background image

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

DOD# 228

ZF303200 Rev A

Printed in the U.S.A.

P

P

r

r

o

o

d

d

u

u

c

c

t

t

S

S

u

u

p

p

p

p

o

o

r

r

t

t

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

6

6

6

6

6

6

F

F

a

a

x

x

B

B

a

a

c

c

k

k

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

4

4

3

3

4

4

5

5

T

T

r

r

o

o

u

u

b

b

l

l

e

e

s

s

h

h

o

o

o

o

t

t

i

i

n

n

g

g

W

W

i

i

r

r

i

i

n

n

g

g

1.

When the reader is powered up the LED’s will momentarily light amber,  a victory beep (4-quick beeps) is heard and

then the LED’s will light Red.

2.

Present the correct card and the reader will beep once and LED’s will momentarily turn off. It is up to the control panel

to control dual LED and have the LED turn green when an enrolled card is presented.

If reader does not recognize the card/tag (no beep, no LED flash) or reader has short read range, please see table below
for possible causes and solutions.

Possible Cause

Incorrect wiring

Not enough power

Mounted near electromagnetic interference

Incorrect card used 

Reader/access panel not properly grounded 

Supply generating electromagnetic interference 

Corrective Action

Verify wiring connection

12 VDC suggested

Relocate or provide greater separation from

Verify card compatibility from model number

Quality Earth Ground needed. Verify shield line from the access panel to the
reader is one continuous, connected line.

Linear power supply recommended

If any of the corrective actions mentioned above don’t work, please disconnect the reader from panel and power it with a
separate power supply or 9V battery and test card functionality. By powering it individually and off the installation most vari-
ables that can cause malfunction are eliminated. If after the reader is powered by a separate power source the failure per-
sist, please contact Viking Electronics Product Support.

IMPORTANT:

Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the

telephone line.  It is recommended that a surge protector be installed to protect against such surges.  

!

Connect to Typical Wiegand

Connections on Entry System

(Keep unused leads from shorting)

Connect to “-/Ground” on Entry System/Controller and Earth GND

Note: 

See “Cable Requirements” on page 2.

When using the 

PROX-3

with any Viking Entry System/Controller, the provided 12V DC 500mA power adapter should be used. Follow

the directions below to prepare the power supply.

Step 1. 

Cut off the barrel connector on the powersupply.

Step 2.   

Separate the wires.

Step 3. 

Connect the 12V adapter wires to the power supply wires on 

the 

PROX-3

.

Step 4.  

Plug in the power supply.

(+) Black

(-) Black with

White Stripe

Step 1.

Step 2.

Step 3.

IMPORTANT: 

Do 

NOT

 plug in the

adapter until after 

Step 3

 is completed.

Connect power supply 

wires to the 

PROX-3

 

power supply wires

Summary of Contents for PROX-3

Page 1: ...etallic wall post or single gang electrical box Mounts to Viking VE GNP Series gooseneck pedestal s with optional PROX 3 MK GNP or PROX 3 MK VEGNP mounting kits Designed for outdoor use the PROX 3 comes standard with Enhanced Weather Protection EWP see DOD 859 PROX 3 is designed to meet IP66 Ingress Protection Rating see DOD 859 Pigtail connection for easy installation Four red LED s indicates pow...

Page 2: ...mation regarding the defect such as options set conditions symptoms methods to duplicate problem frequency of failure etc 2 Packing Return equipment in original box or in proper packing so that damage will not occur while in transit Static sensitive equipment such as a circuit board should be in an anti static bag sandwiched between foam and individual ly boxed All equipment should be wrapped to a...

Page 3: ...ortant After mounting and testing the card reader clean the front recessed area of the unit with rubbing alcohol and apply the provided label Please note the label is permanent and not easily removed VIKING MODEL PROX 3 4 6 32 x 1 25 long 5 64 hexdrive flathead screws included with mounting kit Model PROX 3 PROX 3 Label included 1 4 20 Nylock nuts included with mounting kit use with carriage bolts...

Page 4: ...rovide greater separation from Verify card compatibility from model number Quality Earth Ground needed Verify shield line from the access panel to the reader is one continuous connected line Linear power supply recommended If any of the corrective actions mentioned above don t work please disconnect the reader from panel and power it with a separate power supply or 9V battery and test card functio...

Reviews: