background image

99044906B

F20126

D3

BUiLt-in rear DoWnDraFt WarrantY

tHree Year  FULL WarrantY

Built-in downdraft ventilators, all of their component parts and accessories, except as detailed below*, are warranted to be free 
from defective materials or workmanship in normal household use for a period of thirty-six (36) months from the date of original 
retail purchase. Viking Range Corporation, warrantor, agrees to repair or replace, at its option, any part which fails or is found 
to be defective during the warranty period. For the purpose of this warranty, normal household use 

shall not 

include use of this 

downdraft ventilator with a cooking unit that has a grill. The Viking warranty does not cover any additional ventilation products not 
provided by Viking used in conjunction with Viking downdrafts or ventilator kits. This includes, but is not limited to, such devices 
as booster fans or in-line blowers. Any malfunction caused to Viking ventilation products as a direct result of the use of such 
equipment is not covered under the Viking warranty.

Painted and decorative items are warranted to free from defective materials or workmanship for a period of ninety (90) days from 
the date of original retail purchase. ANY DEFECTS MUST BE REPORTED TO THE SELLING DEALER WITHIN NINETY (90) 
DAYS FROM DATE OF ORIGINAL RETAIL PURCHASE.

Five Year  LiMiteD WarrantY

Any ventilator motor which fails due to defective materials or workmanship in normal household use during the second through 
the fifth year from the date of original retail purchase will be repaired or replaced, free of charge for the part itself, with the owner 
paying all other costs, including labor.

This warranty extends to the original purchaser of the product warranted hereunder and to each transferee owner of the product 
during the term of the warranty.

This warranty shall apply to products purchased and located in the United States and Canada. Products must be purchased in 
the country where service is requested. Warranty labor shall be performed by an authorized Viking Range Corporation service 
agency or representative. Warranty shall not apply to damage resulting from abuse, accident, natural disaster, loss of electrical 
power to the product for any reason, alteration, outdoor use, improper installation, improper operation or repair or service to the 
product by anyone other than an authorized Viking Range Corporation service agency or representative. This warranty does not 
apply to commercial usage. Warrantor is not responsible for consequential or incidental damage whether arising out of breach of 
warranty, breach of contract, or otherwise. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential 
damages, so the above limitation or exclusion may not apply to you.

Owner shall be responsible for proper installation, providing normal care and maintenance, providing proof of purchase upon 
request, and making the appliance reasonably accessible for service. If the product or one of its component parts contains a 
defect or malfunction during the warranty period, after a reasonable number of attempts by the warrantor to remedy the defects or 
malfunctions, the owner is entitled to either a refund or replacement of the product or its component part or parts. Replacement of 
a component part includes its free installation. Warrantor’s liability on any claim of any kind, with respect to the goods or services 
covered hereunder, shall in no case exceed the price of the goods or service or part there of which gives rise to the claim.

WarrantY Service: 

Under the terms of this warranty, service must be performed by a factory authorized Viking Range 

Corporation service agent or representative. Service will be provided during normal business hours, and labor performed at 
overtime or premium rates shall not be covered by this warranty. To obtain warranty service, contact the dealer from whom the 
product was purchased, an authorized Viking Range Corporation service agent, or Viking Range Corporation. Provide model and 
serial number and date of original purchase. For the name of your nearest authorized Viking Range Corporation service agency, 
call the dealer from whom the product was purchased or Viking Range Corporation. 

iMportant: 

Retain proof of original 

purchase to establish warranty period.

The return of the Owner Registration Card is not a condition of warranty coverage. You, however, should return the Owner 
Registration Card so that Viking Range Corporation can contact you should any question of safety arise which could affect you.
Any implied warranties of merchantability and fitness applicable to the above described ventilator motor are limited in duration 
to the period of coverage of the applicable express written limited warranties set forth above. Some jurisdictions do not allow 
limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific 
rights, and you may also have other rights which may vary from jurisdiction to jurisdiction.

VIKING RANGE CORPORATION

111 Front Street

Greenwood, Mississippi  38930 USA

(662) 455-1200

Specifications subject to change without notice.

For more product information, call 1-888-VIKING1 (845-4641), or visit the Viking

web site at http://www.vikingrange.com

Summary of Contents for VERSAVENT RVDD330R

Page 1: ...ers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element to reDUce tHe riSk oF inJUrY to perSonS in tHe event oF a range top greaS...

Page 2: ...ety of gas or electric cooktops It can be mounted in island peninsula orconventionalwall locations Thisunitcanbeeasilyinstalled following these basic steps Cut out the countertop opening Mount the unit in the cabinet Install 10 round dis charge plate Install Model VEDV900 or VEDV1200 DIPR151RSS only External Blower Connect the ductwork and electrical Install the cooktop COOK TOP COUNTER TOP CHIMNE...

Page 3: ...t of equivalent duct The chart above shows equivalent feet of elbows and transitions The number of feet of straight duct plus the equivalent feet of transitions and or elbows to be used should equal 40 feet or less note the equivalent feet of various roof and wall caps has been taken into consideration Do not include them in this calculation 3 1 4 X 10 TO 6 RD TRANSITION 3 1 4 X 10 90O ELBOW minim...

Page 4: ...OUT TYP 10 CENTER LINE OF COUNTER CUTOUT CENTER LINE OF DUCT CUTOUT 2 10 10 ROUND DIA CUTOUT TYP 3 6 CENTER LINE OF DUCT CUTOUT can be located within this area CENTER LINE OF COUNTER CUTOUT 19 10 10 ROUND CUTOUT TYP CENTER LINES OF DUCT CUTOUT CENTER LINE OF COUNTER CUTOUT CENTER LINES OF DUCT CUTOUT 241 8 10 x 3 CUTOUT TYP 5 BottoM DiScHarge rigHt SiDe DiScHarge LeFt SiDe DiScHarge BottoM DiScHar...

Page 5: ... allow the unit s power cord to reach iMportant Location oF eLectricaL oUtLet If Model RDIPR101RSS is being installed in a 30 wide cabinet or Model RDIPR161RSS is being installed in a 36 wide cabinet or Model RDIPR151RSS is being installed in a 45 wide cabinet the outlet cannot be located on the back wall of cabinet In these cases the width of the downdraft covers nearly the entire width of the ba...

Page 6: ...of right to desired position Use cover plate supplied to close up any open space 9 Tighten 4 nuts to secure top of blower Use additional screws supplied throughbottomflangetosecurebottomofdischarge plate NUTS COVER PLATE CLAMP CHANNELS SCREWS GEARMOTOR COVER MOTOR PLUG 10 ROUND DISCHARGE PLATE ADDITIONAL SCREWS BOTTOM FLANGE cUt coUntertop opening All Units 1 Measure and cut the countertop opening...

Page 7: ...k connections to make them secure and air tight 3 Connect ductwork to downdraft If necessary LOOSEN nuts and screws that hold remote blower adapter plate in place and slide outlet assembly left or right to meet ductwork Re tighten screws and nuts LEVELING BRACKET FLANGE FACING IN LEVELING BRACKET FLANGE FACING OUT MOUNTING SCREWS MoUnt tHe Unit All Units caUtion BeFore cUtting HoLe in caBinet For ...

Page 8: ...ior blower may not exceed 6 0 amp rating 4 Run 2 wire plus ground power cable from the remote blower to wiring box on 10 round discharge plate 5 Connect downdraft wiring to power cable from remote blower Wire black to black white to white and green to green or bare wire 6 Replace wiring box cover 7 Plug the downdraft s power cord into outlet Make sure that the power cord is routed away from the he...

Page 9: ...ve the paper from the adhesive back of the control line the control up with the three holes and position the control so it is parallel with the front of the counter top Press down firmly for 60 seconds 4 Remove the two nylon thumbnuts from the plastic bag and thread onto the two studs on the control from below the coun ter top Hand tighten only The thumbnuts just need to be snugged by hand They ar...

Page 10: ...10 D3 Downdraft Ventilators viking range corporation This page has been left blank intentionally BACKSIDE OF REMOTE SWITCH TEMPLATE ...

Page 11: ...nism Disconnect power to the cooktop and remove it first Reverse the steps under MOUNT THE UNIT to remove the downdraft from the cabinet All Units operation All Units Up DoWn Raises and lowers vent Turns blower ON when vent is UP and OFF when vent is DOWN DeLaY Allows blower to run for 10 min after button is pressed Delay is activated by holding down any speed control button until the LED indicato...

Page 12: ...er arising out of breach of warranty breach of contract or otherwise Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Owner shall be responsible for proper installation providing normal care and maintenance providing proof of purchase upon request and making the appliance reasonably accessib...

Page 13: ... 2 Toujours mettre en marche la hotte durant la cuisson à feu vif ou la cuisson d aliments à flamber 3 Nettoyer régulièrement les ventilateurs d aération On ne doit tolérer aucune accumulation de graisse sur le ventilateur ou sur le filtre 4 Utiliser une casserole de grosseur appropriée Toujours utiliser une batterie de cuisine proportionnelle à l élément de surface AFIN DE DIMINUER LES RISQUES DE...

Page 14: ...es Installez la surface de cuisson COMPTOIR BOUCHE DE CHEMINÉE CONDUIT ROND DE 25 4 cm 10 po PLAQUE D ÉVACUATION DE 25 4 cm 10 po SpéciFicationS éLectriQUeS 120 VCA 60 Hz 6 0 A max SpéciFicationS éLectriQUeS 120 VCA 60 Hz 4 0 A priSe DeS MeSUreS Tous les appareils 1 Consultez les instructions d installation pour connaître les di mensions de la surface de cuisson du découpage à effectuer dans le co...

Page 15: ... DeS MeSUreS SUite ÉGALE UN CONDUIT DROIT DE 61 CM 2 PI vUe De cÔté De La Hotte avec ventiLateUr intérieUr viDv500 vUe De cÔté De La Hotte avec coUDe ROND DE 25 4 cm 10 po pour connexion au ventilateur extérieur veDv900 ou veDv1200 DIPR150RSS seulement ventiLateUr intérieUr viDv500 74 6 cm 29 5 16 po DU coMptoir aU DeSSoUS DU BoÎtier 5 cm 2 po 45 7 cm 18 po 5 4 cm 2 1 8 po 9 2 cM 3 5 8 po 12 7 cm ...

Page 16: ...du plancher les montants des murs les câbles électriques et les tuyaux de nuisent pas 61 2 cm 24 1 8 po LIGNE DE CENTRE DU DÉCOUPAGE DU COMPTOIR 14 cm 5 1 2 po LIGNES DE CENTRE DU DÉCOU PAGE POUR CONDUIT LIGNES DE CENTRE DU DÉCOU PAGE POUR CONDUIT LIGNE DE CENTRE DU DÉCOUPAGE DU COMPTOIR LIGNE DE CENTRE DU DÉCOUPAGE DU COMPTOIR LIGNES DE CENTRE DU DÉCOU PAGE POUR CONDUIT LIGNES DE CENTRE DU DÉ COU...

Page 17: ... 10 po tournée dans la direction souhaitée 5 Branchez la prise du moteur 6 Replacez le couvercle du moteur et les 2 vis à métal 7 Replacez les 2 profilés et engagez les 4 écrous sans serrer 8 Glissez le ventilateur à gauche ou à droite à la position sou haitée Utilisez la plaque couvercle fournie pour fermer toute ouverture inutile 9 Serrez les 4 écrous four fixer le dessus du ventilateur Utilisez...

Page 18: ...de inférieure pour fixer le bas de la plaque d évacuation VIS PLAQUE COUVERCLE PROFILÉS ÉCROUS PRISE DU MOTEUR COUVERCLE DU MOTEUR VIS SUPPLÉMENT AIRES BRIDE INFÉRIEURE DécoUpage DU coMptoir Tous les modèles 1 Mesurez et découpez l ouverture du comptoir selon la largeur de la surface de cuisson et de la hotte PLAQUE D ÉVACUA TION RONDE DE 25 4 cm 10 po D3 Ventilateurs encastrées Surface de cuisson...

Page 19: ...accordez le conduit à la hotte Au besoin DESSERREZ les écrous et les vis qui maintiennent la plaque d adaptateur du ventilateur et glissez la à gauche ou à droite pour l aligner avec le conduit Resserrez les vis et les écrous BRIDE DE NIVELLE MENT REBORD À L INTÉRIEUR BRIDE DE NIVELLEMENT REBORD À L EXTÉRIEUR VIS DE MONTAGE inStaLLation De L Unité Tous les modèles attention avant De DécoUper L ar ...

Page 20: ... Acheminez un câble à deux brins et à fil de terre entre le ventilateur et la boîte électrique de la plaque d évacuation de 25 4 cm 10 po de diamètre 5 Raccordez les fils de la hotte au câble d alimentation du ven tilateur Raccordez le noir avec le noir le blanc au blanc et le vert au vert ou au fil nu 6 Refermez la boîte électrique 7 Branchez le cordon électrique de la hotte dans la prise Assurez...

Page 21: ...ents et évitez les endroits où un chaudron chaudpourraitêtredéposéoudesliquideschaudsrenversés 4 Sortez les deux écrous en nylon du sachet de plastique et installez les sur les goujons de la télécommande en dessous du comptoir Serrez à la main seulement Les écrous à oreilles doivent être bien appuyés mais seulement à la main et ne servent qu à maintenir la télécommande jusqu à ce que l adhésif soi...

Page 22: ...22 D3 Downdraft Ventilators viking range corporation Cette page a été laissée en blanc volontairement ARRIÈRE DU GABARIT DE LA TÉLÉCOMMANDE D3 Ventilateurs encastrées ...

Page 23: ... L APPAREIL pour enlever la hotte de l armoire Tous les modèles FonctionneMent Tous les modèles HaUt BaS Relèveouabaissele conduit d aération Met le ventila teur en MARCHE lorsque le conduit est RELEVÉ et ARRÊTE le ventilateur lorsque le conduit est ABAISSÉ DéLai Actionne le ventilateur pendant 10 minutes une fois que l on a appuyé sur le bouton Le délai est également activé en appuyant sur un bou...

Page 24: ... d une garantie de la violation d un contrat ou de toute autre cause Certaines juridictions interdisant l exclusion ou la limitation des dommages indirects ou consécutifs il se peut que la limitation ou l exclusion ci dessus ne s applique pas à vous Le propriétaire a la responsabilité d installer et d entretenir correctement le produit de présenter sa facture sur demande et de veiller à ce que l a...

Reviews: