15
14
1
1
1
2
3
2
2
Legs are packed in styrofoam top pack.
Note:
Legs should be installed near to where
appliance is to be used, as they are
not secure for long transit.
Note:
It is strongly recommended
that a pallet or lift jack be used rather than tilting.
Raise unit about a foot. Unscrew temporary legs from
couplings.
4
Lower range gently to keep any undue strain from
legs and internal mounting hardware.
3
Screw legs into couplings on all
four corners.
Leg Installation
2
1
1
Remove access door.
Electrical Connection (3-wire)
3
2
1
2
Remove supply cord strain relief
bracket and three supply cord mounting screws
on terminal block.
WARNING
Electrical shock hazard.
To avoid risk or electrical
shock, personal injury or death;
grounding product to the frame
of the unit may or may not be permitted
through your local codes. If ground to the
frame is not permitted then a 4 conductor
power cord must be used.
WARNING
Electrical shock hazard.
To avoid risk of electrical shock,
personal injury or death; verify
your appliance has been
properly grounded in accordance with
local codes or in absence of codes, with
the National Electrical Code (NEC).
ANSI/NFPA 70-latest edition.
3
Feed supply cord up through hole in bottom
of range back.
Note:
If you have a 4-wire connection, see following section for
4-wire connection instructions.
See Electrical Requirements information.
Where local codes do not permit grounding
through neutral, use a 4-wire power supply
cord. The cord or conduit must be secured
to the range with the strain relief bracket.
The electrical connection is made at the
terminal block, which is located behind the
access door on the back of the range.
Summary of Contents for RDSCE2305BSS