background image

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries
assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

Fax Back Doc 159

ZF302520 Rev A

Printed in the U.S.A.

P

P

r

r

o

o

d

d

u

u

c

c

t

t

S

S

u

u

p

p

p

p

o

o

r

r

t

t

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

6

6

6

6

6

6

F

F

a

a

x

x

B

B

a

a

c

c

k

k

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

4

4

3

3

4

4

5

5

C.  Provide 4 Door Entry Points with Keyless Entry (or Optional Card Readers) for up to 250 

Apartments or Offices

The 

C-4000

converts any four Touch Tone phones  into multi-number auto dialers that will store up to 250 telephone numbers in

non-volatile memory.  Use with Viking’s 

K-1705-3

phone to provide vandal resistant handsfree or handset communication from entry

points to apartments or offices. When a call initiated by the 

C-4000

is answered by an apartment or business tenant, a built-in con-

tact closure may be activated to control an electric gate or door strike. Up to 250 entry codes may also be programmed providing
tenants with keyless entry or optional 

HID-1

Card Readers may be added for Proxy card entry. The 

C-4000

can be programmed

locally or remotely using a standard Touch Tone phone.  The 

C-4000

has built-in user dialing restriction to help prevent unauthorized

calls and toll fraud.

C.O. Line or Analog

PABX/KSU Station

Local

Programming

Phone

13.8V AC

Adapter

Included

120V AC

Power typically not required
for gate controllers.

Doorstrike/Magnetic Lock 

(not included)

Power Supply

5A@30VDC/250VAC

maximum

(not included)

A contact closure output is available

for each entry phone. 

VIKING

©

MODEL C-3000

VIKING

ELECTRONICS

HUDSON, WI 54016

12 UNIT APARTMENT

ENTRY CONTROLLER MODULE 

POWER

13.8 VAC

3 4 5 6 7

1 2

DOOR

STRIKE

1

DOOR

STRIKE

2

DIP

SWITCH

1  2  3

RJ21X

12 APARTMENT LINES IN/OUT

8

ENTRY 1

ENTRY 2

OUT

IN

MULTI-MODULE

INTERCONNECT

POSTAL

LOCK
INPUT

Optional C-3000 (not included)

If some tenants do not have C.O. phone service, the 
Viking model C-3000 can be added to ring up to 12 
tenant's phones. Up to eight C-3000 units can be 
cascaded to support a total of 96 "No C.O." tenants.

Analog Entry Phone

K-1705-3

Optional "Push to Open / Request to Exit"

Button 

(not included)

Entry Points 2-4 should 
be wired identical to Entry 
Point 1 as shown.

The K-1705-3 is shown with 
optional VE-6x7 backbox.

Viking D-Series Directory

(not included)

N.O.  COM  N.C.

DOOR STRIKE 1

VIKING

©

MODEL C-4000 

VIKING

ELECTRONICS

HUDSON, WI  54016

APARTMENT OR OFFICE

ENTRY CONTROLLER

PROGRAM

PHONE

POWER

13.8 VAC 

DOOR STRIKE RELAYS

WIEGAND INPUTS

C

LED1

N.O.  COM  N.C.

DOOR STRIKE 2

N.O.  COM  N.C.

DOOR STRIKE 3

N.O.  COM  N.C.

DOOR STRIKE 4

BLK  RED  GRN  WHT

ENTRY 1

BLK  RED  GRN  WHT

ENTRY 2

BLK  RED  GRN  WHT

ENTRY 3

BLK  RED  GRN  WHT

ENTRY 4

C.O. LINE

INPUT

AUX

LINE

ENTRY

PHONE 1

ENTRY

PHONE 2

ENTRY

PHONE 3

ENTRY

PHONE 4

REX

1

REX

2

REX

3

REX

4

H        L

LOG BUS

RS-232 PORT

PROGRAM

PHONE

Viking HID-1

Proximity Card Reader

(not included)

Viking HID-2 Keypad

(not included)

- or -

* 1219m (4000 ft) max

* 609m (2000 ft) max

?

Need More Information on Directories?

Call (715) 386-4345 and select 158.

?

Need More Information on VE Backboxes?

Call (715) 386-4345 and select 424.

?

Need More Information on the HID-2?

Call (715) 386-4345 and select 199.

?

Need More Information on the HID-1?

Call (715) 386-4345 and select 197.

IMPORTANT:

Electronic devices are susceptible to lightning and power station

electrical surges from both the AC outlet and the telephone line.  It is recommend-
ed that a surge protector be installed to protect against such surges.  Contact
Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.

!

* Note

: Maximum Wiegand run length is 2000 feet using 24 gauge wire when using the Viking Model 

HID-1

proxy card reader, and 4000 feet for the 

HID-

2

keypad. Run length is reduced to half if two share the same wire run from the same 

C-4000

entry point. Run length will also be reduced if using a

Wiegand device other than the Viking Model 

HID-1

, that requires more than 35mA average operating current. Run lengths can be doubled by doubling up

on the BLACK and RED 24 gauge wire, or using 21 gauge (or larger) wire. Certain electrically noisy locations might require shielded wire.

8

Summary of Contents for C-4000

Page 1: ...ection EWP conforms to NEMA requirements Yellow in use LED Telephone line powered Volume adjustments for microphone and speaker Advanced call progress detection disconnects on busy signal return to di...

Page 2: ...g call In most but not all areas the sum of the REN s should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as deter mined by the total REN s contact the lo...

Page 3: ...Button Switch Push to initiate call push again to disconnect Solid 304 stainless steel internally sealed per IP67 Call VIKING 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WXY 0 OPER Color Video Camer...

Page 4: ...Number 156 Optional C 3000 Apartment Entry System not included Fax Back Number 162 Note To increase surge protection loosen the PCB mount ing screw labeled as shown right and fasten a wire with spade...

Page 5: ...e such as RG6 is recom mended D Adjusting the Camera The camera can be tilted and rotated to your desired position A portable service test monitor can be used to determine the correct viewing angle du...

Page 6: ...1705 3 will output 3 beeps and automatically hang up after detecting any of the following busy signal standard or fast reorder CPC short break in line current when called party hangs up return to dia...

Page 7: ...1B AUX TRIG INPUT 18 VDC 200mA POWER 13 8 VAC PROGRAMMING OFF ON C O Line or Analog PABX KSU Station 13 8V AC Adapter Provided 120V AC K 1705 3 Doorstrike Magnetic Lock Relay Contact Specifications 5A...

Page 8: ...3000 not included If some tenants do not have C O phone service the Viking model C 3000 can be added to ring up to 12 tenant s phones Up to eight C 3000 units can be cascaded to support a total of 96...

Reviews: