background image

13

12

CUSTOM WOOD FRAME INSTALLATION (DFUW Model) (cont.)

Top hinge pin

Top hinge

Figure 6

Right Hand

hinges shown

Top door hinge
adapter

Top hinge adapter
bushing

Bottom door
hinge adapter

Bottom hinge
adapter bushing

Bottom hinge
with cam

Bottom hinge pin

LEG LEVELER INSTALLATION

R

Re

ea

ad

d  B

Be

effo

orre

e  IIn

nsstta

alllliin

ng

g  L

Le

eg

g  L

Le

evve

elle

errss

1.  Four leveling legs are pre-installed in the base of the unit at the factory.

2.  The unit should be leveled from front to back and side to side. If floor

conditions do not allow the unit to sit level, adjust the leg levelers by turning
the required leg leveler counter-clockwise to increase the height and clockwise
to reduce the height.

WARNING

Do not lay unit on top, side, back, or front.  If unit is accidentally laid in
any position other than right side up, then the unit must remain in the
upright position for at least 24 hours before plugging the unit in.

CUSTOM WOOD FRAME INSTALLATION (DFUW Model) (cont.)

Clearance hole through
door gasket channel

#8 Wood Screw

Back of door

Figure 5

Step 9: Secure overlay panel to the door

With the #8 wood screws provided, fasten the overlay panel to the door. (See Figure 5).

Step 10: Install lock cam

Attach the lock cam to the back of the lock assembly with the Phillips head machine screw provided. Orient the lock
cam vertically when installing on the lock. 

Step 11: Install door gasket

Press the door gasket into the door channel. Make certain the gasket corners are fully inserted. If applicable insert the
key into the lock and make certain the lock operates properly.

Step 12: Install the door

Install the top and bottom hinge adapter bushings back into the hinge adapters that were removed in Step 6. Install
the door by reversing the procedure from Step 2. Install the top hinge pin so the screw head is flush with the top
surface of the hinge. If applicable insert key into lock and verify the lock cam works properly with the catch bracket on
the front of the refrigerator cabinet.

Figure 4

Summary of Contents for 24"W

Page 1: ...ation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Use Installation Guide Un...

Page 2: ...and grounding A 115V 60 Hz 15 amp fused electrical supply is required NOTE Time delay fuse or circuit breaker is recommended not used by anyone unable to operate it properly used only for its intended...

Page 3: ...C 60 Hz Maximum amps 3 0 Approximate Shipping Weight 110 lbs 49 5 kg 23 5 8 60 0 cm 21 3 16 53 8 cm 30 3 4 78 1 cm 14 3 4 37 5 cm 14 3 4 37 5 cm 14 3 4 37 5 cm 34 1 4 87 0 cm min to 35 88 9 cm max wit...

Page 4: ...aximum amps 3 3 Approximate Shipping Weight Single Zone 140 lbs 63 2 kg Dual Zone 170 lbs 76 5 kg SPECIFICATIONS DIMENSIONS DESIGNER 24 W Models Basic Electric Data 115 VAC 60 Hz Maximum amps 3 3 Appr...

Page 5: ...side to side Use a 5 32 allen wrench for this procedure See Figure 1 below Figure 1 9 32 7 mm Door must be parallel to top and sides of refrigerator Hinge adaptor screws Loosen these to adjust door on...

Page 6: ...6 1 cm Table A Glass Door Models 1 23 32 38 8 cm Material Type Hardwood 3 32 2 4 mm Diameter Pilot Hole Softwood 5 64 2 0 mm Diameter Pilot Hole Table B 8 Wood Screw Step 7 Mark and drill lock hole Lo...

Page 7: ...hours before plugging the unit in CUSTOM WOOD FRAME INSTALLATION DFUW Model cont Clearance hole through door gasket channel 8 Wood Screw Back of door Figure 5 Step 9 Secure overlay panel to the door W...

Page 8: ...screwdriver and plug the light unit in Plug Hex head screw Light assembly Green ground wire Hex head screw DANGER ELECTRICAL SHOCK HAZARD Failure to to disconnect the power cord when changing the lig...

Page 9: ...LIGHT 55 F 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C LIGHT 55 F 13 C 38 F 4 C SA ON OFF SET WARMER COLDER F C LIGHT 55 F 13 C 38 F 4 C SA 17 Glass Door Single Zone Models ON OFF SET PRESS AND HOL...

Page 10: ...l TruProtect must be Enabled See Disable Enable TruProtect described below Close door to reset DOOR AJAR Alarm Press the key to reset all other alarms Press and hold the key for five 5 seconds to enab...

Page 11: ...e single bottle roll out rack allows easy view and access of your inventory without disturbing other bottles Front Bottles Necks Facing Rear Rear Bottles Necks Facing Front LOADING RECOMMENDATIONS 24...

Page 12: ...ger when maintained properly and kept clean Condenser The condenser tubing inside the cabinet does not require frequent cleaning however satisfactory cooling depends on adequate ventilation over the c...

Page 13: ...o ow we er r O On n R Re es se et t P PO OR R i i e e d di is sc co on nn ne ec ct t a an nd d r re ec co on nn ne ec ct t t th he e p po ow we er r s su up pp pl ly y t to o u un ni it t E Ex xi it t...

Page 14: ...on nt ta ac ct t y yo ou ur r D De ea al le er r o or r V Vi ik ki in ng g C Cu us st to om me er r S Se er rv vi ic ce e t to o s sc ch he ed du ul le e s se er rv vi ic ce e b by y a a q qu ua al l...

Page 15: ...reach of contract or otherwise Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Owner shall...

Page 16: ...proper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to dama...

Reviews: