perform the charging system test.
CRANKING VOLTS LOW
The cranking voltage is below
normal limits, troubleshoot the
starter with manufacturers
recommended procedure.
CRANKING VOLTS
××.××V LOW
CRANKING VOLTS NOT
DETECTED
CRANKING VOLTS
NOT DETECTED
The cranking voltage is not
detected.
4.
If the cranking voltage is
normal, press
«ENTER»
to
begin charging system test.
PRESS ENTER FOR
CHARGING TEST
5.
Press the
«ENTER»
key, you
will view the following screen:
6.
Press the
«ENTER»
key, one
of the three results will be
displayed along with the actual reading measured.
LOW CHARGING VOLTS WHEN TEST AT IDLE
The generator is not providing
sufficient current to the battery.
Check the belts to ensure the
generator is rotating with
engine running. If the belts are slipping or broken, replace
the belts and retest. Check the connections from the
generator to the battery. If the connection is loose or heavily
corroded, clean or replace the cable and retest. If the belts
and connections are in good condition, replace the
generator.
CHARGING SYSTEM NORMAL WHEN TEST AT IDLE
The system is showing
normal output from the
MAKE SURE ALL
LOADS ARE OFF
ALT. IDLE VOLTS
××.××V LOW
ALT. IDLE VOLTS
××.××V NORMAL