Flame Recognition
The re-igniter module features flame sensing circuitry for
each burner. Any active igniter switch applies 120VAC
to the flame sense circuitry and the sense electrode for
the appropriate burner. With a flame present, the module
reads the direct current to ground that passes through
the flame. If a gas valve is engaged, and the re-igniter
does not read enough current (0.2µA) on the selected
burner; the module will begin sparking on all burners
until flame is established. There is a built in sparking
delay of approximately 1 second to allow for low or
waivering flame conditions.
Spark System
The spark ignition system consists of a 4+0 / 6+0
re-igniter module, spark igniters, and an igniter micro
switch harness. Switches are located on the stem of
each gas valve. Turning a surface burner knob past the
OFF postion, closes the igniter micro switch. The closed
circuit signals the reigniter module to begin sparking
on all burners until flame is detected on the burner
presently engaged.
The spark module sends approximately 1 spark per
second to the spark igniters.
Receiving the Appliance
Installer needs to show consumer location of the gas shut-off valve and how to shut it off.
•
Authorized servicer must install the unit in accordance with the Installation Instructions. Adjustments and service
•
should be performed only by an authorized servicer.
Connect unit into a 120V grounded outlet only. If in doubt about grounding of the home electrical system, it is
•
consumer’s responsibility and obligation to have an ungrounded outlet replaced with a properly grounded three-
prong outlet in accordance with the National Electrical Code.
Do not use an extension cord with this appliance.
Insure all packing materials are removed from the unit before operating it to prevent fire or smoke damage
•
should the packing material ignite.
Ensure unit is correctly adjusted by a qualified service technician or installer for the type of gas (Natural or LP).
•
Re-Ignition System
1
2
3
4
5
6
Igniters
Igniter Switch
Igniter / Sense
Electrode
Re-Igniter Module
Gas Valve