8
C. Programming Examples
CCTV Inactive (Idle State) Modes:
D. Door Strike Activation Code
To Program the C-1000B...
Enter
1.
...to set door strike 1 to activate for 3 seconds
03 #01
2.
...to set the auxiliary contacts to activate an external ringer or strobe light in a custom ring
cadence while either doorbox is ringing
12 #03
3.
...to have doorboxes ring phones in a custom ring pattern
Q
2
4.
...to have a door strike activation code be “55”
55#40
5.
...to have a door strike activation code be “7
Q
”
7
#40
This six digit number can be used to access the programming mode. The security code has been factory set to
845464
(V-I-K-I-N-G). It is recommended that you change the security code to a personal 6 digit number. To
change the security code, access programming (see
Programming
section
A
). Enter six digits 0-9 followed by
#47
. If you have forgotten your security code, follow the steps in
Programming
section
A, 1. Accessing the
Programming Mode Locally
.
Note:
The security code must be six digits in length and can NOT contain a
Q
or #.
The door strike activation code turns on the door strike relay for the programmed door strike activation time. The
code can be entered while the phone is connected to a doorbox. The factory default activation code is “
”. This
can be changed to a different one or two-digit code. If a single-digit code is chosen, the available digits are 0-9.
If a two-digit code is used the digits can be 0-9 and/or “
Q
”. Programming a “
Q
” reguires entering a “
” when in
the programming mode. Note that the other commands listed in
Operation
section
D (Doorbox Controller
Features)
remain the same, so do not program the door strike activation code to be the same as one of the other
codes.
E. Security Code
B. Quick Programming Features
Description
Enter Digits
+ Location
Camera 1 and 2 output disconnected (factory default) .....................................................
01
+
#04
Output camera 1 ...................................................................................................................
02
+
#04
Continue to output video from last camera activated .............................................................
03
+
#04
Sequenced video from camera 1 and 2 (rotates every 4 seconds) .......................................
04
+
#04
* Note:
Multiple modes may be selected. Except
Q
4
and
Q
5
which can not be used together.
*
* Note:
Not compatible with Analog PABX/KSU Station mode
.
Description
Enter Digits
+
Location
Door strike 1 activation time .5 - 10 seconds (00 = .5 seconds/factory default)
2 digits
(00-10)
+
#01
Door strike 2 activation time .5 - 10 seconds (00 = .5 seconds/factory default)
2 digits
(00-10)
+
#02
Door Strike Activation Code (factory set to
)
1 digits
(0-9)
+
#40
2 digits
(0-9 ,
Q
)
+
#40
Security Code (factory set to 845464)
6 digits
(0-9)
+
#47
Disable special modes (
Q
1 -
Q
6
and
Q
8 -
Q
9
) listed below (factory default)
Q
0
* Doorbell mode
Q
1
* Custom ring mode
Q
2
* Multiple relay activation mode
Q
3
* Paging mode (not for use with
SLP-1
, see
Programming
section
G
)
Q
4
* Analog PABX/KSU station mode
Q
5
* Inhibit latching commands mode
Q
6
Auxiliary contact mode
(disables CCTV video control mode, factory default)
Q
7
+
#03
Auxiliary contact activation time .5-10 seconds (00 = .5 seconds/factory default)
2 digits
(00-10)
+
#03
Auxiliary contact latched while either doorbox is activated
11
+
#03
**
Auxiliary contact activated in custom ring cadence
12
**CCTV video control mode
(disables auxiliary contact mode)
Q
8
Inhibit auxiliary ring cadence mode (useful with
SLP-1
)
Q
9
To enter a single
Q