Warranty

12

IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666

Our Technical Support Department is available for assistance Monday through Friday 8am - 5pm central time. So that we can give you better service, before you call please:

1.

Know the model number, the serial number and what software version you have (see serial label).

2. 

Have your Product Manual    in front of you.

3. 

It is best if you are on site.

RETURNING PRODUCT FOR REPAIR

The following procedure is for equipment that needs repair:
1. 

Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem,

with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.

2. 

Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag,

sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or
freight collect shipments cannot be accepted. Ship cartons prepaid to:  

Viking Electronics, 1531 Industrial Street,  Hudson, WI  54016

3.

Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.

4.

RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned. 

RETURNING PRODUCT FOR EXCHANGE

The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1.  

Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.

2. 

If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return Authorization (R.A.) number will be issued.

This number is valid for fourteen (14) calendar days from the date of issue.

3. 

After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the Viking product using the same R.A. number.

4.  The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in 1, 2 and 3, be aware that you will have to
pay a restocking charge. 

TWO YEAR LIMITED WARRANTY

Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of

purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016.  Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a
Return Authorization (R.A.) number.

This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage

caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments.
This warranty does not cover stainless steel surfaces that have not been properly maintained.

NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS

ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER

PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE
PRODUCT SOLD HEREUNDER.

EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT

LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT
VIKING'S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.

IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF

WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY
OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED
AS SUCH.

If trouble is experienced with the C-1000B, for repair or warranty information, please
contact: 

Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016  (715) 386-8666

If the equipment is causing harm to the telephone network, the telephone company
may request that you disconnect the equipment until the problem is resolved.

Connection to Party Line Service is subject to State Tariffs. Contact the state public
utility commission, public service commission or corporation commission for information.

WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST
CALLS TO EMERGENCY NUMBERS:

Remain on the line and briefly explain to the dispatcher the reason for the call. Perform
such activities in the off-peak hours, such as early morning or late evenings.

It is recommended that the customer install an AC surge arrester in the AC outlet to
which this device is connected. This is to avoid damaging the equipment caused by
local lightning strikes and other electrical surges.

PART 15 LIMITATIONS

This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.

FCC REQUIREMENTS

This equipment complies with Part 68 of the FCC rules and the requirements adopted by the
ACTA. On the side of this equipment is a label that contains, among other information, a
product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be
provided to the telephone company.

The REN is used to determine the number of devices that may be connected to a telephone
line. Excessive REN's on a telephone line may result in the devices not ringing in response
to an incoming call. In most but not all areas, the sum of the REN's should not exceed five
(5.0) To be certain of the number of devices that may be connected to a line, as determined
by the total REN's, contact the local telephone company. For products approved after July
23, 2001, the REN for this product is part of the product identifier that has the format
US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point
(

e.g

., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.

The plug used to connect this equipment to the premises wiring and telephone network must
comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. If your
home has specially wired alarm equipment connected to the telephone line, ensure the
installation of this C-2000B does not disable your alarm equipment. If you have questions
about what will disable alarm equipment, consult your telephone company or a qualified
installer.

If the C-1000B causes harm to the telephone network, the telephone company will notify you
in advance that temporary discontinuance of service may be required. But if advance notice
isn't practical, the telephone company will notify the customer as soon as possible. Also, you
will be advised of your right to file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations, or
procedures that could affect the operation of the equipment. If this happens, the telephone
company will provide advance notice in order for you to make the necessary modifications
to maintain uninterrupted service.

Summary of Contents for C-1000B

Page 1: ...om Information 715 386 8861 VIKING Allows two Viking doorboxes or Viking paging amplifiers to share a single telephone line with a residential or business telephone system Programmable door strike act...

Page 2: ...nput CCTV Video 2 Input CCTV Video Output Signal Ground Signal Ground Signal Ground N C N O COM Auxiliary Contact Output Power LED Lights while unit is powered Door Strike 1 LED Lights while doorstrik...

Page 3: ...LOSURE INPUT DOORBOX 1 DOORBOX 2 8 9 10 11 DOORBOX PWR OUTPUT 12 13 DOOR STRIKE 1 N O COM N C 17 18 19 DOOR STRIKE 2 N O COM N C Ground Signal Ground Signal Signal Ground ON 1 2 3 ON 1 2 ON 1 2 3 ON 1...

Page 4: ...to 3 8 Ohm Speakers or Paging Horns optional Page Input Multi Zone Controller Amplifier Page Trigger Control Input DOOR BELL SW INPUT LOUD RING ENABLE I O COM ON 1 2 3 PWR PAGE MUTE PAGE TRIG OUT C O...

Page 5: ...ep 2 Connect doorboxes and doorstrike outputs if required as shown in section A Step 3 See Operation section E Keyless Entry Postal Lock D Using the C 1000B with Keyless Entry Proximity Card Reader or...

Page 6: ...ator to Video Out and program the C 1000B with Q7 and 11 03 3 Once the Analog PBX KSU Station Mode Q5 has been programmed you are not able to access the programming mode of the C 1000B in the normal f...

Page 7: ...Step 4 A double beep will indicate that you have accessed the programming mode Step 5 You can now Touch Tone program the features listed in Programming section B Step 6 When finished hang up both phon...

Page 8: ...ther commands listed in Operation section D Doorbox Controller Features remain the same so do not program the door strike activation code to be the same as one of the other codes E Security Code B Qui...

Page 9: ...that come before the timer is up are ignored by the C 1000B Touch tones that come after the timer is up are detected and acted on by the unit For this reason it is important to keep in mind that touch...

Page 10: ...or hook flash 2 times Monitor doorbox 1 1 Monitor doorbox 2 2 Note When on the C O line if a Touch Tone other than is entered any additional Touch Tones in that dial string will be ignored To regain...

Page 11: ...doorbox 1 or doorbox 2 is activated A momentary activation a continuous activation while the doorbox is in use and a ring cadence pattern are available Note The auxiliary contact mode Q7 is disabled w...

Page 12: ...R USE OF THE PRODUCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OTHER LEGAL THEORY ANY LIAB...

Reviews: