Manual
3/14/2017
PSFEM1xxxxZxxx
Viking Technology
Revision C
Page 24 of 33
www.vikingtechnology.com
5.1.8 Identify Device Data
The table below lists the sector data that will be returned by the SSD upon an
IDENTIFY DEVICE command.
Table 5-2: List of Device Identification
Word
F: Fixed
V: Variable
X: Both
Default Value
Description
0
F
0040h
General configuration bit-significant
information
1
X
See *1
Obsolete
– Number of logical cylinders
(16383)
2
V
C837h
Specific configuration
3
X
0010h
Obsolete
– Number of logical heads (16)
4-5
X
00000000h
Retired
6
X
003Fh
Obsolete
– Number of logical sectors per
logical track (63)
7-8
V
00000000h
Reserved for assignment by the Compact
Flash Association
9
X
0000h
Retired
10-19
F
Varies
Serial number (20 ASCII characters)
20-21
X
0000h
Retired
22
X
0000h
Obsolete
23-26
F
Varies
Firmware revision (8 ASCII characters)
27-46
F
Varies
Model number (xxxxxxxx)
47
F
8010h
7:0- Maximum number of sectors transferred
per interrupt on MULTIPLE commands
48
F
0000h
Reserved
49
F
2F00h
Capabilities
50
F
4000h
Capabilities
51-52
X
000000000h
Obsolete
53
F
0007h
Words 88 and 70:64 valid
54
X
See *1
Obsolete
– Number of logical cylinders
(16383)
55
X
0010h
Obsolete
– Number of logical heads (16)
56
X
003Fh
Obsolete
– Number of logical sectors per track
(63)
57-58
X
See *2
Obsolete
– Current capacity in sectors –
59
F
0110h
Number of sectors transferred per interrupt on
MULTIPLE commands
60-61
F
See *3
Total number of user addressable sectors
62
X
0000h
Obsolete
63
F
0407h
Multi-word DMA modes supported/selected
64
F
0003h
PIO modes supported
65
F
0078h
Minimum Multiword DMA transfer cycle time
per word
66
F
0078h
Manufacturer’s recommended Multiword DMA