Warnings & Important Safety Instructions ______________________________________________________________________3
Dimensions (Professional) ____________________________________________________________________________________5
Dimensions (Designer) ______________________________________________________________________________________6
Dimensions (Custom Panel) __________________________________________________________________________________7
Specifications ______________________________________________________________________________________________8
Cutout Dimensions _________________________________________________________________________________________9
Drain/Electrical Locations___________________________________________________________________________________10
General Information _______________________________________________________________________________________11
Air Flow __________________________________________________________________________________________________11
Filters and Treatment ______________________________________________________________________________________11
Installation Overview_______________________________________________________________________________________12
Door Panel _______________________________________________________________________________________________12
Custom Panel _____________________________________________________________________________________________12
Door Panel Attachment ____________________________________________________________________________________14
Door Swing Change _______________________________________________________________________________________15
Water and Drain Installation ________________________________________________________________________________16
Electrical Connection ______________________________________________________________________________________18
Final Installation ___________________________________________________________________________________________18
Installation Checklist _______________________________________________________________________________________18
Service Information ________________________________________________________________________________________19

IMPORTANT – PLEASE READ AND FOLLOW

•    Before beginning, please read these instructions completely and carefully.
•  

DO NOT

remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.

•  Please observe all local and national codes and ordinances.
•  Please ensure that this product is properly grounded.
•                     The installer should leave these instructions with the consumer who should retain for local inspector’s use and for

future reference.

A GFI 

shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.

• The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of

water or moisture.

• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which are not installed properly or

do not meet the requirements below.

If the use of a GFI is required

, it should be:

• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible

It is your responsibility to be sure your ice machine is:

• located so the front is not blocked to restrict incoming or discharge air flow.
• properly leveled.
• located in a well ventilated area. 
• connected to the proper kind of outlet, with the correct electric supply and grounding. A 115V, 60 Hz, 15 amp fused

electrical supply is required. 

Note:

Time delay fuse or circuit breaker is recommended.

• not used by anyone unable to operate it properly.
• used only for its intended purpose.
• properly maintained.

•SAVE THESE INSTRUCTIONS•

WARNING

To reduce the risk of fire, electric shock, or injury when using your unit, follow these basic
precautions:

• Read all instructions before using the unit.
• Never allow children to operate, play with, or crawl inside the unit.
• Never clean unit parts with flammable fluids. The fumes can create a fire hazard or explosion.
• Always turn the power on/off switch (located behind the air grille on top right side) to the OFF

position before attempting to change light bulbs, clean, or service the unit.

FOR YOUR SAFETY

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE. THE FUMES CAN CREATE A FIRE HAZARD OR
EXPLOSION.

Summary of Contents for FGIM-FPIM_15_Pro_Ice-Machine

Page 1: ...poration 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com UL C UL Viking Installation Guide 15 W Undercounter Freestanding Ice Machine ...

Page 2: ... DO NOT remove permanently affixed labels warnings or plates from the product This may void the warranty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference A GFI shall be used if required by NFPA 70 Nationa...

Page 3: ...ppliance in a way that minimizes the possibility that children will find it There have been many cases in years past of children crawling inside junked and abandoned refrigeration units and becoming trapped or suffocated Contact your municipal waste disposal authority to find out the best and safest way to dispose of your old refrigeration unit DIMENSIONS PROFESSIONAL 14 3 4 37 5 cm 3 7 8 9 8 cm F...

Page 4: ...5 9 cm 2 1 2 6 4 cm 22 3 4 57 8 cm 20 3 8 51 6 cm 115 0 Door Swing Dimensions FGIM FPIM w Designer door panel 7 6 DIMENSIONS CUSTOM PANEL 19 1 4 48 9 cm 22 3 4 57 8 cm 33 7 8 86 0 cm min to 34 7 8 88 6 cm max 14 7 8 37 8 cm 14 7 8 37 8 cm 14 7 8 37 8 cm 30 5 16 77 0 cm 14 3 4 37 5 cm 3 7 8 9 8 cm Floor drain access hole 90 0 37 3 4 95 9 cm 22 3 4 57 8 cm 20 3 8 51 6 cm 90 0 115 0 Door Swing Dimens...

Page 5: ...4 61 0 cm Electrical requirements 115V 60 Hz 15 amp dedicated circuit 6 3 wire cord attached to product Maximum amp usage 5 0 amps Inlet water requirement 1 4 OD copper tubing inlet waterline 20 psi min to 80 psi max 40 F 5 C min to 100 F 38 C max Drain requirements 5 8 ID x 7 8 OD plastic tubing required 3 8 ID x 10 plastic tubing supplied Temperature requirements 50 F 10 C min to 100 38 C max Ma...

Page 6: ...10 microSiemens cm A reverse osmosis system should include post treatment to satisfy the R O water s potential aggressiveness Deionized water is not recommended Because water softeners exchange one mineral for another softened water may not improve water conditions when used with ice machines Where water is very hard softened water could result in white mushy cubes that stick together If in doubt ...

Page 7: ... to the door using a screw supplied with door panel 6 Insert hole plug over screw installed in step 5 supplied 7 Return the gasket to its original position CUSTOM PANEL A custom panel of wood or other material not exceeding 15 lb can be attached to the door Attachment is from the ice side of the door Holes are provided in the door for this purpose To create and attach a custom panel Panel width 14...

Page 8: ...inets To prevent that insert a stop into the provided hole in the top and bottom hinges Drive the pin into the hole until the head is against the hinge HINGE COVERS After the hinge pins are installed if used and the door panel has been attached attach the hinge covers 1 Slide the hinge cover over each hinge 2 Attach the side cover over the hinge by peeling off the covering over the adhesive and pl...

Page 9: ...el Water Inlet Tube field supplied Drain Hose Barbed Elbow Drain Hose Route to building drain CAUTION Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice Gravity drain tubing must be vented have no kinks and slope to the building drain Air gaps are typically required by local code WATER DRAIN INSTALLATION The recommended water suppl...

Page 10: ...der the warranty KEEP THIS MANUAL FOR FUTURE REFERENCE Model and Serial number ELECTRICAL CONNECTION The ice machine is supplied with a power cord DO NOT remove the grounding pin from the cord s plug DO NOT use extension cords Follow all codes Connect the machine to its own 115 volt 15 amp circuit FINAL INSTALLATION 1 If the electrical outlet for the ice maker is behind the unit plug in the unit 2...

Reviews: