![background image](http://html.mh-extra.com/html/viewsonic/vlcds25973-4w/vlcds25973-4w_service-manual_1021324037.webp)
Troubleshooting:
1.
If the firmware upgrade fails at the last step,
don’t unplug the power cord of the monitor
. Just try the upgrade
procedure again.
(a)
If there is error to execute the command at or before line10 in the “bdisp.txt” batch file (for instance, the
message “Error executing batch file at line 4” shows up in the Gprobe program (see the following picture)),
please try to upgrade the firmware again.
Test failed.
Test failed.
Test failed.
Test failed.
Test failed.
Test failed.
Error executing batch file at line 4.
Execution time: 5.72s
GProbe:>
(b)
If there is error to execute the command at or after line11 in the “bdisp.txt” batch file, please copy the error
line of the “bdisp.txt” batch file to “Gprobe:>” in the Gprobe program, and then press “Enter.” For example,
there is “Error executing batch file at line 16” (see the following picture). Then you have to copy line 16
“FLASHWRITE C:\VP912b\VP912_AU_V2_001_040611.bin” in the “bdisp.txt” file to “Gprobe:>” in the
Gprobe program, and then press “Enter” (see the picture next page).