background image

Installation 

Paging port 

output of

PABX/KSU

PA-2A Paging/Loud Ringing

Amplifier System

Common

Siren

Evacuation Signal

Doorbell

Dry Contact Closures from Alarm

Equipment, Doorbell Switch, Etc.

S6

S7

S5

C

LED1

C

LED6

C

LED2

C

LED3

C

LED5

C

LED4

1

3

4

2

ON

5

C

LED7

VIKING

MODEL CTG-1A

POWER 13.8V AC 

VOLUME

SINGLE

CANCEL

DOUBLE

+

TRIPLE

MODE

CLOCK CONTROLLED

TONE GENERATOR

VIKING

ELECTRONICS

HUDSON, WI 54016 

1 2 3 4 5

SCHEDULE 2

BUZZ

RELAY MODE

DST

60 HZ

©

PWR

 

VIKING

©

VIKING

ELECTRONICS

HUDSON, WI 54016

PAGING - LOUD RINGING

AMPLIFIER SYSTEM

POWER 13.8V AC

MODEL PA-2A

 

PAGING

VOLUME

RINGING
VOLUME

 

MIN

MAX

MIN

MAX

1

2

3

4

5

6

7

8

9 10

N

IG

H

T

T

R

A

N

S

F

E

R

P

A

G

IN

G

H

O

R

N

6

0

0

 O

H

M

A

U

D

IO

 O

U

T

T

R

U

N

K

 O

R

P

A

G

IN

G

 P

O

R

T

L

O

U

D

 R

IN

G

T

R

IG

G

E

R

 I

N

P

U

T

1 - 3

4 - 6

RINGING LINES

W

A

RBLE

 

/

 

CHIME

1 2 3 4 5 

AUDIO LOADING

T

A

LK BA

TTER

Y

ALERT T

O

NE

Connect the 

CTG-1A

between your phone system and your paging amplifier as shown in the diagram below. 

Programming

A.  Setting the Clock Time

B.  Setting the Day of the Week

Step 1.

Press the 

MODE

button repeatedly until the 

TIME

indicator lights.

Step 2.

Increase or decrease the clock time by pressing the 

+

or 

-/CANCEL

button until the

desired time is displayed. Press and hold the 

+

or 

-/CANCEL

button to speed up the

selection.

Step 3.

Leave the set time mode by pressing the 

MODE

button.

Notes:

See Programing section O, Daylight Savings Time for the correct setting of dip switch 4 for the current

time of year. If the clock time has been adjusted using the + or -/CANCEL buttons, the clock will then start to run
the moment you leave the time mode, allowing you to synchronize the 

CTG-1A

with your building clocks.

Note: 

Steps B and C are only required if you want to turn off the Alert Tones on certain days of the week

.

Note: 

The day of week setting is a one set up and does not need to be reset unless you experience a power

failure longer than backup time of 4 days. To reset the day of week, repeat steps 1 – 3 in section B.

Step 1.

Press the 

MODE

button repeatedly until the 

DAYS

indicator lights.

Step 2.

A flashing “

A

” (without “on” or “of” displayed) indicates today’s day has not been set (or

power was lost for more than 4 days).  The day of week has already been set if a
flashing “

A

” plus “

on

”, flashing “

A

” plus “

of

” or flashing number (1-7) plus “on” or “of”

are displayed.

Step 3.

Select today’s day of the week using the 

TIME

(

+

and 

-/CANCEL

) buttons.  As a general

rule, Sunday is day 1 and Saturday is day 7.  When today’s day of the week is flashing
on the display, set it by pressing the 

DOUBLE

alert tone button. A confirmation beep

will be heard and today’s day number and “on” or “of” will now be displayed.  

3

Summary of Contents for CTG-1A

Page 1: ...ly forward entry calls at certain times of the day Power 120V AC 13 8V AC 1 25A UL listed adapter provided Dimensions 5 25 x 3 6 x 1 75 133mm x 91mm x 44mm Weight 2 lbs 0 9 Kg Operating Temperature 32...

Page 2: ...er setting an event time press SINGLE DOUBLE or TRIPLE to program 1 2 or 3 alert bongs buzzer sounds for that event time Timed Relay Mode After setting an event time press SINGLE to turn the relay on...

Page 3: ...CEL button to speed up the selection Step 3 Leave the set time mode by pressing the MODE button Notes See Programing section O Daylight Savings Time for the correct setting of dip switch 4 for the cur...

Page 4: ...Set dip switch 3 to off to program specific days to on or off in schedule 1 Step 3 With the day of the week flashing use the TIME and CANCEL buttons to select the day of the week you would like to se...

Page 5: ...r off event Press and hold the or CANCEL to speed up the selection Step 4 Press the single ALERT TONE button if the displayed time is a relay on event time or the double or triple ALERT TONE buttons i...

Page 6: ...When finished programming press the MODE button until the RUN indicator lights In the run mode all buttons except the MODE button are disabled and the current time will be displayed with the colon fl...

Page 7: ...rate Day of Week programming Note The schedule selection should only be changed in the Time Mode With DIP switch 2 in the OFF positon the CTG 1A will produce the selected tones at the programmed times...

Page 8: ...rogrammed in that schedule The Timed Relay Mode of the CTG 1A changes its operation to a clock controlled relay output device allowing the relay to be programmed to turn on or off at certain times of...

Page 9: ...cond break then repeated a second time 3 second break then repeated a second time Triple E Evacuation Signal Temporal Slow Whoop D Siren Yelp C Doorbell Ding Dong On Off 300 ms 300 ms 300 ms 280 Hz 22...

Page 10: ...Model C 250 Entry PhoneController with Call Forwarding DOD 172 S6 S7 S5 C LED1 C LED6 C LED2 C LED3 C LED5 C LED4 1 3 4 2 ON 5 C LED7 VIKING MODEL CTG 1A POWER 13 8V AC VOLUME SINGLE CANCEL DOUBLE TR...

Page 11: ...A POWER 13 8V AC VOLUME SINGLE CANCEL DOUBLE TRIPLE MODE CLOCK CONTROLLED TONE GENERATOR VIKING ELECTRONICS HUDSON WI 54016 1 2 3 4 5 SCHEDULE 2 BUZZ RELAY MODE DST 60 HZ To switch or controller that...

Page 12: ...LE OR USE OF THE PRODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY...

Reviews: