background image

 

 

 

 

Manual 

11/29/2018 

PSFEM6xxxxZxxx 

Viking Technology 

Revision G 

 

Page 30 of 41 

www.vikingtechnology.com 

 

5.1.6  Power Management Command Set 

SSD supports the Power Management command set consisting of: 

  Check Power Mode 

  Idle 

  Idle Immediate 

  Sleep 

  Standby 

  Standby Immediate 

  Slumber 

  Partial Mode 

5.1.7  Security Mode Feature Set 

SSD supports the Security Mode command set consisting of: 

  Security Set Password (OPCODE: F1h) 

  Security Unlock (OPCODE: F2h) 

  Security Erase Prepare (OPCODE: F3h) 

  Security Erase Unit (OPCODE: F4h) 

  Security Freeze Lock (OPCODE: F5h) 

  Security Disable Password (OPCODE: F6h) 

  Standby Immediate 

Summary of Contents for VPFEM6008GZCWMTL

Page 1: ...hnology Revision G Page 1 of 41 www vikingtechnology com SATA 6Gb s M 2 SATA Manual M 2 SATA is a non volatile solid state storage device delivering Serial ATA performance reliability and ruggedness f...

Page 2: ...PN s performance block diagram TBW power consumption Add VPFEM6030GZCDMTL 3 19 17 B Add performance TBW power for new PNs VPFEM6008GZCWMTL VPFEM6016GZCDMTL VPFEM6032GZCDMTL 7 24 17 C Add IOPS and MB...

Page 3: ...term or condition of any kind either expressed or implied including but not limited to expressed and implied warranties of merchantability fitness for a particular purpose and non infringement While...

Page 4: ...CAMTL 42 SATA 6GB Client 120 MLC 0 to 70 TSB 15nm MLC VPFEM6128GZCAMTL 42 SATA 6GB Client 128 MLC 0 to 70 TSB 15nm MLC VPFEM6240GZCZMTL 42 SATA 6GB Client 240 MLC 0 to 70 TSB 15nm MLC VPFEM6256GZCZMTL...

Page 5: ...com Client SSD s Viking s client SSD contains sophisticated provisions to protect firmware and data from corruption due to unexpected power loss However should power fail unexpectedly in flight write...

Page 6: ...STANDBY IMMEDIATE Command 15 2 4 Electrical Characteristics 15 2 4 1 Absolute Maximum Ratings 15 2 4 2 Supply Voltage 17 2 4 3 Supply Current 18 2 4 4 Power Consumption 18 2 5 Environmental Condition...

Page 7: ...l Feature Command Set 28 5 1 3 Device Configuration Overlay Command Set 29 5 1 4 General Purpose Log Command Set 29 5 1 5 Host Protected Area Command Set 29 5 1 6 Power Management Command Set 30 5 1 7...

Page 8: ...____ 18 Table 2 12 Temperature and Altitude Related Specifications___________________________ 19 Table 2 13 Shock and Vibration Specifications______________________________________ 20 Table 2 14 Relia...

Page 9: ...sh environments such as shock vibration humidity altitude ESD and extreme temperatures 1 1 Features The SSD delivers the following features Offers seamless SATA Revision 3 0 interface support for SATA...

Page 10: ...8 PSFEM6xxxxZxxx Viking Technology Revision G Page 10 of 41 www vikingtechnology com 1 2 Block Diagram Figure 1 1 High Level Block Diagram Notes 1 Support for up to 2 channels and 2 CE in the NAND Fla...

Page 11: ...n revision 3 0 that supports SATA up to 6 Gbps The SATA interface connects the host computer to the SSD subsystem The SATA interface runs at a maximum speed of 6 Gbps Giga bits per second If the host...

Page 12: ...LBA count Raw Capacity GB User Capacity GB LBA Count 8 8 15 649 200 16 14 27 370 224 16 16 31 277 232 32 30 58 626 288 32 32 62 533 296 64 60 117 231 408 64 64 125 045 424 128 120 234 441 648 128 128...

Page 13: ...1 165 1 535 4 9 480 512GB 256GBx2 BGA TSB 15nm 560 465 560 540 1 425 1 740 4 9 Notes Performance measured using CrystalDiskMark Performance may vary from flash configuration SDR configuration and plat...

Page 14: ...R cache 3 Tested with VPFEM5256GZIAMTL Toshiba MLC L die 4 Random IOPS cover the entire range of legal logical block addresses LBA s Measurements are performed on a full drive all LBA s have valid con...

Page 15: ...king SSD Benchmarking Methodology 2 3 Timing 2 3 1 STANDBY IMMEDIATE Command The Power On to Ready time assumes a proper shutdown power removal preceded by STANDBY IMMEDIATE command A STANDBY IMMEDIAT...

Page 16: ...Manual 11 29 2018 PSFEM6xxxxZxxx Viking Technology Revision G Page 16 of 41 www vikingtechnology com Description Min Max Unit Maximum Voltage Range for Vin 0 2 6 V Maximum Temperature Range 40 85 C...

Page 17: ...xxxxZxxx Viking Technology Revision G Page 17 of 41 www vikingtechnology com 2 4 2 Supply Voltage The operating voltage is 3 3V Table 2 8 Operating Voltage Description Min Max Unit Operating Voltage f...

Page 18: ...ed from the SATA 3 3V rail Table 2 10 Typical Power Consumption at 3 3V using MLC NAND Capacit y Flash Structur e Flash Type Rea d Writ e Partia l Slumbe r Idle DEVSL P 8GB 8GB x 1 TSOP TSB 15nm 830 7...

Page 19: ...GB 128GBx2 BGA TSB Bics2 550 490 560 540 1 400 1 700 4 9 30 32GB 32GBx1 TSOP TSB Bics3 300 125 560 540 950 850 4 9 60 64GB 32GBx2 TSOP TSB Bics3 550 255 560 540 1 215 1 020 4 9 120 128GB 64GBx2 TSOP T...

Page 20: ...environmental specification for shock and vibration Table 2 13 Shock and Vibration Specifications Stimulus Description Shock 500G 2ms Vibration 20 80 Hz 1 52mm 80 2000 Hz 20G X Y Z axis 30 min for ea...

Page 21: ...ited Write Endurance Capacity TBW 8GB 12 TBW 16GB 23 TBW 32GB 45 TBW 64GB 90 TBW 128GB 181 TBW 256GB 262 TBW 512GB 544 TBW Data retention 90 days at NAND expiration NOTES 1 Samples were built using To...

Page 22: ...ngtechnology com 3 Mechanical Information 3 1 Dimensions Figure 3 1 Dimensions d Notes 1 All dimensions are in millimeter General tolerance is 0 15 PCB thickness 0 8 0 08 2 Refer to Ordering Informati...

Page 23: ...www vikingtechnology com Figure 3 2 Dimension Details for M 2 42mm length Notes 1 All dimensions are in millimeter General tolerance is 0 15 PCB thickness 0 8 0 08 2 Refer to Ordering Information tabl...

Page 24: ...Manual 11 29 2018 PSFEM6xxxxZxxx Viking Technology Revision G Page 24 of 41 www vikingtechnology com 3 2 Card Edge Detail Figure 3 3 Dimension Details for M 2 card edge...

Page 25: ...Manual 11 29 2018 PSFEM6xxxxZxxx Viking Technology Revision G Page 25 of 41 www vikingtechnology com Figure 3 4 Dimension Details for M 2 connector and notch Key notch detail...

Page 26: ...scription Pin 74 3 3V CONFIG_2 GND 75 72 3 3V GND 73 70 3 3V GND 71 68 SUSCLK 32kHz I 0 3 3V CONFIG_1 GND 69 66 Module Key N C 67 64 Module Key Module Key 65 62 Module Key Module Key 63 60 Module Key...

Page 27: ...appropriate operating system OS support as described in the SATA 2 6 specification This product supports Asynchronous Signal Recovery and will issue an unsolicited COMINIT when first mated with a powe...

Page 28: ...max address F8h Write FPDMA QUEUED 61h Read native max Ext 27h Write Log Ext 3Fh Read sector s w o retry 21h Write multiple C5h Read sector s w retry 20h Write multiple Ext 39h Read sector s Ext 24h W...

Page 29: ...t SSD supports the Device Configuration Overlay command set consisting of Device Configuration Freeze Lock Device Configuration Identity Device Configuration Restore Device Configuration Set 5 1 4 Gen...

Page 30: ...of Check Power Mode Idle Idle Immediate Sleep Standby Standby Immediate Slumber Partial Mode 5 1 7 Security Mode Feature Set SSD supports the Security Mode command set consisting of Security Set Passw...

Page 31: ...nt by the Compact Flash Association 9 X 0000h Retired 10 19 F Varies Serial number 20 ASCII characters 20 21 X 0000h Retired 22 X 0000h Obsolete 23 26 F Varies Firmware revision 8 ASCII characters 27...

Page 32: ...rial ATA definition 78 F 0014h Serial ATA features supported 79 V 0040H Serial ATA features enabled 80 F 01F8h Major Version Number 81 F 0000h Minor Version Number 82 F 346Bh Command set supported 83...

Page 33: ...119 F 4014h Supported settings 120 F 4014h Command set Feature Enabled Supported 121 126 F 0h Reserved 127 F 0h Removable Media Status Notification feature set support 128 V 0021h Security status 129...

Page 34: ...e 221 0h Reserved 222 F 107Fh Transport major version number 223 F 0h Transport minor version number 224 229 0h reserved 230 233 0h Extend number of user addressable sectors 234 0001h Minimum number o...

Page 35: ...ufacturers have adopted S M A R T to help warn system software a system administrator or a user of impending drive failure while time remains to take preventive action It provides the host system with...

Page 36: ...S M A R T disable operations DA S M A R T return status DB S M A R T enable disable automatic off line DC FF Reserved Vendor Specific Note that D1 D3 and D7 have been made obsolete in the ATA 8 speci...

Page 37: ...ad Failure Block Count E9h Lifetime Writes to Flash GB F1h Lifetime Writes from Host each G F2h Lifetime Reads from Host each G F3h Total internal copy ecc error count F4h Average erase count 4bytes F...

Page 38: ...3h 00h 64h 64h SSD life remaining Note 2 0 0 0 00h E8h 0Bh 00h 64h 64h Total Read bad Block Count 0 0 0 00h E9h 0Bh 00h 64h 64h Flash write 64GB each count 0 0 0 00h F1h 32h 00h 00h 00h Host write 64G...

Page 39: ...it S M A R T EXECUTION OFF LINE IMMEDIATE B0h D4h command per the ATA 8 specification This command causes the SSD to initiate the collection of S M A R T data in an off line mode and then preserves th...

Page 40: ...81h Execute S M A R T Short self test routine immediately in captive mode 82h Execute S M A R T Extended self test routine immediately in captive mode 84h Execute S M A R T Selective self test routin...

Page 41: ...Hard Disk Drive Hot Plug A term used to describe the removal or insertion of a SATA storage drive when the system is powered on IOPS Input output operations per second LBA Logical Block Address MB Me...