background image

18

19

1

1

2

2

3

2

Reattach door to range.

Open door completely. Reattach hinge trim on both

sides.

3

4

Remove pins from holes in hinges.

Close door.

5

If the door needs to be adjusted, loosen hinge trim screws

located in step 2. Adjust the screws located between the
door and kickplate using a 5/32” hex head Allen wrench.

After adjustment, tighten hinge trim screws.

Door Replacement and Adjustment

1

2

3/8”

3/

8”

 

(0.95 cm)

(0.

95

 cm

)

3/8”

 

(0.95 cm)

3

Burner heads and burner caps are packed in the

cardboard top pack with the grates. Align burner head

on burner base. Place burner cap on burner head.

Place grate onto the burner pan.

Check that unit is level side to side

and front to back. The side trim must be 3/8” (0.95 cm)

above countertop. If unit is not level, repeat Steps 5-7

in “Leveling/Adjustments/Alignment” section.

Slide range into place. Be sure  

anti-tip bracket slides into the anti-tip opening.

Final Installation

Summary of Contents for RVGR

Page 1: ...reet Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Website at vikingrange com F21185 EN 053113 3 Series Freestanding 30 Gas Self Clean Se...

Page 2: ...ich COULD result in minor personal injury or property damage All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions a...

Page 3: ...hich can cause serious injury or death and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fu...

Page 4: ...im add 0 0 0 cm To top of backguard add 6 15 2 cm To top of high shelf add 18 3 16 46 2 cm Gas Requirements Shipped standard for Natural gas field convert with LP conversion kit included with each uni...

Page 5: ...result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation instructions for additional information These dimensions provide for safe and ef...

Page 6: ...nal regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked with a mano...

Page 7: ...may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or debris before being used then rinsed a...

Page 8: ...ing hardware 3 Screw legs into couplings on all four corners Leg Installation 1 2 Measure the four corners in cutout area to verify if flooring is level For uneven or sloped floors level unit with met...

Page 9: ...ays check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company Leveling Adjustments Alignments cont Connecting Gas Electric WARNING TIPPING HAZARD To...

Page 10: ...m screws Door Replacement and Adjustment 1 2 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm 3 Burner heads and burner caps are packed in the cardboard top pack with the grates Align burner head on burner base Pl...

Page 11: ...allation instructions should remain with the unit for future reference Service Registration Performance Checklist A qualified installer should carry out the following checks Check top burner ignition...

Page 12: ...______________________________________________________________________________________________________ Notes ___________________________________________________________________________________________...

Reviews: