Specifi cations

Description

30” W. (76 cm) Wide

36” W. (91 cm) Wide

Overall width

29-7/8” (75.9 cm)

35-7/8” (91.1)

 Overall height from bottom
   To top of side panl
   Leg adjustment

35-7/8” (91.1 cm) min to 37” (94.0 cm) max

1-1/8” (2.9 cm)

Overall depth from rear
   To end of side panel
   To front of door
   To end of landing ledge
   To end of door handle   

24-5/16” (61.8 cm)

25-3/4” (65.4 cm)

28-1/16” (71.2 cm)

28-11/16” (72.9 cm)

*Add 3/4” (1.9 mc) to overall depth for ranges with a backguard or high shelf to allow for 

rear spacers when installed against a combustible wall.

Additions to Base Height

To top of island trim:  add 1” (2.5 cm)

To top of backguard - add 8” (20.3 cm)

To top of high shelf - add 23-1/2” (59.7 cm)

Gas requirements

Shipped Natural or LP/Propane, accepts standard residential 1/2” (1.3 cm) ID gas

service line. Unit is fi eld convertible with proper conversion kit

Electrical equirements

120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 

3-prong plug attached to unit

Maximum amp usage

.83 amps

1.5 amps

 Surface Burners   Natural/LP

15,000 BTU (4.4 kW)/1

3

,500 BTU (4.

3

 kW)

Broil Burner Natural/LP

18,000 BTU (5.3 kW)/16,000 BTU (4.7 kW)

Oven Burner Natural/LP

30,000 BTU (8.8 kW) Nat./LP

Oven interior width

23” (58.4 cm)

29” (73.7 cm)

Oven interior height

16-1/8” (40.9 cm)

Oven interior depth

Overall - 18-3/4” (47.6 cm)

Oven volume 
   Overall   
   AHAM

4.0 cu. ft.
3.7 cu. ft.

5.1 cu. ft.
5.1 cu. ft.

Approximate shipping weight

410 lbs. 

(184.5 kg)

500 lbs. 

(225 kg

Minimum clearances from adjacent combustible construction:
Below cooking surface (36” [91.4 cm] and below)
• Sides - 0”
• Top grate support - 36” (91.4 cm)
Above cooking surface (above 36” [91.4 cm])
• Sides - 8” (20.3 cm)
•  Within 8” (20.3 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm) above

cooking surface

• Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 3/4” (1.9 cm) with 8” backguard or high shelf to allow for rear spacers against a combustible rear wall;
• 6” (15.2 cm) with island trim against combustible rear wall

Summary of Contents for VGIC5302

Page 1: ...1 Installation GUIDE Professional Freestanding Open Burner Gas Ranges VGIC5302 VGIC5362...

Page 2: ...w to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others is very important We have provided many important safety message...

Page 3: ...local codes or in absence of codes with the National Electrical Code NEC ANSI NFPA 70 latest edition TIPPING HAZARD To reduce the risk of the appliance tipping it must be secured by a properly instal...

Page 4: ...4 0 cm max 1 2 5 cm 29 7 8 75 9 cm 35 7 8 91 1 cm 25 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49 2 cm 8 1 8 20 6 cm 26 7 16 67 2 cm 1 5 8 4 1 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 0 cm max 24 5 16 61 8 cm...

Page 5: ...wire cord with grounded 3 prong plug attached to unit Maximum amp usage 83 amps 1 5 amps Surface Burners Natural LP 15 000 BTU 4 4 kW 13 500 BTU 4 3 kW Broil Burner Natural LP 18 000 BTU 5 3 kW 16 000...

Page 6: ...requirement does not apply if a range hood is installed over the cooking surface 46 min 116 8 cm 13 max 33 0 cm 8 min 20 3 cm 18 min 45 7 cm 3 8 0 95 cm 36 91 4 cm A opening width BURN HAZARD To avoid...

Page 7: ...trim Important Clearances from non combustible materials are not part of the ANSI Z21 1 scope and are not certified by CSA Clearances to non combustible materials must be approved by the authority ha...

Page 8: ...emand External regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked...

Page 9: ...r grates and styrofoam off the top cooking surface Be sure to remove the burner caps packaged in styrofoam below the burner grates Do not discard the anti tip metal brackets supplied with the range Th...

Page 10: ...mended that a pallet or lift jack be used rather than tilting Raise unit about a foot Unscrew temporary legs from couplings Screw legs into couplings on all four corners Lower range gently to keep any...

Page 11: ...nly as the adjustment required may exceed the thread available in the leg Move unit into opening Check that unit is level side to side and front to back Side trim of the high corner must be 3 8 0 95 c...

Page 12: ...evice must be engaged properly to prevent product from tipping over WARNING 1 Measurement A Measurement A Measurement A Measurement A Measurement A 1 4 64 cm 1 4 64 cm Measurement A 1 2 1 3 cm B 2 Mea...

Page 13: ...ance in operation always check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company 1 1 8 1 8 32 cm 32 cm 1 8 32 cm 1 1 2 1 1 2 3 8 cm 3 8 cm 2 1 2 6...

Page 14: ...1 2 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm Slide range into place Be sure wall anti tip bracket slides into the anti tip opening or floor anti tip hook and bracket are engaged depending on the one used...

Page 15: ...ED SERVICE 111 Front Street Greenwood Mississippi 38930 Record the information indicated below You will need it if service is ever required You will first need to remove the left side surface burner g...

Page 16: ...Viking Range LLC 111 Front Street Greenwood Mississippi 38930 662 4551200 For more product information call 1 888 845 4641 or visit our website at www vikingrange com 069750 000 EN 060119...

Reviews: