The Auto Answer/Loud Ring feature can be set to one of four modes.

0 = Disabled

:  In the “Disabled” mode the phone will not automatically answer an incoming call. 

CAUTION:

In the “Disabled” mode,

touch tone programming will not be possible.

1 = Auto Answer

(factory setting):  In the “Auto Answer” mode the phone will automatically answer an incoming call on the first ring. 

2 = Loud Ring

:  In the “Loud Ring” mode the phone will not automatically answer an incoming call but will output a loud ring signal

out of the speaker in a 2 seconds on, 4 seconds off ring pattern. The call can then be answered by pressing the button.

3 = Loud Ring with AGC

:  In the “Loud Ring with AGC” mode the phone will not automatically answer an incoming call but will output

a loud ring signal out of the speaker in a 2 seconds on, 4 seconds off ring pattern. The phone will automatically increase or decrease
the ring volume based on background ambient noise. The call can then be answered by pressing the button.

20. Auto Answer / Loud Ring (#33)

The “Call” LED can be programmed to one of three different modes: 0/OFF, 1/Entry Phone (factory setting), or 2/Emergency Phone. 

0 = OFF Mode: 

Useful for silent monitoring applications. In this mode the LED will not light during normal operation. It will only light

(blink) if it cannot register with the programmed SIP server or while manually resetting all network parameters to factory default. 

1 = Entry Phone Mode:

The LED will remain ON in the idle state, turn off while button is pressed, blink during dialing, light steady

when the call is answered, then turn OFF momentarily when the call is completed.

2 = Emergency Phone Mode: 

The LED will remain OFF in the idle state, blink during dialing, light steady when the call is connected,

then turn OFF when the call is completed.

3 = Emergency Phone Outbound Only: 

On outbound calls, the LED will remain OFF in the idle state, blink during dialing, light

steady when the call is connected, then turn OFF when the call is completed. On in-bound calls, the LED will remain off. This is
useful for silent monitoring on inbound calls.

19. LED Mode (#32)

The Speaker Mode can be set to one of the following three modes. 

0 = OFF/Silent Monitoring Mode:

In the “OFF” mode the speaker is disabled at all times. However, the speaker can be enabled

after communication has been established by entering touch tone command “

9#

”. The speaker will remain on for the duration of the

call.

1 = ON (factory setting):

In the “ON” mode the speaker is enabled during In-bound and Out-bound calls. 

2 = OFF Until Answered: 

In the “OFF Until Answered” mode the speaker will remain silent during dialing and will not turn on until

the called party has answered. 

18. Speaker Mode (#31)

The call LED on the 

E-60-IP 

phone can be programmed to:

0 =

LED will automatically light when the distant party has answered, this is the factory default setting.

1 =

LED will light steady, only after a Touch Tone 

Q

is entered from the called party.

17. “Call” LED Control (#30)

With “

Q

1” (factory default) programmed the CALL button alternately connects and disconnects calls. With “

Q

2” programmed the

CALL button connects calls only. Pressing the button again after the call has been initiated will not terminate the call. 

21. Enable/Disable Alternate Switch Action (

Q

1, 

Q

2)

With “

Q

6” (factory default) programmed the Remote Access Operation Commands (

Q

0 and 

Q

1) to Un-Latch or Latch the relay are

enabled.

With “

Q

7” programmed the Remote Access Operation Commands (

Q

0 and 

Q

1) to Un-Latch or Latch the relay are disabled. Disabling

the Latch commands can be useful in applications where you want to eliminate the possibility of inadvertently entering a latch com-
mand leaving a gate open/closed, etc.

22. Enable/Disable Relay Latching Commands (

Q

6, 

Q

7)

Entering ### in programming will reset all of the Quick Programming Features back to their factory default settings. 

Note: 

The ###

command will not change or reset your IP settings.

23. Reset All Quick Programming Features (###)

14

The In-Band Audio Call Progress Detection can be set to 0 or 1 (0 = OFF, 1 = ON, factory set to 0) by entering the single digit then
the memory location 

#29

. In-Band Audio Call Progress detection should be turned ON in applications where you are making an out-

bound call through your VoIP phone system and are relying on In-Band analog audio detection of the distant party answering to turn
on the call connected LED and/or play the location ID message on Emergency VoIP phones.

16. In-Band Audio Call Progress Detection (#29)

Summary of Contents for E-60-BK-IP

Page 1: ...875 x 4 938 x 0 17 Phone 72mm x 46mm x 42mm 2 84 x 1 8 x 1 65 Shipping Weight 0 55 kg 1 2 lbs Operating Temperature 40 C to 60 C 40 F to 140 F Humidity Standard Products 5 to 95 non condensing Humidit...

Page 2: ...vice Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Expres...

Page 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Page 4: ...oller etc not connected Push Button Switch Push to initiate call push again to disconnect Solid 316 stainless steel internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to pr...

Page 5: ...n mounting to vinyl siding Step 3 Cut a hole through the siding and wall sheathing just large enough for the rough in box Caution Too large of a hole can cause plate misalignment and compromise the ga...

Page 6: ...ional VE 5x5 Surface Mount Box with black satin powder paint finish not included DOD 424 Optional VE LIGHT kit can be used to illuminate the faceplate when used with a VE 5x5 DOD 428 WARNING Do NOT us...

Page 7: ...tors for use when replacing E 60 EWP circuit boards Optional 2 Amp Relay Output Contacts Connector Connect to doorstrike mag lock gate controller etc 3 1 10 1 Step 1 Cut wires from J1 10 pin connector...

Page 8: ...nal version first via Add and Remove Programs To start the Viking VoIP Phone Programming application click on the Viking VoIP Phone Programming icon on your desk top The Main screen will appear allowi...

Page 9: ...n the E 60 IP phone answers enter the 6 digit security code factory set to 845464 see section B A double beep should then be heard indicating you have entered the programming mode Step 3 You can now t...

Page 10: ...digits 24 Relay Activation Time 2 digits 00 99 sec 00 0 5 sec factory set to 05 2 digits 00 99 25 Relay Mode 0 Door Strike 1 Outbound Call 2 In Outbound Call 3 Doorbell 4 LV 1K Control 5 Ring 6 Ring...

Page 11: ...ation number 00 04 To clear a speed dial location simply enter the memory location 00 04 alone The E 60 IP phone is factory set with no speed dial number pro grammed To Program Enter Q QQ Q 0 1 2 9 0...

Page 12: ...sy is detected the E 60 IP phone will dial the next programmed speed dial number and continue to cycle through the numbers until a call is com pleted Notes This feature is enabled in the factory defau...

Page 13: ...m the Entry phone This mode is useful for activating strobe lights for Emergency VoIP phones 2 Inbound Outbound Call Mode When programmed for Inbound Outbound Call Mode the relay will activate continu...

Page 14: ...of the following three modes 0 OFF Silent Monitoring Mode In the OFF mode the speaker is disabled at all times However the speaker can be enabled after communication has been established by entering t...

Page 15: ...tion Activate Relay QQ or ___ ___ Momentarily activate relay 1 or 2 digits factory set to QQ Un Latch Relay Q0 Un latch deactivate the relay Latch Relay Q1 Latch continuously activate the relay Discon...

Page 16: ...ications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mount an...

Page 17: ...EAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any auth...

Reviews: