
TECHNICAL SUPPORT 1 800 908 0884
28
Auto-Open Feature
SPECIAL FEATURES
SPECIAL FEATURES
Radio Station
Mag.
Lock
M
a
g
.
Lo
ck
Safety Connector
Open Commands
Guard Station
Master/Slave
Brake
UL
Siren
Radio
Rec.
UL
Sensor
O
P
E
N
R
IG
H
T
2
4
V
B
A
T
2
4
V
A
C
O
P
E
N
L
E
FT
Safety
Loop
Center
Loop
Obstruction
Sensor
Charger
Power
Low Battery
Motor Sensor
Hold Open
Timer
Stop
Overlap Delay
Close
Open
O
b
st
ru
ct
io
n
S
e
n
so
r
min.
MAX
O
ve
rl
a
p
D
e
la
y
1.
5
0
3
Radio Station
Loop Connector
Open Commands
Guard Station
Master/Slave
G
N
D
C
lo
se
S
to
p
O
p
e
n
G
N
D
C
lo
se
S
to
p
O
p
e
n
G
n
d
Fi
re
G
n
d
S
tr
ik
e
G
n
d
Ex
it
G
n
d
C
e
n
te
r
G
n
d
Re
op
en
G
n
d
U
L
G
n
d
+
2
8
v
G
n
d
R
a
d
io
G
n
d
+
2
8
v
+
2
8
v
M
a
g
.
Lo
ck
Fail
Safe/Secure
M
A
G
.
LO
C
K
N.C.
COM
N.O.
Charger
Power
Low Battery
Check Motor
H
o
ld
O
p
e
n
Ti
m
e
r
S
to
p
C
lo
se
O
p
e
n
3
0
6
0
O
ff
1
R
a
d
io
R
e
c.
U
L
S
e
n
s
R
e
o
p
e
n
Lo
o
p
C
e
n
te
r
Lo
o
p
B
ra
ke
Si
re
n
JP3
C35 C36
Radio Station
Mag.
Lock
M
a
g
.
Lo
ck
Safety Connector
Open Commands
Guard Station
Master/Slave
Brake
UL
Siren
Radio
Rec.
UL
Sensor
O
P
E
N
R
IG
H
T
2
4
V
B
A
T
2
4
V
A
C
O
P
E
N
L
E
FT
Safety
Loop
Center
Loop
Obstruction
Sensor
Charger
Power
Low Battery
Motor Sensor
Hold Open
Timer
Stop
Overlap Delay
Close
Open
O
b
st
ru
ct
io
n
S
e
n
so
r
min.
MAX
O
ve
rl
a
p
D
e
la
y
1.
5
0
3
Radio Station
Loop Connector
Open Commands
Guard Station
Master/Slave
G
N
D
C
lo
se
S
to
p
O
p
e
n
G
N
D
C
lo
se
S
to
p
O
p
e
n
G
n
d
Fi
re
G
n
d
S
tr
ik
e
G
n
d
Ex
it
G
n
d
C
e
n
te
r
G
n
d
Re
op
en
G
n
d
U
L
G
n
d
+
2
8
v
G
n
d
R
a
d
io
G
n
d
+
2
8
v
+
2
8
v
M
a
g
.
Lo
ck
Fail
Safe/Secure
M
A
G
.
LO
C
K
N.C.
COM
N.O.
Charger
Power
Low Battery
Check Motor
H
o
ld
O
p
e
n
Ti
m
e
r
S
to
p
C
lo
se
O
p
e
n
3
0
6
0
O
ff
1
R
a
d
io
R
e
c.
U
L
S
e
n
s
R
e
o
p
e
n
Lo
o
p
C
e
n
te
r
Lo
o
p
B
ra
ke
Si
re
n
JP3
C35 C36
The Auto-Open feature in Viking Gate Operators enables the following functionality in
the event of power failure:
a) Open the gate in case of power failure (120 or 220 VAC).
b) Keep the gate at the open position as long as the there is no power.
c) Resume to normal operation when the power has been restored.
The Auto-Open feature allows proper operation while opening in case of power failure
for the following devices:
• All accessories,
• All safety devices,
• All entrapment protections.
The only operation that can not be executed while opening in case of power failure is to
CLOSE the gate.
To enable the Auto-Open feature : Use the
“jumper” provided and place it on the pin-
header of JP3, on the terminals close to C35 as
the illustration indicates.
Once you put the “jumper” on the control
board the “Check Motor” light will come on
indicating that the Auto-Open feature has been
enabled.
N
NO
OT
TE
E –
– T
Th
hiiss ffe
ea
attu
urre
e d
do
oe
ess n
no
ott w
wo
orrk
k w
wiitth
h tth
he
e
M
Ma
asstte
err//S
Slla
avve
e C
Ciirrccu
uiitt B
Bo
oa
arrd
d