background image

VIKING

Model:

K-1705-3

261102-1

Serial No:

REN: 1.0B

XXXXXXXX

Viking Electronics, Inc.    (715)  386-8861

1531 Industrial St., Hudson, WI  54016

P/N:

DEV:

Complies with FCC Part 15 and 68 Reg. No: AH3USA-32531-TE-E

RoHS

5.5”

4.04”

6.5”

5.12”

** Gel-Filled

Butt Connectors

(included)

VIKING

©

MODEL C-3000

VIKING

ELECTRONICS

HUDSON, WI 54016

12 UNIT APARTMENT

ENTRY CONTROLLER MODULE

POWER

13.8 VAC

33 44 55 66 77

11 22

DOOR

STRIKE

1

DOOR

STRIKE

2

DIP

SWITCH

1  2  3

RJ21X

12 APARTMENT LINES IN/OUT

88

ENTRY 1

ENTRY 2

OUT

IN

MULTI-MODULE

INTERCONNECT

POSTAL

LOCK
INPUT

APARTMENT E NTRY

SYSTEM

VIKING

ELECTRONICS

HUDSON, WI 54016

VIKING

©

MODEL  K-1900-3

LINE I N     P

HONE

POWER 13.8 V AC

OFF     O

N

18 V DC
200

m

A

-      +

AUX.

TRIG.

INPUT

RELAY  CONTACTS

1A

1B

PROGRAMMING

1      2      3      4      5       6      7      8      9     10

or

or

or

* C.O. Line

or Analog 

PABX/KSU

Station

Spade
Terminal
(included)

*** Earth

Ground

(optional)

Red (Ring)

Green (Tip)

or

N.O.  COM  N.C.

DOOR STRIKE 1

VIKING

©

MODEL C-4000 

VIKING

ELECTRONICS

HUDSON, WI 54016

APARTMENT OR OFFICE

ENTRY CONTROLLER

PROGRAM

PHONE

POWER

13.8 VAC

DOOR STRIKE RELAYS

WIEGAND INPUTS

C

LED1

N.O.  COM  N.C.

DOOR STRIKE 2

N.O.  COM  N.C.

DOOR STRIKE 3

N.O.  COM  N.C.

DOOR STRIKE 4

BLK  RED  GRN  WHT

ENTRY 1

BLK  RED  GRN  WHT

ENTRY 2

BLK  RED  GRN  WHT

ENTRY 3

BLK  RED  GRN  WHT

ENTRY 4

C.O. LINE

INPUT

AUX

LINE

ENTRY

PHONE 1

ENTRY

PHONE 2

ENTRY

PHONE 3

ENTRY

PHONE 4

REX

1

REX

2

REX

3

REX

4

H        L

LOG BUS

RS-232 PORT

PROGRAM

PHONE

VIKING

©

MODEL C-2000A

VIKING

ELECTRONICS

HUDSON, WI  54016

ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER

1     2     3     4     5

6 7 8 9 10

11 12 13 14 15

16 17 18 19 20

21 22 23 24 25

26 27 28 29 30

PWR 13.8 V

A

C

E

ARTH 

G

N

D

E

NTR

Y

 PH

O

NE 1

DOO

S

TRIKE 

1

E

NTR

Y

 PH

O

NE 

2

DOO

S

TRIKE 2

E

NTR

Y

 PH

O

NE 

3

DOO

S

TRIKE 

3

E

NTR

Y

 PHONE 4

DOO

S

TRIKE 

4

D

OORBELL

 SWITCH 

/

AUX

INPUT

AUX. CONT

ACT

OUTPU

T

P

HONE LIN

E

INPUT

L

INE OUT

T

O

 PHONES

J1

Rear View of the K-1705-3

Optional K-1900-3 Apartment

Entry Dialer 

(not included)

Fax Back Number 312

Optional C-2000A Advanced Door

Entry Controller 

(not included)

Fax Back Number 156

Optional C-3000 Apartment

Entry System 

(not included)

Fax Back Number 162

*** Note:

To increase surge protection, loosen the PCB mount-

ing screw labeled         (as shown right) and fasten a wire with
spade terminal (included) from the mounting screw to Earth
Ground (grounding rod, water pipe, etc.)

** Note:  

The gel-filled (water-tight)

butt connectors are designed for insu-
lation displacement on 19-26 gauge
wire with a maximum insulation of
0.082 inches. Cut off the stripped wire
ends prior to terminating.

* Note:

When installing a line powered phone on a low voltage and/or low

loop current phone system extension, a 

TBB-1

Talk Battery Booster may

be required.

?

Need More Information on the TBB-1?

Call (715) 386-4345 and select 630.

Optional C-4000 Apartment/

Office Entry Controller 

(not

included) 

Fax Back Number 164

B. Wiring the K-1705-3 Phone Board

C. Wiring the K-1705-3 Camera

1. Using RG59 for Video and CAT5 for Camera Power and Phone Board Audio (Recommended)

VIKING

Model:

K-1705-3

261102-1

Serial No:

REN: 1.0B

XXXXXXXX

Viking Electronics, Inc.    (715)  386-8861

1531 Industrial St., Hudson, WI  54016

P/N:

DEV:

Complies with FCC Part 15 and 68 Reg. No: AH3USA-32531-TE-E

RoHS

Back View of the K-1705-3

** Camera Pwr (+)  

O/W

** Camera GND (-)  

W/O

Yellow (Video)

Up to 1000 ft

3-Wire Gel-Filled Butt Connectors 

included (3M Scotchlok UR2)

CAT5 Cable

To unused input on TV, 
VHF modulator, whole 
house video distribution 
equipment, etc.

120V AC

Camera GND (-)

Camera Power (+)

Black with
White Stripe

6V DC Adapter

(included)

Black

(-)

!

(+)

Phone Board Audio In/Out (Tip)    

W/BL

Phone Board Audio In/Out (Ring)    

BL/W

See page 4, section B

Wiring Phone Board

BL/W         W/BL

W/O

O/W

*** RG59 or RG6 

Shielded

Video Cable

Center conductor
stripped back 5/8"

Twisted foil and 
braided shield

** Up to 500 ft

"F"

Connector

"F" to Phono Plug 

Adapter 

(Radio

Shack part #278-252)

- Black (GND)

+ Red (6VDC)

Crimp-on Splice 

Connectors (not included)

Green

Red

IMPORTANT:

Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet

and the telephone line.  It is recommended that a surge protector be installed to protect against such surges.  Contact
Panamax at (800) 472-5555 or Electronic Specialists Inc. at (800) 225-4876.

!

4

Summary of Contents for C-4000

Page 1: ...ection EWP conforms to NEMA requirements Yellow in use LED Telephone line powered Volume adjustments for microphone and speaker Advanced call progress detection disconnects on busy signal return to di...

Page 2: ...g call In most but not all areas the sum of the REN s should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as deter mined by the total REN s contact the lo...

Page 3: ...Button Switch Push to initiate call push again to disconnect Solid 304 stainless steel internally sealed per IP67 Call VIKING 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WXY 0 OPER Color Video Camer...

Page 4: ...Number 156 Optional C 3000 Apartment Entry System not included Fax Back Number 162 Note To increase surge protection loosen the PCB mount ing screw labeled as shown right and fasten a wire with spade...

Page 5: ...e such as RG6 is recom mended D Adjusting the Camera The camera can be tilted and rotated to your desired position A portable service test monitor can be used to determine the correct viewing angle du...

Page 6: ...1705 3 will output 3 beeps and automatically hang up after detecting any of the following busy signal standard or fast reorder CPC short break in line current when called party hangs up return to dia...

Page 7: ...1B AUX TRIG INPUT 18 VDC 200mA POWER 13 8 VAC PROGRAMMING OFF ON C O Line or Analog PABX KSU Station 13 8V AC Adapter Provided 120V AC K 1705 3 Doorstrike Magnetic Lock Relay Contact Specifications 5A...

Page 8: ...3000 not included If some tenants do not have C O phone service the Viking model C 3000 can be added to ring up to 12 tenant s phones Up to eight C 3000 units can be cascaded to support a total of 96...