background image

10

LEG LEVELER INSTALLATION

READ BEFORE INSTALLING LEG LEVELERS

W

WA

AR

RN

NIIN

NG

G!!

Do not lay unit on top, side, back, or front.  If unit is accidentally laid in any position other than right side up, then the
unit must remain in the right side up position for at least 24 hours before plugging the unit in.

1.  Tip unit backwards so there is (1) foot of clearance on front of the unit.  Have someone to assist you in tilting the

unit, to prevent it from falling on you while installing the leg levelers.

2.  Screw front two leg levelers into the screw impressions.  Leg levelers shoudl be screwed in until snug.
3.  Repeat steps 1 & 2, with the exception of tipping the unit forwards now, to screw in the back two leg levelers.
4.  Your leg levelers are now installed.
5.  The unit should be level from front to back and side to side.  If floor conditions do not allow the unit to sit level,

adjust leg leveler(s) by turning the required leg leveler(s) counter-clockwise to increase their height and clockwise to
reduce their height. 

Screw
Impressions

Summary of Contents for Designer DUAR140

Page 1: ...be ev ve er ra ag ge e c ce en nt te er r i is s located so the front is not blocked to restrict incoming or discharge air flow properly leveled located in a well ventilated area connected to the proper kind of outlet with the correct electric supply and grounding A 115 volt 60 Hz 15 amp fused electrical supply is required N NO OT TE E Time delay fuse or circuit breaker is recommended not used by ...

Page 2: ...ERCOUNTER CABINET CUTOUT A A 15 38 1 cm B B Min 34 1 2 87 6 cm Max 35 1 8 89 2 cm C C Min 24 61 0 cm C 15 38 1 cm width for cabinet only If door is recessed between cabinets cabinet cutout must be 15 1 4 38 7 cm ...

Page 3: ...r ri ic c D Da at ta a 115 VAC 60 Hz Maximum amps 3 0 Approximate Shipping Weight 110 lbs 49 5 kg Front View Side View 30 3 4 78 1 cm Min 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 14 3 4 37 5 cm 21 3 16 53 8 cm 23 5 8 60 0 cm 26 1 8 66 4 cm 37 3 16 94 5 cm ...

Page 4: ...roximate shipping weight 110 lbs 49 5 kg Front View Side View DUAR Side View DFUR 30 3 4 78 1 cm Mín 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully extended 14 3 4 37 5 cm 21 3 16 53 8 cm 23 5 8 60 0 cm 24 5 8 62 5 cm 21 3 16 53 8 cm 23 7 16 59 5 cm 37 3 16 94 5 cm 37 3 16 94 5 cm to front of locally supplied custom panel ...

Page 5: ...acing unit in proper place N No ot te e H Hi in ng ge e b br ra ac ck ke et t l lo oc ca at ti io on n s sh ho ow wn n i is s f fo or r r ri ig gh ht t h hi in ng ge e s sw wi in ng g Door swing pin Top hinge bracket Logo Bottom hinge bracket Light switch activator REVERSIBLE DOOR Glass Door Units Only PROFESSIONAL SERIES You can change the door swing from right to left hinge very easily 1 Simply ...

Page 6: ...or with the 10 32 machine screws and a 1 8 allen head driver as shown in Figure 1 below 2 Press in the shoulder bushings to the top and bottom door hinge brackets Make certain that the shoulder is to the outside of the door as shown in Figure 1 below 3 Test fit the door to the unit to make certain door will hang correctly The door is hung correctly when the top of the door is parallel to the top o...

Page 7: ...oor 1 4 X 3 8 Deep hinge screw clearance hole Locate and drill using door hinge hole after the door has been aligned to the unit and when the wood is positioned on door Mounting surface Non face side Mounting surface non face side Mounting surface non face side Min 5 8 1 7 cm Max 3 4 1 9 cm 14 15 16 36 4 cm 7 5 32 18 2 cm 23 32 1 8 cm TYP 1 23 32 4 4 cm min width to cover door extrusion 23 32 1 8 ...

Page 8: ...1 4 X 3 8 Deep hinge screw clearance hole Locate and drill using door hinge hole after the door has been aligned to the unit and when the wood is positioned on door Mounting surface Non face side Mounting surface non face side Mounting surface non face side Min 5 8 1 7 cm Max 3 4 1 9 cm 14 15 16 36 4 cm 7 5 32 18 2 cm 23 32 1 8 cm TYP 1 23 32 4 4 cm min width to cover door extrusion 23 32 1 8 cm T...

Page 9: ...Attach the door light striker plate as shown using the 5 16 hex or phillips head screws provided Make certain the light is able to turn on and off when the door is opened and closed 9 Attach the door to the unit by reversing step number 1 above CAUTION Door can become disengaged if washers are not installed CAUTION Door can become disengaged if washers are not installed Cabinet Hinge Wood Frame Do...

Page 10: ...tilting the unit to prevent it from falling on you while installing the leg levelers 2 Screw front two leg levelers into the screw impressions Leg levelers shoudl be screwed in until snug 3 Repeat steps 1 2 with the exception of tipping the unit forwards now to screw in the back two leg levelers 4 Your leg levelers are now installed 5 The unit should be level from front to back and side to side If...

Page 11: ... listed refrigerated products are equipped with this type of plug Power Supply with 3 prong grounding plug Grounding type wall receptacle FINAL PREPARATION 1 Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior of the refrigerated beverage center should be washed thoroughly with hot soapy water rinsed and wiped dry to remove film residue and any insta...

Page 12: ...io on ns s After making a temperture adjustment allow 24 hours for your refrigerated beverage center to reach a new temperature setting The motor will start and stop often It must do this to maintain the temperature setting Unplug the refrigerated beverage center before working on anything with the electrical system Exercise caution when sweeping vacuuming or mopping near the front of the unit Dam...

Page 13: ...s I In nt te er ri io or r Wash interior compartment with mild soap and water Do not use abrasive powder solvent polish cleaner or undiluted detergent S St ta ai in nl le es ss s S St te ee el l P Pa ar rt ts s All stainless steel parts should be wiped regularly with hot soapy water Use a liquid cleaner designed for stainless steel when soapy water will not do the job D Do o n no ot t u us se e st...

Page 14: ...o on n o of f p pa ar rt ts s u us se e o on nl ly y a au ut th ho or ri iz ze ed d p pa ar rt ts s t to o e en ns su ur re e p pr ro ot te ec ct ti io on n u un nd de er r t th he e w wa ar rr ra an nt ty y T Th hi is s m ma an nu ua al l s sh ho ou ul ld d r re em ma ai in n w wi it th h t th he e r re ef fr ri ig ge er ra at to or r f fo or r f fu ut tu ur re e r re ef fe er re en nc ce e TROUB...

Page 15: ...roper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental damage whether arising out ...

Page 16: ...r to the product for any reason alteration improper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequen...

Reviews: