Installation

A.  New Construction Flush Mounting

B.  Old Work / Remodel Flush Mounting (Using an recommended Carlon BH234R             

Rough-In Box)

C.  Surface Mounting

Step 1

Recommended mounting heighy to bottom of the rough-in box is 50” - 54”. Front of box
should stick out approximately ½" from front surface of wall stud (this may vary depending
on the walls sheathing and  siding thickness). 

Caution:

Rough-In box must be mounted

LEVEL

and must 

NOT

stick out beyond the front surface of siding. 

Step 2

To maintain a vapor barrier on outside wall applications, caulk around the box, filling any
gaps between the box and the rough opening. Apply caulk to any holes in the box around
wires, etc.

Step 3

When installing siding cut a hole just large enough for the Rough-In box opening.

Caution:

Too large of a hole can cause plate misalignment and compromise the gasket

seal. 

Note:

A siding mounting block is recommended when mounting to vinyl siding or

siding with a 4 inch or less horizontal lap. Contact siding installer for  the correct mounting
block.

Step 1

Recommended mounting heighy to bottom of the rough-in box is 50” - 54”. Make sure
mounting location is free of wall studs, wires, etc.

.

Step 2

Place Rough-In box 

LEVEL

against siding. Trace outline of box onto siding.  

Note:

A

siding mounting block is recommended when mounting to vinyl siding or siding with a
4 inch or less horizontal lap. Contact siding installer for  the correct mounting block.

Step 3

Cut a hole through the siding and wall sheathing just large enough for the rough-in box.

Caution:

Too large of a hole can cause plate misalignment and compromise the gasket

seal

.

Step 4

The front surface of the Rough-In box can be mounted flush against wood siding or
can be recessed and mounted flush against wall sheathing when mounting on
aluminum, steel or vinyl siding.

Step 5

When mounting to 5/8 inch thick or less wall sheathing the two attached screws with
wing brackets can be used to secure the rough-in box. When mounting to surfaces
thicker than 5/8 inch, four standard flat head dry wall screws can be used to secure the
Rough-In box through its mounting ears. (See page 4 Section    D.)

Step 6

To maintain a vapor barrier on outside wall applications, caulk around the box, filling
any gaps between the box and the rough opening. Apply caulk to any holes in the box
around wires, etc.

The 

E-70

is designed to be flush mounted into a double gang rough-in box with minimum inside

dimensions of 2.25” deep x 3.65” wide x 2.84” tall. The 

E-70

can also be surface mounted in a Viking

model 

VE-5x5

(not included, see 

DOD# 424

).  

WARNING:

Do 

NOT

use a typical “wet location box” as not all styles seal properly with the 

E-70

faceplate.

A Viking model 

VE-5x5

can be used to surface mount an 

E-70

to a wall or post. ecommended

mounting heighy to bottom of the rough-in box is 50” - 54”. Drill a small wire exit hole in wall. Pull
wire through and seal hole around wire with putty or caulking. Route wire into the 

VE-5x5

box,

securely screw it to wall or post and seal hole in box around wire with putty or caulking. 

Note:

Conduit may also be used when surface mounting wire, but should not enter through the top of the

VE-5x5

. When routing wiring from above, a drip loop is required. 

WARNING:

Do 

NOT

use a typical

“wet location box” as not all styles seal properly with the 

E-7   0

faceplate.

3

Summary of Contents for E-70-BK

Page 1: ...unique front and back door chimes and paging when used with a Viking SLP 1 SLP 4 and C 2000B Residential commercial and industrial door security Use with a Viking K 1900 5 or K 1900 30 for automatic s...

Page 2: ...ABLOY company All other trademarks are the property of their respective owners AWID is a trademark of Applied Wireless Identification Group Faceplate Gasket 1 8 thick closed cell PVC to provide a wate...

Page 3: ...an cause plate misalignment and compromise the gasket seal Step 4 The front surface of the Rough In box can be mounted flush against wood siding or can be recessed and mounted flush against wall sheat...

Page 4: ...ad Screws included Old Work Double Gang Rough In Box with minimum dimensions of 3 65 W x 2 84 H x 2 25 D Carlon BH234R box shown not included Optional VE 5x5 Surface Mount Box with Black Satin Powder...

Page 5: ...64 LED3 LED1 LED2 LED4 LED5 LED6 LED7 C C C C C C C J11 1 2 3 J10 1 2 3 J9 1 2 3 J8 1 2 3 J7 1 2 3 1 2 3 on 4 5 VIKING MODEL C 2000B VIKING ELECTRONICS HUDSON WI 54016 ADVANCED DOOR GATE AND ENTRY PHO...

Page 6: ...ial St Hudson WI 54016 P N DEV Complies with FCC Part 15 and 68 Reg No US AH3TE08A22264 Back View of the E 70 Circuit Board Mounting Plate Black GND Red 5 14VDC Green Date 0 White Data 1 Up to 500 ft...

Page 7: ...ection DIP switch 2 OFF With DIP switch 3 in the OFF position the E 70 is in the Normal Operation Mode factory setting By placing DIP switch 3 in the ON position the E 70 s programming mode is enabled...

Page 8: ...H Silence Time Out G Call Length Time Out This feature selects the maximum length of time that calls can be connected Programmable in increments of 1 minute up to a maximum of 9 minutes To disable the...

Page 9: ...RIKE 4 DOORBELL SWITCH AUX INPUT AUX CONTACT OUTPUT PHONE LINE INPUT LINE OUT TO PHONES ANALOG STATION INPUT Entry Phone 1 E 65 SS shown Example Front Door C O Phone Line Input To Standard Analog Touc...

Page 10: ...NE OUT TO PHONES 1 2 3 4 ENTRY PHONE 1 5 6 7 8 9 DOOR STRIKE 1 N C N O COM ENTRY PHONE 2 13 14 SLP CONTROL 18 19 TRIGGER INPUT 1 10 11 12 TRIGGER INPUT 2 15 16 17 DOOR STRIKE 2 N C N O COM 5A 30VDC 25...

Page 11: ...PHONE N O COM N C AUX CONTACTS ON 1 2 3 AUX POWER OUTPUT VIKING POWER 13 8V AC VIKING ELECTRONICS HUDSON WI 54016 SINGLE ENTRY PHONE CONTROLLER MODEL C 200 RING COUNT 1 EARTH GND 1 RELAY MODE 2 DOORB...

Page 12: ...LE OR USE OF THE PRODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY...

Reviews: