The microphone volume can be set from 1 to 9 (1 = lowest volume setting, 9 = the highest, factory set to 5) by entering the single
digit then the memory location 

#22

. Alternatively the microphone can be placed in the “ANC” Automatic Noise Cancelling mode by

entering 

0#22

in programming. With the mic in the ANC mode, when background noise increases, the mic gain will automatically de-

crease. When background noise decreases the mic gain will automatically increase. The ANC mode is useful in applications where
the background noise level can change drastically such as a gas car running vs a diesel truck.

9.  Mic Volume/Automatic Noise Cancelling Mode (#22)

The speaker volume can be set from 0 to 9 (0 = lowest volume setting, 9 = the highest, factory set to 5) by entering the single digit
then the memory location 

#23

. Alternatively the speaker can be turned off for silent monitoring by entering 

0#31

(see Speaker Mode

section 19).

10. Speaker Volume (#23)

The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being called must
enter on their phone in order to actuate the relay (door strike/mag-lock/gate controller, etc). The code can contain the numbers 0 - 9,
00 - 99, ## or 

QQ

(factory default). The code must not match the first 1 or 2 digits of the security code. To program the code to “##”

you must enter 

Q

#

Q

# #24

in programming. To program the code to “

QQ

” you must enter 

QQQQ

#24

in programming. To disable this

feature enter 

#24

without any preceding digits. The code must be entered while the remote phone is communicating with the Emer-

gency/Entry phone. The Emergency/ Entry phone determines which direction the touch tone is coming from and only responds to
touch tones from the called phone. 

11. Relay Activation Command (#24)

The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct touch tone command
is entered. This two digit number can range from 01 to 99 seconds, or enter 00 for 0.5 seconds. The factory setting is 5 seconds.

12. Relay Activation Time (#25)

The 2 amp relay contacts can be programmed to one of five different modes by entering 

0,1,2,3 or 4 #26

in programming.

0 = Doorstrike Mode. 

When programmed for Doorstrike Mode the relay will momentarily activate for the preprogrammed relay ac-

tivation time after detecting the correct relay activation command (one or two digit touch tone) from the called party.

1 = Outbound Call Mode.

When programmed for Outbound Call Mode the relay will activate continuously for the duration of any

outbound call from the Entry phone. This mode is useful for activating strobe lights for Emergency VoIP phones.

2 = Inbound/Outbound Call Mode. 

When programmed for Inbound/Outbound Call Mode the relay will activate continuously for the

duration of any inbound or outbound call from the Entry phone. This mode is useful for turning on IR flood lights, for VoIP phones
with cameras, etc. 

3 = Doorbell Mode. 

When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay

activation time on any outbound call from the Entry phone. This mode is useful for activating a door chime, etc. When activating door
chimes, a 0.5 - 1 second relay activation time is recommended.

4 = LV-1K Control Mode. 

When programmed for 

LV-1K

Control Mode the relay will activate continuously while the Emergency/Entry

phone is powered and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, ac-
tivating 

LV-1K

’s flashing LED and audible beep signals. 

5 = Loud Ring Mode. 

When programmed for Loud Ring Mode the relay will continuously activate while the ringing extension is

called. This mode is useful for activating a Viking model 

SL-2

strobe light, etc.

6 = Loud Ring Flash Mode. 

When programmed for Loud Ring Flash Mode the relay will momentarily turn on and off in a 400ms

on/off cadence while the ringing extension is called. This mode is useful for activating a Viking 

LPL-1

Remote Visual Indicator, etc.

13. Relay Mode (#26)

The relay activation tone is a buzzing sound that is heard at the Entry phone when the door strike relay is activated. After the called
party enters the correct relay activation command, the called party will hear 2 short confirmation beeps and the entry phone will
output a buzzing sound (relay activation tone) while the door strike relay is activated. The tone (buzz) length will match the relay ac-
tivation time up to a maximum of 5 seconds. The tone (buzz) can be programmed to three different volume settings 1 = Low, 2=
Medium, 3 = High in memory location #27. The tone can also be turned off/disabled by entering 0#27.

14. Relay Activation Tone (Buzz) Volume (#27)

The In-Band Audio Detection Sensitivity can be set from 1 to 9 (1 = minimum setting, 9 = the highest, factory set to 5) by entering the
single digit then the memory location #28. Increasing or decreasing the sensitivity may be required in applications where you are
making an outbound call through your VoIP phone system and are relying on In-Band audio detection of the distant party answering
to turn on the call connected LED and/or play the location ID message on Emergency VoIP phones. 

Note: 

Power cycling the unit is

required after touch tone programming this feature.

15. In-Band Audio Detection Sensitivity (#28)

13

Summary of Contents for E-60-BK-IP

Page 1: ...875 x 4 938 x 0 17 Phone 72mm x 46mm x 42mm 2 84 x 1 8 x 1 65 Shipping Weight 0 55 kg 1 2 lbs Operating Temperature 40 C to 60 C 40 F to 140 F Humidity Standard Products 5 to 95 non condensing Humidit...

Page 2: ...vice Provider 3COM VCX X 3CX X Aastra X Asterisk X Atcom X Avaya IP Office X BlueBox X Brekeke X Callcentric X Cisco Unified Communications Manager CUCM X X Cisco Unified Communications Manager Expres...

Page 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Page 4: ...oller etc not connected Push Button Switch Push to initiate call push again to disconnect Solid 316 stainless steel internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to pr...

Page 5: ...n mounting to vinyl siding Step 3 Cut a hole through the siding and wall sheathing just large enough for the rough in box Caution Too large of a hole can cause plate misalignment and compromise the ga...

Page 6: ...ional VE 5x5 Surface Mount Box with black satin powder paint finish not included DOD 424 Optional VE LIGHT kit can be used to illuminate the faceplate when used with a VE 5x5 DOD 428 WARNING Do NOT us...

Page 7: ...tors for use when replacing E 60 EWP circuit boards Optional 2 Amp Relay Output Contacts Connector Connect to doorstrike mag lock gate controller etc 3 1 10 1 Step 1 Cut wires from J1 10 pin connector...

Page 8: ...nal version first via Add and Remove Programs To start the Viking VoIP Phone Programming application click on the Viking VoIP Phone Programming icon on your desk top The Main screen will appear allowi...

Page 9: ...n the E 60 IP phone answers enter the 6 digit security code factory set to 845464 see section B A double beep should then be heard indicating you have entered the programming mode Step 3 You can now t...

Page 10: ...digits 24 Relay Activation Time 2 digits 00 99 sec 00 0 5 sec factory set to 05 2 digits 00 99 25 Relay Mode 0 Door Strike 1 Outbound Call 2 In Outbound Call 3 Doorbell 4 LV 1K Control 5 Ring 6 Ring...

Page 11: ...ation number 00 04 To clear a speed dial location simply enter the memory location 00 04 alone The E 60 IP phone is factory set with no speed dial number pro grammed To Program Enter Q QQ Q 0 1 2 9 0...

Page 12: ...sy is detected the E 60 IP phone will dial the next programmed speed dial number and continue to cycle through the numbers until a call is com pleted Notes This feature is enabled in the factory defau...

Page 13: ...m the Entry phone This mode is useful for activating strobe lights for Emergency VoIP phones 2 Inbound Outbound Call Mode When programmed for Inbound Outbound Call Mode the relay will activate continu...

Page 14: ...of the following three modes 0 OFF Silent Monitoring Mode In the OFF mode the speaker is disabled at all times However the speaker can be enabled after communication has been established by entering t...

Page 15: ...tion Activate Relay QQ or ___ ___ Momentarily activate relay 1 or 2 digits factory set to QQ Un Latch Relay Q0 Un latch deactivate the relay Latch Relay Q1 Latch continuously activate the relay Discon...

Page 16: ...ications Note The VE 3x5 is not compatible with the VE GNP pedestals The VE PNL s are VE Series backboxes with a blank aluminum panel The user can customize the clear coated aluminum panel to mount an...

Page 17: ...EAR LIMITED WARRANTY Viking warrants its products to be free from defects in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any auth...

Reviews: