Operation
If the
RC-2A
is programmed to answer a ringing line (DIP switch 7 ON), it will answer after the selected ring delay.
A single acknowledgement tone will be heard, signaling the user that the
RC-2A
has answered the line. If a se-
curity access code has been programmed (no code switches set to
D
), a touch-tone "
Q
" plus the security access
code may be entered at this time and a second acknowledgement tone will be heard. After this acknowledgement
tone, the built in 2 digit relay commands can be dialed (see page 5,
C. Relay Activation Codes
). If "
Q
" plus an
incorrect security access code is entered, the
RC-2A
will immediately disconnect (hang-up). To prevent unau-
thorized use, if a user dials "
Q
" plus an incorrect security access code on 5 consecutive incoming calls, the unit
will disconnect and not answer the line for 60 minutes.
If the
RC-2A
is not programmed to answer the line (DIP switch 7 OFF), it can passively monitor a communication
path for the proper access and/or activation code.
The
RC-2A
provides a relay activation (opening or closing a relay contact) remotely via DTMF Touch Tone input
over a standard analog C.O. line or PABX/KSU station. When the correct relay activation code is entered, the
RC-2A
activates its relay contacts on the terminal strip followed by an acknowledgement tone.
A. Legacy Mode
6
1
2
3
1
2
3
4
5
6
7
on
VIKING
©
MODEL RC-2A
REMOTE TOUCH TONE
RELAY CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
RELA
Y
CONT
ACTS
N.O.
COM
N.C.
POWER 12V DC
1
2
3
ENTRY CODE
PROGRAMMING
SWITCHES
EARTH
GND
PWR IN/OUT
12-24V AC/DC
LINE IN
2
3
1
4
5
6
7
8
1
2
3
4
5
6
7
ON
ON
OFF
Switch 1
Switch 2
Switch 3
Switch 4
Relay Activation
Time
OFF
OFF
OFF
OFF
1/2 second
OFF
OFF
OFF
ON
1 second
OFF
OFF
ON
OFF
2 seconds
OFF
OFF
ON
ON
3 seconds
OFF
ON
OFF
OFF
4 seconds
OFF
ON
OFF
ON
5 seconds
OFF
ON
ON
OFF
6 seconds
OFF
ON
ON
ON
7 seconds
ON
OFF
OFF
OFF
8 seconds
ON
OFF
OFF
ON
9 seconds
ON
OFF
ON
OFF
10 seconds
ON
OFF
ON
ON
30 seconds
ON
ON
OFF
OFF
45 seconds
ON
ON
OFF
ON
1 minute
ON
ON
ON
OFF
5 minutes
ON
ON
ON
ON
10 minutes
Note:
DIP switches are shown in factory
default settings.
DIP switches 1-4 provide 16 different relay activation times according to the following table:
C. DIP Switch Settings
Switch
Position
Description
5
OFF
Legacy Programming Mode (factory default)
5
ON
Alternative Programming Mode
6
OFF
Acknowledgement tones OFF
6
ON
Acknowledgement tones ON (factory default)
7
OFF
Auto-answer OFF (factory default)
7
ON
Auto-answer ON
1. Accessing the RC-2A Remotely
Step 1.
Set DIP switch 7 to ON and call the
RC-2A
using a Touch Tone phone.
Step 2.
When the
RC-2A
answers, a single beep (acknowledgement tone) will be heard.
Step 3.
If the security access code has been disabled (one or more code switches set to
D
), go to step 4.
If a security access code has been set (no code switches set to
D
), enter "
Q
" followed by your 3
digit security access code (see page 3,
A. Security Access Code
).
Step 4.
Enter a two digit relay activation code (see page 5,
C. Relay Activation Codes
). A single or dou-
ble beep (acknowledgement tone) should be heard.
Step 5.
Enter "
8
" or "
18
" before hanging up to force the
RC-2A
to release the line. Alternatively, the unit
will disconnect if no Touch Tones are detected for 60 seconds.
Step 6.
Set DIP switch 7 to the desired position.