VIKING TECHNICAL SUPPORT 1.800.908.0884
3 4
LED References
In addition to the LCD Display, the control board LEDs monitor the various circuits of the
control board. Use the table below to identify the corresponding “TS Ref#” and refer to
page 36-39 for further troubleshooting.
# LED
Status
Meaning
Page 39
TS Ref#(s)
1
“Open”
OFF
Normal Condition.
SOLID
Control board is receiving an input for a device connected to any of the
following input terminals: Exit, Fire, Strike or Open (pages 29, 40).
9, 10
2
“STOP”
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the
Stop terminal (pages 29, 40).
9, 10
3
“Close”
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the
Close terminal (pages 29, 40).
9, 10
4
“C Loop”
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the
C Loop terminal (pages 29, 40).
9, 10
5
“ATG”
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the ATG
terminal (pages 29, 40).
9, 10
6
“Re-Open”
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the Re-
Open terminal (pages 27, 32, 40).
9, 10
7
“UL”
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the UL
terminal (pages 12-13, 40).
9, 10
8
“Radio”
OFF
Normal Condition.
SOLID
Control Board is receiving an input from a device connected to the
Radio terminal (pages 28, 40).
9, 10
TROUBLESHOOTING