Viking FGIM-FPIM_15_Pro_Ice-Machine Installation Manual Download Page 5

9

8

15”W. Undercounter/Freestanding Ice Machine

Description

FGIM515

FPIM515

Overall width

14-7/8” (37.8 cm)

Overall height

33-7/8” (86.0 cm) min. to 34-7/8” (88.6 cm) max.

Overall depth from rear
(without door panel)
(with door panel)
(with door handle)

22” (55.9 cm)

22-3/4” (57.8 cm)
25-1/4” (64.1 cm)

Cutout width

15” (38.1 cm)

Cutout height

34-1/4” (86.4 cm) min. to 35-1/4” (89.5 cm) max.

Cutout depth

24” (61.0 cm)

Electrical requirements

115V/60 Hz, 15 amp dedicated circuit

6’ 3-wire cord attached to product

Maximum amp usage

5.0 amps

Inlet water requirement

1/4” OD copper tubing inlet waterline

20 psi min. to 80 psi max.

40°F (5°C) min. to 100°F (38°C) max.

Drain requirements

5/8”  ID x 7/8” OD plastic tubing

required

3/8” ID x 10’ plastic tubing supplied

Temperature requirements

50°F (10°C) min. to 100° (38°C) max.

Maximum storage capacity

26 lbs.

Approximate 
shipping weight

113 lbs. (51.25 kg)

118 lbs. (53.5 kg)

CUTOUT DIMENSIONS

15” (38.1 cm)

34-1/4” (86.4 cm) min.

to

35-1/4” (89.5 cm) max.

24

(6

1.

cm

)

Summary of Contents for FGIM-FPIM_15_Pro_Ice-Machine

Page 1: ...poration 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com UL C UL Viking Installation Guide 15 W Undercounter Freestanding Ice Machine ...

Page 2: ... DO NOT remove permanently affixed labels warnings or plates from the product This may void the warranty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference A GFI shall be used if required by NFPA 70 Nationa...

Page 3: ...ppliance in a way that minimizes the possibility that children will find it There have been many cases in years past of children crawling inside junked and abandoned refrigeration units and becoming trapped or suffocated Contact your municipal waste disposal authority to find out the best and safest way to dispose of your old refrigeration unit DIMENSIONS PROFESSIONAL 14 3 4 37 5 cm 3 7 8 9 8 cm F...

Page 4: ...5 9 cm 2 1 2 6 4 cm 22 3 4 57 8 cm 20 3 8 51 6 cm 115 0 Door Swing Dimensions FGIM FPIM w Designer door panel 7 6 DIMENSIONS CUSTOM PANEL 19 1 4 48 9 cm 22 3 4 57 8 cm 33 7 8 86 0 cm min to 34 7 8 88 6 cm max 14 7 8 37 8 cm 14 7 8 37 8 cm 14 7 8 37 8 cm 30 5 16 77 0 cm 14 3 4 37 5 cm 3 7 8 9 8 cm Floor drain access hole 90 0 37 3 4 95 9 cm 22 3 4 57 8 cm 20 3 8 51 6 cm 90 0 115 0 Door Swing Dimens...

Page 5: ...4 61 0 cm Electrical requirements 115V 60 Hz 15 amp dedicated circuit 6 3 wire cord attached to product Maximum amp usage 5 0 amps Inlet water requirement 1 4 OD copper tubing inlet waterline 20 psi min to 80 psi max 40 F 5 C min to 100 F 38 C max Drain requirements 5 8 ID x 7 8 OD plastic tubing required 3 8 ID x 10 plastic tubing supplied Temperature requirements 50 F 10 C min to 100 38 C max Ma...

Page 6: ...10 microSiemens cm A reverse osmosis system should include post treatment to satisfy the R O water s potential aggressiveness Deionized water is not recommended Because water softeners exchange one mineral for another softened water may not improve water conditions when used with ice machines Where water is very hard softened water could result in white mushy cubes that stick together If in doubt ...

Page 7: ... to the door using a screw supplied with door panel 6 Insert hole plug over screw installed in step 5 supplied 7 Return the gasket to its original position CUSTOM PANEL A custom panel of wood or other material not exceeding 15 lb can be attached to the door Attachment is from the ice side of the door Holes are provided in the door for this purpose To create and attach a custom panel Panel width 14...

Page 8: ...inets To prevent that insert a stop into the provided hole in the top and bottom hinges Drive the pin into the hole until the head is against the hinge HINGE COVERS After the hinge pins are installed if used and the door panel has been attached attach the hinge covers 1 Slide the hinge cover over each hinge 2 Attach the side cover over the hinge by peeling off the covering over the adhesive and pl...

Page 9: ...el Water Inlet Tube field supplied Drain Hose Barbed Elbow Drain Hose Route to building drain CAUTION Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice Gravity drain tubing must be vented have no kinks and slope to the building drain Air gaps are typically required by local code WATER DRAIN INSTALLATION The recommended water suppl...

Page 10: ...der the warranty KEEP THIS MANUAL FOR FUTURE REFERENCE Model and Serial number ELECTRICAL CONNECTION The ice machine is supplied with a power cord DO NOT remove the grounding pin from the cord s plug DO NOT use extension cords Follow all codes Connect the machine to its own 115 volt 15 amp circuit FINAL INSTALLATION 1 If the electrical outlet for the ice maker is behind the unit plug in the unit 2...