![background image](http://html1.mh-extra.com/html/viewsonic/va1721wmb-17-lcd-monitor/va1721wmb-17-lcd-monitor_service-manual_1020659025.webp)
- 25 –
ViewSonic Corporation
Confidential - Do Not Cop
VA1721wmb
(4)
、
Adjust the RED of color3 on factory window until CA-210 indicator reached the
value R=100
(5)
、
Adjust the GREEN of color3 on factory window until CA-210 indicator reached the
value G=100
(6)
、
Adjust the BLUE of color3 on factory window until CA-210 indicator reached the
value B=100
(7)
、
Repeat above procedure ( item 4,5,6) until CA-210 RGB value meet the
tolerance =100
±
5
D
、
Adjust 5400 color-temperature
(1) Switch the CA-210 to
RGB-Mode
(with press “MODE” button )
(2)
、
Switch the MEM .channel to Channel 1( with up or down arrow on CA-210 )
(3)
、
The LCD-indicator on CA-210 will show x=0.335
±
0.03, y=0.350
±
0.03, Y
≥
190 cd/m
2
(4)
、
Adjust the RED of color3 on factory window until CA-210 indicator reached the
value R=100
(5)
、
Adjust the GREEN of color3 on factory window until CA-210 indicator reached the
value G=100
(6)
、
Adjust the BLUE of color3 on factory window until CA-210 indicator reached the
value B=100
(7)
、
Repeat above procedure ( item 4,5,6) until CA-210 RGB value meet the
tolerance =100
±
5
E
、
Adjust SRGB color-temperature
(1)
、
Switch the CA-210 to
RGB-Mode
(with press “MODE” button )
(2)
、
Switch the MEM .channel to Channel 1 ( with up or down arrow on CA-210 )
(3)
、
The LCD-indicator on CA-210 will show x=0.313
±
0.03, y=0.329
±
0.03, Y
≥
190 cd/m
2
(4)
、
Adjust the RED of color3 on factory window until CA-210 indicator reached the
value R=100
(5)
、
Adjust the GREEN of color3 on factory window until CA-210 indicator reached the
value G=100
(6)
、
Adjust the BLUE of color3 on factory window until CA-210 indicator reached the
value B=100
(7)
、
Repeat above procedure ( item 4,5,6) until CA-210 RGB value meet the tolerance
=100
±
5
F
、
Press reset key and Turn the Power-button “off to on” to quit from factory mode.
2. Geometry
1).Set cross-hatch pattern and preset timing as timing table listed.
2).Change to each mode in turn and wait for the monitor finish auto-alignment and save
press before change to next mode.
3).Until all of modes are adjusted, exit OSD menu and press POWER OFF to exit factory
mode.
Summary of Contents for VA1721wmb - 17" LCD Monitor
Page 22: ...22 ViewSonic Corporation Confidential Do Not Cop VA1721wmb Block Diagram...
Page 36: ...36 ViewSonic Corporation Confidential Do Not Cop VA1721wmb...
Page 38: ...38 ViewSonic Corporation Confidential Do Not Cop VA1721wmb...
Page 41: ...41 ViewSonic Corporation Confidential Do Not Cop VA1721wmb 5 7 Packing Procedure...
Page 42: ...42 ViewSonic Corporation Confidential Do Not Cop VA1721wmb 6 Troubleshooting Flow Chart...
Page 56: ...56 ViewSonic Corporation Confidential Do Not Cop VA1721wmb Packing For Shipping...
Page 60: ...60 ViewSonic Corporation Confidential Do Not Cop VA1721wmb Picture 19...
Page 61: ...61 ViewSonic Corporation Confidential Do Not Cop VA1721wmb 10 Block Diagram...
Page 71: ...71 ViewSonic Corporation Confidential Do Not Cop VA1721wmb 12 2 MAIN BOARD PCB BUTTON VIEW...
Page 72: ...72 ViewSonic Corporation Confidential Do Not Cop VG1721wm VA1721wm 12 3 POWER PCB TOP VIEW...
Page 73: ...73 ViewSonic Corporation Confidential Do Not Cop VG1721wm VA1721wm 12 4 POWER PCB BUTTON VIEW...
Page 75: ...75 ViewSonic Corporation Confidential Do Not Cop VA1721wmb 12 7 POWER PCB TOP BUTTON VIEW Q...