied) through bottom fl ange to secure bottom of dis-
charge plate.
NUTS
COVER
PLATE
CLAMP
CHANNELS
SCREWS
GEARMOTOR
COVER
MOTOR
PLUG
10" ROUND
DISCHARGE
PLATE
ADDITIONAL
SCREWS
BOTTOM
FLANGE